ibm-information-center/dist/eclipse/plugins/i5OS.ic.rzajt_5.4.0.1/rzajtrzajtcfg400to3651sdlcrf.htm

151 lines
7.6 KiB
HTML
Raw Normal View History

2024-04-02 14:02:31 +00:00
<?xml version="1.0" encoding="utf-8"?>
<!DOCTYPE html PUBLIC "-//W3C//DTD XHTML 1.0 Transitional//EN"
"http://www.w3.org/TR/xhtml1/DTD/xhtml1-transitional.dtd">
<html xmlns="http://www.w3.org/1999/xhtml" lang="en-US" xml:lang="en-us">
<head>
<meta http-equiv="Content-Type" content="text/html; charset=utf-8" />
<meta name="dc.language" scheme="rfc1766" content="en-us" />
<!-- All rights reserved. Licensed Materials Property of IBM -->
<!-- US Government Users Restricted Rights -->
<!-- Use, duplication or disclosure restricted by -->
<!-- GSA ADP Schedule Contract with IBM Corp. -->
<meta name="dc.date" scheme="iso8601" content="2005-09-06" />
<meta name="copyright" content="(C) Copyright IBM Corporation 1998, 2006" />
<meta name="security" content="public" />
<meta name="Robots" content="index,follow"/>
<meta http-equiv="PICS-Label" content='(PICS-1.1 "http://www.icra.org/ratingsv02.html" l gen true r (cz 1 lz 1 nz 1 oz 1 vz 1) "http://www.rsac.org/ratingsv01.html" l gen true r (n 0 s 0 v 0 l 0) "http://www.classify.org/safesurf/" l gen true r (SS~~000 1))' />
<title>Specify the SDLCLIN parameter for 3651 retail controllers</title>
<link rel="stylesheet" type="text/css" href="ibmidwb.css" />
<link rel="stylesheet" type="text/css" href="ic.css" />
</head>
<body>
<a id="Top_Of_Page" name="Top_Of_Page"></a><!-- Java sync-link -->
<script language = "Javascript" src = "../rzahg/synch.js" type="text/javascript"></script>
<a name="rzajt-cfg400to3651sdlc-rf"></a>
<h5 id="rzajt-cfg400to3651sdlc-rf">Specify the SDLCLIN parameter for 3651 retail controllers</h5>
<p>The following table describes how to coordinate values for parameters on
the iSeries&trade; CRTLINSDLC and CRTCTLRTL commands with bits that are specified
for the 3651 SDLCLIN parameter.</p>
<p>The SDLCLIN parameter is specified as a series of 8 bits, designated <tt class="xph">0</tt> through <tt class="xph">7</tt> (<tt class="xph">01234567</tt>). The default value for
the SDLCLIN parameter when used with an SDLC line is <tt class="xph">01100001</tt>,
or hex <tt class="xph">61</tt>.</p>
<p>The default value for each bit is underlined in the <span class="italic">Bit Value</span> column.</p>
<p>To configure the iSeries server to a 3651 controller, use the following
table.</p>
<a name="wq135"></a>
<table id="wq135" width="100%" summary="" border="1" frame="border" rules="all" class="singleborder">
<thead valign="bottom">
<tr>
<th id="wq136" width="20%" align="center" valign="bottom">SDLCLIN Bit</th>
<th id="wq137" width="12%" align="center" valign="bottom">Bit Value</th>
<th id="wq138" width="23%" align="center" valign="bottom">iSeries Parameter and Value</th>
<th id="wq139" width="43%" align="center" valign="bottom">Notes</th>
</tr>
</thead>
<tbody valign="top">
<tr>
<td rowspan="2" align="center" valign="top" headers="wq136">0</td>
<td align="center" valign="top" headers="wq137"><span class="underlined">0</span></td>
<td align="left" valign="top" headers="wq138">None</td>
<td rowspan="2" align="left" valign="top" headers="wq139">
<p>Data terminal ready. There
is no equivalent parameter for the iSeries system. Specify 0 to indicate that
the data terminal ready (DTR) signal is on when the controller is powered
on, or 1 to indicate that the DTR is off when the controller is powered on.</p>
<p>This bit should be set to 1 only if the configuration being defined
includes IBM&reg; world trade data communications equipment (DCE) in a switched network.</p></td>
</tr>
<tr>
<td align="center" valign="top" headers="wq137">1</td>
<td align="left" valign="top" headers="wq138">None</td>
</tr>
<tr>
<td rowspan="2" align="center" valign="top" headers="wq136">1</td>
