<meta name="DC.Title" content="Minimized entry-specific data for journal entries" />
|
||
<meta name="abstract" content="On the Create Journal (CRTJRN) and Change Journal (CHGJRN) commands, you can specify to allow for the deposit of minimized journal entries. This will decrease the size of your journal entries." />
|
||
<meta name="description" content="On the Create Journal (CRTJRN) and Change Journal (CHGJRN) commands, you can specify to allow for the deposit of minimized journal entries. This will decrease the size of your journal entries." />
|
||
<meta name="DC.Relation" scheme="URI" content="rzakiplnjrnsu.htm" />
|
||
<meta name="DC.Relation" scheme="URI" content="rzakiexplfldbdy.htm" />
|
||
<meta name="DC.Relation" scheme="URI" content="rzakiguivsgs.htm" />
|
||
<meta name="DC.Relation" scheme="URI" content="rzakiestimatercv.htm" />
|
||
<meta name="DC.Relation" scheme="URI" content="../cl/crtjrn.htm" />
|
||
<meta name="DC.Relation" scheme="URI" content="../cl/chgjrn.htm" />
|
||
<meta name="DC.Relation" scheme="URI" content="rzakifinder.htm" />
|
||
<meta name="DC.Relation" scheme="URI" content="rzakiwrkminendta.htm" />
|
||
<meta name="copyright" content="(C) Copyright IBM Corporation 2004, 2006" />
|
||
<meta name="DC.Rights.Owner" content="(C) Copyright IBM Corporation 2004, 2006" />
|
||
<meta name="DC.Format" content="XHTML" />
|
||
<meta name="DC.Identifier" content="rzakiminendta" />
|
||
<meta name="DC.Language" content="en-us" />
|
||
<!-- All rights reserved. Licensed Materials Property of IBM -->
|
||
<!-- US Government Users Restricted Rights -->
|
||
<!-- Use, duplication or disclosure restricted by -->
|
||
<!-- GSA ADP Schedule Contract with IBM Corp. -->
|
||
<link rel="stylesheet" type="text/css" href="./ibmdita.css" />
|
||
<link rel="stylesheet" type="text/css" href="./ic.css" />
|
||
<title>Minimized entry-specific data for journal entries</title>
|
||
</head>
|
||
<body id="rzakiminendta"><a name="rzakiminendta"><!-- --></a>
|
||
<!-- Java sync-link --><script language="Javascript" src="../rzahg/synch.js" type="text/javascript"></script>
|
||
<h1 class="topictitle1">Minimized entry-specific data for journal entries</h1>
|
||
<div><p>On the Create Journal (CRTJRN) and Change Journal (CHGJRN) commands,
|
||
you can specify to allow for the deposit of minimized journal entries. This
|
||
will decrease the size of your journal entries.</p>
|
||
<p>When you specify the Minimized Entry Specific Data (MINENTDTA) parameter
|
||
for an object type, the entry-specific data for the entries of those object
|
||
types can be minimized. You can minimize journal entries for database physical
|
||
files and data areas.</p>
|
||
<p>The system only minimizes entries if the minimized entry is smaller in
|
||
size than a complete journal entry deposit. Therefore, even if you specify
|
||
this option, not all entries that are deposited will be minimized. The Display
|
||
Journal (DSPJRN) command, Receiver Journal Entry (RCVJRNE) command, Retrieve
|
||
Journal Entry (RTVJRNE) command, and QjoRetrieveJournalEntries API return
|
||
data that indicates whether the entry is actually minimized.</p>
|
||
<p><img src="./delta.gif" alt="Start of change" />The *FILE, *DTAARA, and *FLDBDY values are allowed
|
||
on the MINENTDTA parameter for the CRTJRN and CHGJRN commands and indicate
|
||
the following: <img src="./deltaend.gif" alt="End of change" /></p>
|
||
<dl><dt class="dlterm"><img src="./delta.gif" alt="Start of change" />*FILE <img src="./deltaend.gif" alt="End of change" /></dt>
|
||
<dd>Journaled files may have journal entries deposited with minimized entry
|
||
specific data. The minimizing will not occur on field boundaries, and the
|
||
entry specific data may not be viewable and may not be used for auditing purposes.
