Ensure that the currently installed server and logical partitions
are fully documented before the service representative arrives to perform
the expansion unit conversion. Make sure that these documents represent the
most recent configuration of the server and that no hardware changes have
been made since printing the documentation. If changes are made before the
service representative arrives, print the server and LPAR partition documentation
again.
Complete steps 1 through 5 for the primary
partition first; then repeat steps 1 through 3 and 5 for each secondary
partition. Step 4 should
be completed for the primary partition only.
- Print the disk configuration status from each partition
of the server.
- Print the parity set configuration and status from each
partition of the server. Be sure to mark each printout for the partition it
represents.
- Display, verify, and print the hardware resource information
for each partition of the server.
- On the primary partition, assign
all unassigned I/O resources to active partitions.
- Remove failed or nonreporting resources using the Hardware
Service Manager (HSM) on the partition.
- Repeat steps 1, 2, 3, and 5 above
for each secondary partition that is configured.
- Clear nonreporting logical partitioning resources on the primary
partition.
- Print the system configuration for logical partitions.
- Use the printouts from step 8 to determine if there are load-source resources in a bus
that will be changing bus numbers, for instance when a bus is converted or
recabled. For each partition with a load source drive in a converted or recabled
bus, count one drive if the partition has RAID or unprotected drives.
Count two drives if the partition has mirrored drives. Record the total
number of load source drives. Also record the serial number of the load source
disk (unit 1) for each converted or recabled bus. You will need this information
when you reconfigure bus or IOP ownership.
Example: P3 has a load source redundant array of independent disks (RAID)
of 1. P4 has a load source mirrored of 2. The value of P3 added to the value
of P4 equals 3. Record 3 as the total number of load source drives.
- Use the printouts from step 8 to determine the frame IDs and bus numbers associated
with all hardware that is changing. This information must be given to the
service representative and is required for the expansion unit conversion.
- For each secondary partition, record
the IPL System Action and then set the IPL System Action to HOLD as follows:
- From the primary partition, enter STRSST to start system service
tools (SST) and sign on to SST.
Note: To use system service tools,
you need a valid service tools user ID.
- From the SST main menu, select option 5 (Work with system partitions),
and press Enter. The Work with System Partitions display
appears.
- Use the Work with System Partitions display to select each secondary
partition. For each secondary partition, record the IPL System Action and
then set the IPL System Action to HOLD.
- Change the system value settings on both the primary partition
and each secondary partition.
- Use the appropriate procedure for your environment to turn off
the secondary partitions.
- The bus numbers change if buses are recabled. If you are running i5/OS™ V5R4 on all partitions,
use the partition configuration displays to move the buses that are being
converted and the buses that are being recabled into the primary partition.
For more information about moving buses, see the Perform dynamic movement
of resources topic.
- Use the appropriate procedure for your environment to turn off
the primary partition.
- Prepare the following documents for the service representative:
- LPAR Validation Tool output.
Note: This document should not change as
a result of the conversion.
- Disk configuration printouts for each partition.
Note: These documents
should not change as a result of the conversion.
- Parity set configuration printout for each partition.
Note: These documents
should not change as a result of the conversion.
- Description label locations printout for each partition.
Note: These documents
should not change as a result of the conversion.
- System configuration list printouts (from HSM) for each partition.
- Partition information printouts from the primary partition.