Install an Operations Console cable

How to install or remove the Operations Console cable

A cable is only required for a local console directly attached to the server or a local console directly attached to the server with remote access allowed configurations. You may need to install or remove the Operations Console cable, the remote control panel cable, or both, according to your server and your configuration

If you are changing the console device, the server's system value QAUTOCFG must be set to ON. Use one of the following to verify or set this system value on the server:
  • Use the WRKSYSVAL QAUTOCFG command.
  • During a manual IPL, in the IPL Options window, for Set major system options, select Y. Then for Enable automatic configuration, select Y.

Before making changes to the product, be sure to read the information in the Danger Notice.

Important: It is assumed the server is powered down. Do not power on the iSeries™ server until you are instructed to do so.
Note: You can also use the following instructions if you are removing one or more cables from your PC, server, or both.

If you have set up any personal computers that will be connected to the system unit:

  1. Power off all PCs.
  2. Unplug all PC power cords from the electrical outlets.

If you have not set up the PC that will be used as your system console:

  1. Place the PC not more than 6 meters (20 feet) from the system unit.
  2. Follow the instructions that came with the PC to set it up.
  3. Power off all PCs.
  4. Unplug all PC power cords from the electrical outlets.

You need to install the Operations Console cable if you want to use the console function (5250 emulation or command interface to iSeries server). If you want to use the console function and the remote control panel function, you need to install the Operations Console cable and the remote control panel cable.

This graphic is an overview of your system unit, console (PC) and Operations Console cable. This overview is intended to show you a general setup. The port location and part numbers could be different depending on the system and configuration that you have.


Operations Console cabling setup example

Cabling information is available with instructions and graphics to install your cables for each server model. Select your server from this list:

Related reference
Meet Operations Console cable requirements
Plan for your Operations Console install or upgrade
Remote control panel fails to start
Local console does not detect console cable