<?xml version="1.0" encoding="UTF-8"?>
|
|
<!DOCTYPE html
|
|
PUBLIC "-//W3C//DTD XHTML 1.0 Transitional//EN" "http://www.w3.org/TR/xhtml1/DTD/xhtml1-transitional.dtd">
|
|
<html lang="en-us" xml:lang="en-us">
|
|
<head>
|
|
<meta http-equiv="Content-Type" content="text/html; charset=utf-8" />
|
|
<meta name="security" content="public" />
|
|
<meta name="Robots" content="index,follow" />
|
|
<meta http-equiv="PICS-Label" content='(PICS-1.1 "http://www.icra.org/ratingsv02.html" l gen true r (cz 1 lz 1 nz 1 oz 1 vz 1) "http://www.rsac.org/ratingsv01.html" l gen true r (n 0 s 0 v 0 l 0) "http://www.classify.org/safesurf/" l gen true r (SS~~000 1))' />
|
|
<meta name="DC.Type" content="concept" />
|
|
<meta name="DC.Title" content="Virtual control panel" />
|
|
<meta name="abstract" content="The virtual control panel is an alternative to the remote control panel for parallel cable. Like the remote control panel, the virtual control panel is a way to use control panel functions through a PC." />
|
|
<meta name="description" content="The virtual control panel is an alternative to the remote control panel for parallel cable. Like the remote control panel, the virtual control panel is a way to use control panel functions through a PC." />
|
|
<meta name="DC.Relation" scheme="URI" content="rzatmcpcomparison.htm" />
|
|
<meta name="DC.Relation" scheme="URI" content="../rzamh/rzamhsrvtoolidchgprivsst.htm" />
|
|
<meta name="DC.Relation" scheme="URI" content="http://www.ibm.com/eserver/iseries/access/console" />
|
|
<meta name="DC.Relation" scheme="URI" content="rzatmusingcontrolpanel.htm" />
|
|
<meta name="DC.Relation" scheme="URI" content="rzatmcpdetails.htm" />
|
|
<meta name="copyright" content="(C) Copyright IBM Corporation 2000, 2006" />
|
|
<meta name="DC.Rights.Owner" content="(C) Copyright IBM Corporation 2000, 2006" />
|
|
<meta name="DC.Format" content="XHTML" />
|
|
<meta name="DC.Identifier" content="rzatmvirtualcp" />
|
|
<meta name="DC.Language" content="en-us" />
|
|
<!-- All rights reserved. Licensed Materials Property of IBM -->
|
|
<!-- US Government Users Restricted Rights -->
|
|
<!-- Use, duplication or disclosure restricted by -->
|
|
<!-- GSA ADP Schedule Contract with IBM Corp. -->
|
|
<link rel="stylesheet" type="text/css" href="./ibmdita.css" />
|
|
<link rel="stylesheet" type="text/css" href="./ic.css" />
|
|
<title>Virtual control panel</title>
|
|
</head>
|
|
<body id="rzatmvirtualcp"><a name="rzatmvirtualcp"><!-- --></a>
|
|
<!-- Java sync-link --><script language="Javascript" src="../rzahg/synch.js" type="text/javascript"></script>
|
|
<h1 class="topictitle1">Virtual control panel</h1>
|
|
<div><p>The virtual control panel is an alternative to the remote control
|
|
panel for parallel cable. Like the remote control panel, the virtual control
|
|
panel is a way to use control panel functions through a PC.</p>
|
|
<p><img src="./delta.gif" alt="Start of change" />The graphical user interface for the virtual control panel is
|
|
identical to the remote control panel. Also, the virtual control panel can
|
|
perform most of the same functions as the remote control panel. If your server
|
|
uses a keystick, the <span class="uicontrol">mode</span> button works with the same
|
|
functions as the physical control panel, depending on whether the keystick
|
|
is inserted.<img src="./deltaend.gif" alt="End of change" /></p>
|
|
<p>The biggest functional difference between the remote control panel and
|
|
the virtual control panel is that the virtual control panel cannot power on
|
|
the server. As an alternative, if you need to power on the system at a later
|
|
time, you can use the IPL scheduling function in Operational Assistant, by
|
|
pressing the <span class="uicontrol">Attention</span> key. You can also use the GO
|
|
POWER command and select option 2 (Change power on and off schedule).</p>
|
|
<div class="section"><h4 class="sectiontitle">Considerations for the virtual control panel</h4><p>If
|
|
you use the virtual control panel, you should be aware of the following considerations:</p>
