151 lines
7.6 KiB
HTML
151 lines
7.6 KiB
HTML
<?xml version="1.0" encoding="utf-8"?>
|
|
<!DOCTYPE html PUBLIC "-//W3C//DTD XHTML 1.0 Transitional//EN"
|
|
"http://www.w3.org/TR/xhtml1/DTD/xhtml1-transitional.dtd">
|
|
<html xmlns="http://www.w3.org/1999/xhtml" lang="en-US" xml:lang="en-us">
|
|
<head>
|
|
<meta http-equiv="Content-Type" content="text/html; charset=utf-8" />
|
|
<meta name="dc.language" scheme="rfc1766" content="en-us" />
|
|
<!-- All rights reserved. Licensed Materials Property of IBM -->
|
|
<!-- US Government Users Restricted Rights -->
|
|
<!-- Use, duplication or disclosure restricted by -->
|
|
<!-- GSA ADP Schedule Contract with IBM Corp. -->
|
|
<meta name="dc.date" scheme="iso8601" content="2005-09-06" />
|
|
<meta name="copyright" content="(C) Copyright IBM Corporation 1998, 2006" />
|
|
<meta name="security" content="public" />
|
|
<meta name="Robots" content="index,follow"/>
|
|
<meta http-equiv="PICS-Label" content='(PICS-1.1 "http://www.icra.org/ratingsv02.html" l gen true r (cz 1 lz 1 nz 1 oz 1 vz 1) "http://www.rsac.org/ratingsv01.html" l gen true r (n 0 s 0 v 0 l 0) "http://www.classify.org/safesurf/" l gen true r (SS~~000 1))' />
|
|
<title>Specify the SDLCLIN parameter for 3651 retail controllers</title>
|
|
<link rel="stylesheet" type="text/css" href="ibmidwb.css" />
|
|
<link rel="stylesheet" type="text/css" href="ic.css" />
|
|
</head>
|
|
<body>
|
|
<a id="Top_Of_Page" name="Top_Of_Page"></a><!-- Java sync-link -->
|
|
<script language = "Javascript" src = "../rzahg/synch.js" type="text/javascript"></script>
|
|
|
|
|
|
<a name="rzajt-cfg400to3651sdlc-rf"></a>
|
|
<h5 id="rzajt-cfg400to3651sdlc-rf">Specify the SDLCLIN parameter for 3651 retail controllers</h5>
|
|
<p>The following table describes how to coordinate values for parameters on
|
|
the iSeries™ CRTLINSDLC and CRTCTLRTL commands with bits that are specified
|
|
for the 3651 SDLCLIN parameter.</p>
|
|
<p>The SDLCLIN parameter is specified as a series of 8 bits, designated <tt class="xph">0</tt> through <tt class="xph">7</tt> (<tt class="xph">01234567</tt>). The default value for
|
|
the SDLCLIN parameter when used with an SDLC line is <tt class="xph">01100001</tt>,
|
|
or hex <tt class="xph">61</tt>.</p>
|
|
<p>The default value for each bit is underlined in the <span class="italic">Bit Value</span> column.</p>
|
|
<p>To configure the iSeries server to a 3651 controller, use the following
|
|
table.</p>
|
|
<a name="wq135"></a>
|
|
<table id="wq135" width="100%" summary="" border="1" frame="border" rules="all" class="singleborder">
|
|
<thead valign="bottom">
|
|
<tr>
|
|
<th id="wq136" width="20%" align="center" valign="bottom">SDLCLIN Bit</th>
|
|
<th id="wq137" width="12%" align="center" valign="bottom">Bit Value</th>
|
|
<th id="wq138" width="23%" align="center" valign="bottom">iSeries Parameter and Value</th>
|
|
<th id="wq139" width="43%" align="center" valign="bottom">Notes</th>
|
|
</tr>
|
|
</thead>
|
|
<tbody valign="top">
|
|
<tr>
|
|
<td rowspan="2" align="center" valign="top" headers="wq136">0</td>
|
|
<td align="center" valign="top" headers="wq137"><span class="underlined">0</span></td>
|
|
<td align="left" valign="top" headers="wq138">None</td>
|
|
<td rowspan="2" align="left" valign="top" headers="wq139">
|
|
<p>Data terminal ready. There
|
|
is no equivalent parameter for the iSeries system. Specify 0 to indicate that
|
|
the data terminal ready (DTR) signal is on when the controller is powered
|
|
on, or 1 to indicate that the DTR is off when the controller is powered on.</p>
|
|
<p>This bit should be set to 1 only if the configuration being defined
|
|
includes IBM® world trade data communications equipment (DCE) in a switched network.</p></td>
|
|
</tr>
|
|
<tr>
|
|
<td align="center" valign="top" headers="wq137">1</td>
|
|
<td align="left" valign="top" headers="wq138">None</td>
|
|
</tr>
|
|
<tr>
|
|
<td rowspan="2" align="center" valign="top" headers="wq136">1</td>
|
|
<td align="center" valign="top" headers="wq137">0</td>
|
|
