134 lines
7.9 KiB
HTML
134 lines
7.9 KiB
HTML
|
<?xml version="1.0" encoding="UTF-8"?>
|
||
|
<!DOCTYPE html
|
||
|
PUBLIC "-//W3C//DTD XHTML 1.0 Transitional//EN" "http://www.w3.org/TR/xhtml1/DTD/xhtml1-transitional.dtd">
|
||
|
<html lang="en-us" xml:lang="en-us">
|
||
|
<head>
|
||
|
<meta http-equiv="Content-Type" content="text/html; charset=utf-8" />
|
||
|
<meta name="security" content="public" />
|
||
|
<meta name="Robots" content="index,follow" />
|
||
|
<meta http-equiv="PICS-Label" content='(PICS-1.1 "http://www.icra.org/ratingsv02.html" l gen true r (cz 1 lz 1 nz 1 oz 1 vz 1) "http://www.rsac.org/ratingsv01.html" l gen true r (n 0 s 0 v 0 l 0) "http://www.classify.org/safesurf/" l gen true r (SS~~000 1))' />
|
||
|
<meta name="DC.Type" content="reference" />
|
||
|
<meta name="DC.Title" content="Install an Operations Console cable" />
|
||
|
<meta name="abstract" content="How to install or remove the Operations Console cable" />
|
||
|
<meta name="description" content="How to install or remove the Operations Console cable" />
|
||
|
<meta name="DC.Relation" scheme="URI" content="../rzam9/cable270instruct.htm" />
|
||
|
<meta name="DC.Relation" scheme="URI" content="../rzam9/cable52linstruct.htm" />
|
||
|
<meta name="DC.Relation" scheme="URI" content="../rzam9/cable820instruct.htm" />
|
||
|
<meta name="DC.Relation" scheme="URI" content="../rzam9/cable52minstruct.htm" />
|
||
|
<meta name="DC.Relation" scheme="URI" content="../rzam9/cable890instruct.htm" />
|
||
|
<meta name="DC.Relation" scheme="URI" content="rzajrprereqtasks.htm" />
|
||
|
<meta name="DC.Relation" scheme="URI" content="rzajrcable830.htm" />
|
||
|
<meta name="DC.Relation" scheme="URI" content="rzajrcables.htm" />
|
||
|
<meta name="DC.Relation" scheme="URI" content="rzajrplanupgrade.htm" />
|
||
|
<meta name="DC.Relation" scheme="URI" content="rzajrtroublercp.htm" />
|
||
|
<meta name="DC.Relation" scheme="URI" content="rzajrtroubledetectcable.htm" />
|
||
|
<meta name="copyright" content="(C) Copyright IBM Corporation 2000, 2006" />
|
||
|
<meta name="DC.Rights.Owner" content="(C) Copyright IBM Corporation 2000, 2006" />
|
||
|
<meta name="DC.Format" content="XHTML" />
|
||
|
<meta name="DC.Identifier" content="installcable" />
|
||
|
<meta name="DC.Language" content="en-us" />
|
||
|
<!-- All rights reserved. Licensed Materials Property of IBM -->
|
||
|
<!-- US Government Users Restricted Rights -->
|
||
|
<!-- Use, duplication or disclosure restricted by -->
|
||
|
<!-- GSA ADP Schedule Contract with IBM Corp. -->
|
||
|
<link rel="stylesheet" type="text/css" href="./ibmdita.css" />
|
||
|
<link rel="stylesheet" type="text/css" href="./ic.css" />
|
||
|
<title>Install an Operations Console cable</title>
|
||
|
</head>
|
||
|
<body id="installcable"><a name="installcable"><!-- --></a>
|
||
|
<!-- Java sync-link --><script language="Javascript" src="../rzahg/synch.js" type="text/javascript"></script>
|
||
|
<h1 class="topictitle1">Install an Operations Console cable</h1>
|
||
|
<div><p>How to install or remove the Operations Console cable</p>
|
||
|
<div class="section"><p>A cable is only required for a local console directly attached
|
||
|
to the server or a local console directly attached to the server with remote
|
||
|
access allowed configurations. You may need to install or remove the Operations
|
||
|
Console cable, the remote control panel cable, or both, according to your
|
||
|
server and your configuration</p>
|
||
|
<div class="p">If you are changing the console device,
|
||
|
the server's system value QAUTOCFG must be set to <span class="uicontrol">ON</span>.
|
||
|
Use one of the following to verify or set this system value on the server: <ul><li>Use the <span class="cmdname">WRKSYSVAL QAUTOCFG</span> command.</li>
|
||
|
<li>During a manual IPL, in the IPL Options window, for <span class="uicontrol">Set major
|
||
|
system options</span>, select <span class="uicontrol">Y</span>. Then for <span class="uicontrol">Enable
|
||
|
automatic configuration</span>, select <span class="uicontrol">Y</span>.</li>
|
||
|
</ul>
|
||
|
</div>
|
||
|
</div>
|
||
|
<div class="section"><p>Before making changes to the product, be sure to read the information
|
||
|
in the <a href="../rzahg/danger.htm">Danger
|
||
|
Notice</a>.</p>
|
||
|
</div>
|
||
|
<div class="section"><div class="important"><span class="importanttitle">Important:</span> It is assumed the server is powered down.