|
|
<ul><li>The virtual control panel must have a direct connection to the server
|
|
from Operations Console using the serial console cable.</li>
|
|
<li>The virtual control panel is only available while the Operations Console
|
|
is connected.</li>
|
|
<li>You cannot use the virtual control panel remotely through a dial up connection.</li>
|
|
<li>There are prerequisites to installing the virtual control panel such as
|
|
PTFs for the server and service packs for the client.</li>
|
|
<li>If the PC has a parallel cable connection for a remote control panel,
|
|
you must remove it before you can install and use your virtual control panel.</li>
|
|
<li>A unique service tools device profile must exist for each virtual control
|
|
panel connection.</li>
|
|
<li>You cannot use an existing network name.</li>
|
|
<li>More than one virtual control panel and remote control panel can be active
|
|
at the same time.</li>
|
|
<li><img src="./delta.gif" alt="Start of change" />The service tools user ID used to authenticate
|
|
the connection must have the Partition remote panel key privilege in order
|
|
to use the mode function provided by the virtual control panel. To verify
|
|
that your service tools user ID has this privilege, see Change the functional
|
|
privileges for a service tools user ID using SST.<img src="./deltaend.gif" alt="End of change" /></li>
|
|
</ul>
|
|
</div>
|
|
<div class="section"><h4 class="sectiontitle">How to choose between the virtual control panel and remote
|
|
control panel</h4><p>The following table shows which server models are
|
|
recommended for the virtual control panel and which models are recommended
|
|
for the remote control panel.</p>
|
|
|
|
<div class="tablenoborder"><table cellpadding="4" cellspacing="0" summary="" frame="border" border="1" rules="all"><thead align="left"><tr><th valign="top" id="d0e60">Virtual control panel</th>
|
|
<th valign="top" id="d0e62">Remote control panel</th>
|
|
</tr>
|
|
</thead>
|
|
<tbody><tr><td valign="top" headers="d0e60 "><p>270 <br />
|
|
800 <br />
|
|
810 <br />
|
|
820 <br />
|
|
825 <br />
|
|
830 <br />
|
|
840 <br />
|
|
870 <br />
|
|
890</p>
|
|
</td>
|
|
<td valign="top" headers="d0e62 "><p>170 <br />
|
|
250 <br />
|
|
6xx <br />
|
|
7xx <br />
|
|
Sxx </p>
|
|
</td>
|
|
</tr>
|
|
</tbody>
|
|
</table>
|
|
</div>
|
|
<p>For information such as prerequisites, setup instructions, and
|
|
configuration instructions for the virtual control panel, see the iSeries™ Access
|
|
Web site.</p>
|
|
<p><img src="./delta.gif" alt="Start of change" />For information about using the virtual control
|
|
panel see Access control panel functions. See Control panel buttons, lights,
|
|
and indicators for a description of the interface for the virtual control
|
|
panel.<img src="./deltaend.gif" alt="End of change" /></p>
|
|
</div>
|
|
</div>
|
|
<div>
|
|
<div class="familylinks">
|
|
<div class="parentlink"><strong>Parent topic:</strong> <a href="rzatmcpcomparison.htm" title="This information compares and contrasts the virtual control panel, remote control panel, and physical control panel.">Types of control panels</a></div>
|
|
</div>
|
|
<div class="relconcepts"><strong>Related concepts</strong><br />
|
|
<div><a href="rzatmcpdetails.htm" title="This information describes the interface for each type of control panel.">Control panel buttons, lights, and indicators</a></div>
|
|
</div>
|
|
<div class="reltasks"><strong>Related tasks</strong><br />
|
|
<div><a href="../rzamh/rzamhsrvtoolidchgprivsst.htm">Change the functional privileges for a service tools user ID using SST</a></div>
|
|
<div><a href="rzatmusingcontrolpanel.htm" title="This information provides steps that explain how to access the control panel functions.">Access control panel functions</a></div>
|
|
</div>
|
|
<div class="relinfo"><strong>Related information</strong><br />
|
|
<div><a href="http://www.ibm.com/eserver/iseries/access/console" target="_blank">iSeries Operations Console</a></div>
|
|
</div>
|
|
</div>
|
|
</body>
|
|
</html> |