<td align="left" valign="top" headers="wq138">NRZI(*NO)</td>
|
|
<td rowspan="2" align="left" valign="top" headers="wq139">Specify <tt class="xph">1</tt> if the
|
|
data communications equipment (DCE) provides the clocking or if NRZI data
|
|
encoding is used.</td>
|
|
</tr>
|
|
<tr>
|
|
<td align="center" valign="top" headers="wq137"><span class="underlined">1</span></td>
|
|
<td align="left" valign="top" headers="wq138">NRZI(*YES)</td>
|
|
</tr>
|
|
<tr>
|
|
<td rowspan="4" align="center" valign="top" headers="wq136">2 and 3</td>
|
|
<td align="center" valign="top" headers="wq137">00</td>
|
|
<td align="left" valign="top" headers="wq138">SWITCHED(*YES) CNN(*SWTPP)</td>
|
|
<td rowspan="4" align="left" valign="top" headers="wq139">
|
|
<p>Bit 2: Specify 1 if using
|
|
nonswitched communications, or 0 if using switched communications. If switched,
|
|
the SENDID parameter must also be specified.</p>
|
|
<p>Bit 3: Specify 1 if using
|
|
a multipoint communications protocol, or 0 if not. 01 is not a valid combination
|
|
for these bits.</p></td>
|
|
</tr>
|
|
<tr>
|
|
<td align="center" valign="top" headers="wq137">01</td>
|
|
<td align="left" valign="top" headers="wq138">Not valid</td>
|
|
</tr>
|
|
<tr>
|
|
<td align="center" valign="top" headers="wq137"><span class="underlined">10</span></td>
|
|
<td align="left" valign="top" headers="wq138">SWITCHED(*NO) and CNN(*NONSWTPP)</td>
|
|
</tr>
|
|
<tr>
|
|
<td align="center" valign="top" headers="wq137">11</td>
|
|
<td align="left" valign="top" headers="wq138">SWITCHED(*NO) and CNN(*MP)</td>
|
|
</tr>
|
|
<tr>
|
|
<td rowspan="2" align="center" valign="top" headers="wq136">4</td>
|
|
<td align="center" valign="top" headers="wq137"><span class="underlined">0</span></td>
|
|
<td align="left" valign="top" headers="wq138">None (See <span class="bold">Notes</span>)</td>
|
|
<td rowspan="2" align="left" valign="top" headers="wq139">Direct attachment. This bit
|
|
must be set to <tt class="xph">0</tt> for communications with the iSeries system.
|
|
There is no equivalent parameter for the iSeries system.</td>
|
|
</tr>
|
|
<tr>
|
|
<td align="center" valign="top" headers="wq137">1</td>
|
|
<td align="left" valign="top" headers="wq138">None</td>
|
|
</tr>
|
|
<tr>
|
|
<td rowspan="2" align="center" valign="top" headers="wq136">5</td>
|
|
<td align="center" valign="top" headers="wq137"><span class="underlined">0</span></td>
|
|
<td align="left" valign="top" headers="wq138">MODEMRATE(*FULL)</td>
|
|
<td rowspan="2" align="left" valign="top" headers="wq139">Modem data rate.</td>
|
|
</tr>
|
|
<tr>
|
|
<td align="center" valign="top" headers="wq137">1</td>
|
|
<td align="left" valign="top" headers="wq138">MODEMRATE(*HALF)</td>
|
|
</tr>
|
|
<tr>
|
|
<td rowspan="2" align="center" valign="top" headers="wq136">6</td>
|
|
<td align="center" valign="top" headers="wq137"><span class="underlined">0</span></td>
|
|
<td align="left" valign="top" headers="wq138">DUPLEX(*HALF)</td>
|
|
<td rowspan="2" align="left" valign="top" headers="wq139">Data carrier setting.</td>
|
|
</tr>
|
|
<tr>
|
|
<td align="center" valign="top" headers="wq137">1</td>
|
|
<td align="left" valign="top" headers="wq138">DUPLEX(*FULL)</td>
|
|
</tr>
|
|
<tr>
|
|
<td rowspan="2" align="center" valign="top" headers="wq136">7</td>
|
|
<td align="center" valign="top" headers="wq137">0</td>
|
|
<td align="left" valign="top" headers="wq138">None</td>
|
|
<td rowspan="2" align="left" valign="top" headers="wq139">Answer tone generation. There
|
|
is no equivalent parameter for the iSeries system. Specify <tt class="xph">0</tt> to indicate
|
|
that the modem generates the answer tone, or <tt class="xph">1</tt> to indicate that
|
|
the controller generates the answer tone.</td>
|
|
</tr>
|
|
<tr>
|
|
<td align="center" valign="top" headers="wq137"><span class="underlined">1</span></td>
|
|
<td align="left" valign="top" headers="wq138">None</td>
|
|
</tr>
|
|
</tbody>
|
|
</table>
|
|
<p>For information about SDLC, see <a href="rzajtrzajtsdlccon.htm#rzajtsdlc-con">Synchronous data link control network</a>.</p>
|
|