|
||
|
Do not power on the iSeries™ server until you are instructed to do so.</div>
|
||
|
</div>
|
||
|
<div class="section"><div class="p"> <div class="note"><span class="notetitle">Note:</span> You can also use the following instructions if you are
|
||
|
removing one or more cables from your PC, server, or both.</div>
|
||
|
</div>
|
||
|
</div>
|
||
|
<div class="section"><p>If you <strong><em>have set up</em></strong> any personal computers that will
|
||
|
be connected to the system unit:</p>
|
||
|
</div>
|
||
|
<div class="section"> <ol><li>Power off all PCs.</li>
|
||
|
<li>Unplug all PC power cords from the electrical outlets.</li>
|
||
|
</ol>
|
||
|
</div>
|
||
|
<div class="section"><p>If you <strong><em>have not set up</em></strong> the PC that will be used
|
||
|
as your system console:</p>
|
||
|
</div>
|
||
|
<div class="section"> <ol><li>Place the PC not more than 6 meters (20 feet) from the system unit.</li>
|
||
|
<li>Follow the instructions that came with the PC to set it up.</li>
|
||
|
<li>Power off all PCs.</li>
|
||
|
<li>Unplug all PC power cords from the electrical outlets.</li>
|
||
|
</ol>
|
||
|
</div>
|
||
|
<div class="section"><p>You need to install the Operations Console cable if you want to
|
||
|
use the console function (5250 emulation or command interface to iSeries server).
|
||
|
If you want to use the console function and the remote control panel function,
|
||
|
you need to install the Operations Console cable and the remote control panel
|
||
|
cable.</p>
|
||
|
</div>
|
||
|
<div class="section"><p>This graphic is an overview of your system unit, console (PC)
|
||
|
and Operations Console cable. This overview is intended to show you a general
|
||
|
setup. The port location and part numbers could be different depending on
|
||
|
the system and configuration that you have.</p>
|
||
|
</div>
|
||
|
<div class="section"><p><br /><img src="rzajr507.gif" alt="Operations Console cabling setup example" /><br /></p>
|
||
|
</div>
|
||
|
<div class="section"><p>Cabling information is available with instructions and graphics
|
||
|
to install your cables for each server model. Select your server from this
|
||
|
list:</p>
|
||
|
</div>
|
||
|
</div>
|
||
|
<div>
|
||
|
<ul class="ullinks">
|
||
|
<li class="ulchildlink"><strong><a href="../rzam9/cable270instruct.htm">Model
|
||
|
270</a></strong><br />
|
||
|
</li>
|
||
|
<li class="ulchildlink"><strong><a href="../rzam9/cable52linstruct.htm">Model 800, 810</a></strong><br />
|
||
|
</li>
|
||
|
<li class="ulchildlink"><strong><a href="../rzam9/cable820instruct.htm">Model
|
||
|
820</a></strong><br />
|
||
|
</li>
|
||
|
<li class="ulchildlink"><strong><a href="../rzam9/cable52minstruct.htm">Model
|
||
|
825</a></strong><br />
|
||
|
</li>
|
||
|
<li class="ulchildlink"><strong><a href="../rzam9/cable890instruct.htm">Model
|
||
|
870, 890</a></strong><br />
|
||
|
<div class="note"><span class="notetitle">Note:</span> The Operations Console cable should be installed by your service
|
||
|
provider for these servers.</div>
|
||
|
</li>
|
||
|
<li class="ulchildlink"><strong><a href="rzajrcable830.htm">Cable a Model 830 or a Model 840 Operations Console</a></strong><br />
|
||
|
</li>
|
||
|
</ul>
|
||
|
|
||
|
<div class="familylinks">
|
||
|
<div class="parentlink"><strong>Parent topic:</strong> <a href="rzajrprereqtasks.htm" title="Complete each prerequisite task needed for your configuration and operating system. This reference section lists all of the required tasks that you should complete before configuring Operations Console.">Complete required prerequisite tasks</a></div>
|
||
|
</div>
|
||
|
<div class="relref"><strong>Related reference</strong><br />
|
||
|
<div><a href="rzajrcables.htm" title="You need to meet the following cable requirements for supported servers, cables and card locations.">Meet Operations Console cable requirements</a></div>
|
||
|
<div><a href="rzajrplanupgrade.htm" title="In order to plan for your Operations Console install or upgrade, you need to know this information.">Plan for your Operations Console install or upgrade</a></div>
|
||
|
<div><a href="rzajrtroublercp.htm" title="If your remote control panel fails to start, verify the following:">Remote control panel fails to start</a></div>
|
||
|
<div><a href="rzajrtroubledetectcable.htm" title="These are solutions to problems that occur when the local console does not detect the presence of the Operations Console cable.">Local console does not detect console cable</a></div>
|
||
|
</div>
|
||
|
</div>
|
||
|
</body>
|
||
|
</html>
|