Use the tables below to locate the System Reference Code (SRC) that you have displayed. In the table, xxxx can be any number 0 through 9 or letter A through F.
The SRCs are grouped in ranges, although the recovery for each range might not apply to every SRC within the range. If you cannot find your SRC range in this table, call your next level of support.
The codes in this list are organized by their first character, with numbers coming before letters. To navigate this listing, click or go to the number or letter below that matches the first character of your SRC. Then, select your SRC from the list provided.
For each SRC range, there will be a brief description of what the SRC range indicates, and what you should do. If the recommendation does not solve the problem, or if there is no recommended way to solve the problem, contact your hardware service provider.
SRC | What it means, and what you should do |
---|---|
0000 xxxx | Check for a specific 0000 SRC below. If you do not see your SRC below, a control panel failure may have been detected. |
0000 AABB 0000 AACC |
You attempted a timed, remote, or automatic Initial
Program Load (IPL) with the system in the Secure or Manual mode. Perform the following steps: Set the system to the Normal or Auto mode and perform an IPL again. |
0000 AADD | You attempted a manual IPL with the system in the Secure
or Auto mode. Set the system to the Normal or Auto mode and perform an IPL again. |
SRC | What it means |
---|---|
1xxx xxxx | Check for a specific 1xxx SRC below. If you do not see your SRC below, a System Power Control Network (SPCN) failure may have been detected. |
1xxx D101 1xxx D102 |
Either a battery power unit x failed, or a battery power
unit x test failed. Replace the battery power unit. See Replace the battery power unit on Models 5xx and expansion units FC 507x and FC 508x. If the battery still does not work after the replacement, call your hardware service provider. |
SRC | What it means |
---|---|
2105 xxxx | It may indicate a disk unit failure. |
2107 xxxx | It may indicate a disk unit failure. |
2629 xxxx | It may indicate a Storage IOA failure. |
2644 3136 | It may indicate a software installation error. See Common SRCs for software installation for more information. |
2718 xxxx | It may indicate a Storage IOA failure. |
2724 xxxx | It may indicate an I/O adapter Licensed Internal Code, or incompatible hardware failure. |
2726 xxxx | It may indicate a Storage IOA failure. |
2728 xxxx | It may indicate a Storage IOA failure. |
2729 xxxx | It may indicate a Storage IOA failure. |
2740 xxxx | It may indicate a Storage IOA failure. |
2741 xxxx | It may indicate a Storage IOA failure. |
2742 xxxx | It may indicate an I/O adapter hardware failure. |
2743 xxxx | It may indicate an I/O adapter hardware failure. |
2744 xxxx | It may indicate an I/O adapter Licensed Internal Code, or incompatible hardware failure. |
2745 xxxx | It may indicate an I/O adapter hardware failure. |
2746 xxx | It may indicate a Twinaxial - Workstation Adapter error. |
2748 xxxx | It may indicate a system bus failure. |
2749 xxxx | It may indicate an I/O processor configuration error. |
2750 xxxx | It may indicate an I/O adapter hardware failure. |
2751 xxxx | It may indicate an I/O adapter hardware failure. |
2757 xxxx | It may indicate a system bus failure. |
2760 xxxx | It may indicate an I/O adapter hardware failure. |
2761 xxxx | It may indicate an I/O adapter hardware error. |
2763 xxxx | It may indicate a system bus failure. |
2765 xxxx | It may indicate an I/O processor failure. |
2766 xxxx | It may indicate an I/O processor configuration error |
2767 xxxx | It may indicate an I/O processor error. |
2768 xxxx | It may indicate an I/O processor error. |
2771 xxxx | It may indicate an incompatible hardware detected, I/O adapter Licensed Internal Code failed, or one half of I/O adapter failed. |
2772 xxxx | It may indicate an incompatible hardware error, or I/O adapter Licensed Internal Code failure. |
2778 xxxx | It may indicate a system bus failure. |
2780 xxxx | It may indicate a system bus failure. |
2782 xxxx | It may indicate a system bus failure. |
2787 xxxx | It may indicate an I/O processor configuration error. |
2793 xxxx | It may indicate an I/O adapter hardware error. |
2805 xxxx | It may indicate an I/O adapter hardware error. |
2809 xxxx | It may indicate a Storage IOA failure. |
2810 xxxx | It may indicate a Storage IOA failure. |
281x xxxx | It may indicate an I/O adapter hardware error. |
2824 xxxx | It may indicate a Storage IOA failure. |