<td align="center" valign="top" headers="wq137">0</td>
<td align="left" valign="top" headers="wq138">NRZI(*NO)</td>
<td rowspan="2" align="left" valign="top" headers="wq139">Specify <tt class="xph">1</tt> if the
data communications equipment (DCE) provides the clocking or if NRZI data
encoding is used.</td>
</tr>
<tr>
<td align="center" valign="top" headers="wq137"><span class="underlined">1</span></td>
<td align="left" valign="top" headers="wq138">NRZI(*YES)</td>
</tr>
<tr>
<td rowspan="4" align="center" valign="top" headers="wq136">2 and 3</td>
<td align="center" valign="top" headers="wq137">00</td>
<td align="left" valign="top" headers="wq138">SWITCHED(*YES) CNN(*SWTPP)</td>
<td rowspan="4" align="left" valign="top" headers="wq139">
<p>Bit 2: Specify 1 if using
nonswitched communications, or 0 if using switched communications. If switched,
the SENDID parameter must also be specified.</p>
<p>Bit 3: Specify 1 if using
a multipoint communications protocol, or 0 if not. 01 is not a valid combination
for these bits.</p></td>
</tr>
<tr>
<td align="center" valign="top" headers="wq137">01</td>
<td align="left" valign="top" headers="wq138">Not valid</td>
</tr>
<tr>
<td align="center" valign="top" headers="wq137"><span class="underlined">10</span></td>
<td align="left" valign="top" headers="wq138">SWITCHED(*NO) and CNN(*NONSWTPP)</td>
</tr>
<tr>
<td align="center" valign="top" headers="wq137">11</td>
<td align="left" valign="top" headers="wq138">SWITCHED(*NO) and CNN(*MP)</td>
</tr>
<tr>
<td rowspan="2" align="center" valign="top" headers="wq136">4</td>
<td align="center" valign="top" headers="wq137"><span class="underlined">0</span></td>
<td align="left" valign="top" headers="wq138">None (See <span class="bold">Notes</span>)</td>
<td rowspan="2" align="left" valign="top" headers="wq139">Direct attachment. This bit
must be set to <tt class="xph">0</tt> for communications with the iSeries system.
There is no equivalent parameter for the iSeries system.</td>
</tr>
<tr>
<td align="center" valign="top" headers="wq137">1</td>
<td align="left" valign="top" headers="wq138">None</td>
</tr>
<tr>
<td rowspan="2" align="center" valign="top" headers="wq136">5</td>
<td align="center" valign="top" headers="wq137"><span class="underlined">0</span></td>
<td align="left" valign="top" headers="wq138">MODEMRATE(*FULL)</td>
<td rowspan="2" align="left" valign="top" headers="wq139">Modem data rate.</td>
</tr>
<tr>
<td align="center" valign="top" headers="wq137">1</td>
<td align="left" valign="top" headers="wq138">MODEMRATE(*HALF)</td>
</tr>
<tr>
<td rowspan="2" align="center" valign="top" headers="wq136">6</td>
<td align="center" valign="top" headers="wq137"><span class="underlined">0</span></td>
<td align="left" valign="top" headers="wq138">DUPLEX(*HALF)</td>
<td rowspan="2" align="left" valign="top" headers="wq139">Data carrier setting.</td>
</tr>
<tr>
<td align="center" valign="top" headers="wq137">1</td>
<td align="left" valign="top" headers="wq138">DUPLEX(*FULL)</td>
</tr>
<tr>
<td rowspan="2" align="center" valign="top" headers="wq136">7</td>
<td align="center" valign="top" headers="wq137">0</td>
<td align="left" valign="top" headers="wq138">None</td>
<td rowspan="2" align="left" valign="top" headers="wq139">Answer tone generation. There
is no equivalent parameter for the iSeries system. Specify <tt class="xph">0</tt> to indicate
that the modem generates the answer tone, or <tt class="xph">1</tt> to indicate that
the controller generates the answer tone.</td>
</tr>
<tr>
<td align="center" valign="top" headers="wq137"><span class="underlined">1</span></td>
<td align="left" valign="top" headers="wq138">None</td>
</tr>
</tbody>
</table>
<p>For information about SDLC, see <a href="rzajtrzajtsdlccon.htm#rzajtsdlc-con">Synchronous data link control network</a>.</p>
<a id="Bot_Of_Page" name="Bot_Of_Page"></a>
</body>
</html>