Jobs system values: Time-out interval for inactive jobs

Specifies the time-out interval for inactive jobs. (QINACTITV)

Time-out interval for inactive jobs, also known as QINACTITV, is a member of the jobs category of i5/OS™ system values. You can use this system value to specify the time interval that the system waits before taking the action that you specify for When job reaches time-out. To learn more, keep reading.

Quick reference
Location In iSeries™ Navigator, select your system, > Configuration and Service > System Values > Jobs > Interactive Jobs
Special authority All object (*ALLOBJ) and security administrator (*SECADM)
Default value Do not time-out
Changes take effect Immediately
Lockable No

What can I do with this system value?

Use the Time-out interval for inactive jobs and when a job reaches time-out options to specify how many minutes to give a job the chance to perform an activity before it is marked as inactive and the action to take when the time limit for an inactive job expires.

The time-out interval allows you to specify the inactive job time-out interval in minutes. When this time limit expires, the system takes action on inactive interactive jobs. This system value determines when to take action on an inactive job. Excluded are local jobs that are currently signed-on to a remote system. For example, a workstation is directly attached to System A, and System A has this system value set on. If you use pass-through or Telnet to sign on to System B, the time-out value set on System A does not affect this workstation.

The following are possible options:

Where can I get more information about this system value?

To learn more, go to the jobs system values overview topic. If you are looking for a specific system value or category of system values, try using the i5/OS system value finder.

Related concepts
System values: Jobs overview
Jobs system values: When a job reaches time-out
Jobs system values: Time-out interval for disconnected jobs
Related information