282C xxxx | It may indicate a Storage IOA failure. |
2838 xxxx | It may indicate an I/O adapter Licensed Internal Code failure. |
283C xxxx | It may indicate a device backplane problem. |
283D xxxx | It may indicate a device backplane problem. |
283F xxxx | It may indicate a device backplane problem. |
2842 xxxx | It may indicate an I/O processor error. |
2843 xxxx | It may indicate an I/O processor error. |
2844 xxxx | It may indicate an I/O processor error. |
2849 xxxx | It may indicate an I/O adapter Licensed Internal Code failure, or incompatible hardware error. |
284B xxxx | It may indicate an I/O processor error. |
284C xxxx | It may indicate an I/O processor error. |
284D xxxx | It may indicate an I/O processor error. |
284E xxxx | It may indicate an I/O processor error. |
286C xxxx | It may indicate an I/O processor error. |
286D xxxx | It may indicate an I/O processor error. |
286E xxxx | It may indicate an I/O processor error. |
286F xxxx | It may indicate an I/O processor error. |
287F xxxx | It may indicate an I/O adapter hardware error detected. |
28B9 xxxx | It may indicate an device backplane problem. |
28BC xxxx | It may indicate an device backplane problem. |
28CB xxxx | It may indicate an device backplane problem. |
28CC xxxx | It may indicate an device backplane problem. |
28CD xxxx | It may indicate an device backplane problem. |
SRC | What it means |
---|---|
3490 xxxx | It may indicate a tape unit problem. |
3494 xxxx | It may indicate a tape library problem. |
3570 xxxx | It may indicate a tape unit problem. |
358x xxxx | It may indicate a tape unit problem. |
3590 xxxx | It may indicate a tape unit problem. |
SRC | What it means |
---|---|
432x xxxx | It may indicate a disk unit failure. |
SRC | What it means |
---|---|
5306 xxxx | It may indicate a device backplane problem. |
5700 xxxx | It may indicate an I/O adapter hardware error. |
5701 xxxx | It may indicate an I/O adapter hardware error. |
5702 xxxx | It may indicate a problem with an I/O processor. |
5703 xxxx | It may indicate a system bus failure. |
5704 xxxx | It may indicate an I/O processor configuration error. |
SRC | What it means |
---|---|
6149 xxxx | It may indicate an I/O adapter Licensed Internal Code failure. |
63xx xxxx | A tape unit failed. See Recover from a tape or optical device problem. |
6532 xxxx | It may indicate a Storage IOA failure. |
6533 xxxx | It may indicate a Storage IOA failure. |
6534 xxxx | It may indicate a Storage IOA failure. |
660x xxxx | It may indicate a disk unit failure. |
671x xxxx | It may indicate a disk unit failure. |
671A xxxx | It may indicate a Storage IOA failure. |
673x xxxx | It may indicate a disk unit failure. |
6A59 xxxx | It may indicate a workstation adapter console failure. |
SRC | What it means |
---|---|
7207 xxxx | It may indicate a tape unit error. |
7208 xxxx | It may indicate a 8mm tape drive failure. |
SRC | What it means |
---|---|
93xx xxxx | A disk or diskette unit failed. See Recover from a disk or disk drive problem. |
8427 xxxx | It may indicate a tape library failure. |
SRC | What it means |
---|---|
A1xx xxxx | Check for a specific A1xx SRC below. If you do not see your SRC below, it can indicate an IPL load device failure. See Recover from IPL or system failures. |
A12x 19xx | It may indicate a software installation error. See Common SRCs for software installation for more information. |
A1xx 19xx | It may indicate a software installation error. See Common SRCs for software installation for more information. |
A6xx xxxx | Check for a specific A6xx SRC below. If you do not see your SRC below, it can mean a Licensed Internal Code error was detected. See Common SRCs for software installation for more information. |
A6xx 0277 | A compression disk unit cannot complete an operation.
|
A600 11xx | It may indicate a software installation error. See Common SRCs for software installation for more information. |
A6xx 500x | It may indicate a workstation controller failure. See Recover from a workstation failure. |
A600 50xx | It may indicate an Operations Console error. See Troubleshoot system reference code (SRC) data for Operations Console. |
A9xx xxxx | Check for a specific A9xx SRC below. If you do not see your SRC below, it may indicate an application error. |
A900 xxxx | It may indicate an Operations Console error. See Troubleshoot system reference code (SRC) data for Operations Console. |
A900 2000 | If the IPL completed normally, does the console have
a sign-on screen? Note: If the console did not vary on, see Recover when the console does not vary on.
|
SRC | What it means |
---|---|
B0xx xxxx | Check for a specific B0xx SRC below. If you do not see
your SRC below, it can mean a communications Licensed Internal Code failure
was detected.
|
B003 xxxx | It may indicate an asynchronous Communications failure. |
B006 xxxx | It may indicate a common Licensed Internal Code failure. |
B070 xxxx | It may indicate a no response, time-out temporary error. |
B1xx xxxx | Check for a specific B1xx SRC below. If you do not see your SRC below, it can mean an IPL load device failure. See Recover from IPL or system failures. |
B101 4500 | It may indicate an error with the Integrated xSeries® Server for iSeries™. See Common SRCs for software installation for more information. |
B1xx 45xx | It may indicate a software installation error. See Common SRCs for software installation for more information. |
B2xx xxxx | It may indicate a Logical partition error. See Logical partition SRC finder for more information. |
B350 420A | It may indicate a software installation error. See Common SRCs for software installation for more information. |
B427 xxxx | It may indicate a system processor failure. |
B428 xxxx | It may indicate a system processor failure. |
B437 xxxx | It may indicate a system processor failure. |
B448 xxxx | It may indicate a system processor failure. |
B467 xxxx | It may indicate a system processor failure. |
B4FF xxxx | It may indicate a system processor failure. |
B6xx xxxx | Check for a specific B6xx SRC below. If you do not see your SRC below, it can mean a Licensed Internal Code error was detected. |
B600 500x | It may indicate an Operations Console error. See Troubleshoot system reference code (SRC) data for Operations Console. |
B600 53xx | It may indicate a Logical partition error. See Logical partition SRC finder for more information. |
B608 1105 | It may indicate a software installation error. See Common SRCs for software installation for more information. |
B9xx xxxx | Check for a specific B9xx SRC below. If you do not see your SRC below, it can mean an i5/OS™ IPL failure. See Recover from IPL or system failures. |
B900 3121 | It may indicate a software installation error. See Common SRCs for software installation for more information. |
SRC | What it means |
---|---|
C1xx xxxx | These SRCs show the Status of an IPL. See the IPL SRC finder for details, then perform Recover from IPL or system failures. |
C2xx xxxx | These SRCs show the Status of an IPL. See the IPL SRC finder for details, then perform Recover from IPL or system failures. |
C3xx xxxx | These SRCs show the Status of an IPL. See the IPL SRC finder for details, then perform Recover from IPL or system failures. |
C5xx xxxx | These SRCs show the Status of an IPL. See the IPL SRC finder for details, then perform Recover from IPL or system failures. |
C6xx xxxx | These SRCs show the Status of an IPL. See the IPL SRC finder for details, then perform Recover from IPL or system failures. |
C9xx xxxx | These SRCs show the Status of an IPL. See the IPL SRC finder for details, then perform Recover from IPL or system failures. |
CAxx xxxx | These SRCs show the Status of an IPL. See the IPL SRC finder for details, then perform Recover from IPL or system failures. |
SRC | What it means |
---|---|
D1xx xxxx | Check for a specific D1xx SRC below. If you do not see
your SRC below, then the SRC is reporting IPL status. This is a normal indication
while the system main storage is being saved to disk. See the IPL SRC finder for details.
If the system is still not running correctly after 30 minutes, contact your hardware service provider. |
D1xx 3xxx | Service Processor Main Storage Dump status reference
code. This is a normal reference code showing the status of the system when
performing a main storage dump. You may suspect that the system is not
operating correctly when the rightmost characters do not change for 2 minutes.
Note: It takes approximately 1 minute to dump each 20MB of main storage.
|
D100 80xx | Operations Console error. See Troubleshoot system reference code (SRC) data for Operations Console. |
D2xx xxxx | These SRCs show the Status of an IPL. This is a normal indication while the panel functions and system code are powering down the system. See the IPL SRC finder for details, then perform Recover from IPL or system failures. |
D6xx xxxx | These SRCs show the Status of an IPL. This is a normal
indication while the system is being powered down. See the IPL SRC finder for details.
If the system does not start normally after 30 minutes, call your software service representative. When xxxx is changing, the system is doing a main storage dump. |
D9xx xxxx | These SRCs show the Status of an IPL. See the IPL SRC finder for details, then perform Recover from IPL or system failures. |
DAxx xxxx | These SRCs show the Status of an IPL. See the IPL SRC finder for details, then perform Recover from IPL or system failures. |
SRC | What it means |
---|---|
E600 xxxx | It may indicate a control panel failure. |
SRC | What it means |
---|---|
F000 xxxx | It may indicate a control panel failure. |