|
||
This value cannot be specified if *FLDBDY is specified.</dd>
|
||
</dl>
|
||
<dl><dt class="dlterm"><img src="./delta.gif" alt="Start of change" />*FLDBDY<img src="./deltaend.gif" alt="End of change" /></dt>
|
||
<dd>Journaled files may have journal entries deposited with minimized entry
|
||
specific data. The minimizing will occur on field boundaries, and the entry
|
||
specific data will be viewable and may be used for auditing purposes.<img src="./delta.gif" alt="Start of change" /><ul><li>The DSPJRN command always displays the entries which have been minimized
|
||
on field boundaries with formatting.</li>
|
||
<li><img src="./delta.gif" alt="Start of change" />The *FILE value is not available in releases prior to V5R4.<img src="./deltaend.gif" alt="End of change" /></li>
|
||
</ul><img src="./deltaend.gif" alt="End of change" />
|
||
</dd>
|
||
</dl>
|
||
<dl><dt class="dlterm"><img src="./delta.gif" alt="Start of change" />*DTAARA <img src="./deltaend.gif" alt="End of change" /></dt>
|
||
<dd><img src="./delta.gif" alt="Start of change" />Journaled data areas may have journal entries deposited with
|
||
minimized entry specific data.<img src="./deltaend.gif" alt="End of change" /></dd>
|
||
</dl>
|
||
<div class="note"><span class="notetitle">Note:</span> <img src="./delta.gif" alt="Start of change" />You cannot save or restore a journal receiver with minimized
|
||
journal entries to any release prior to V5R1M0, nor can they be replicated
|
||
to any remote journal on a system at a release prior to V5R1M0.<img src="./deltaend.gif" alt="End of change" /></div>
|
||
<p><img src="./delta.gif" alt="Start of change" />An optional parameter, Format minimized data (FMTMINDTA), is
|
||
available on the Retrieve Journal Entries (RTVJRNE) command, the Receive Journal
|
||
Entries (RCVJRNE) command, and the Retrieve Journal Entries (QjoRetrieveJournalEntries)
|
||
API. This parameter allows you to specify whether entry specific data which
|
||
has been minimized on field boundaries will be returned in a readable format,
|
||
which allows you to determine what changes have been made. The possible values
|
||
for the FMTMINDTA parameter are *NO or *YES, with the default being *NO. By
|
||
default, the methods used by these commands provide the data in their raw
|
||
format. The RTVJRNE command will indicate whether or not *FLDBDY has been
|
||
specified for Minimized entry specific data with a value of ‘2’ in the already
|
||
existing “MINIMIZED ENTRY DATA” field for the appropriate entry formats. *FILE
|
||
and *DTAARA will appear as '1' in their fields.<img src="./deltaend.gif" alt="End of change" /></p>
|
||
<p><img src="./delta.gif" alt="Start of change" />Using the Display Journal (DSPJRN) command, entries are viewable
|
||
to the screen, an outfile, or printed output. The DSPJRN command will also
|
||
indicate whether or not the *FLDBDY value has been specified for Minimized
|
||
entry specific data on the “Display Journal Entry” panel and will indicate
|
||
a value of ‘2’ in the “Minimized entry specific data” field of the *OUTFILE
|
||
and in the “Min” field of the printed output. *FILE and *DTAARA will appear
|
||
as '1' in their fields.<img src="./deltaend.gif" alt="End of change" /></p>
|
||
<p>See the Journal code finder link below to see which entries are eligible
|
||
for minimization. See the Considerations for entries which contain minimized
|
||
entry-specific data link for more information and considerations when using
|
||
these entries.</p>
|
||
<p><img src="./delta.gif" alt="Start of change" />SUBJECT TO ANY STATUTORY WARRANTIES WHICH CANNOT BE EXCLUDED,
|
||
IBM, ITS PROGRAM DEVELOPERS AND SUPPLIERS MAKE NO WARRANTIES OR CONDITIONS
|
||
EITHER EXPRESS OR IMPLIED, INCLUDING BUT NOT LIMITED TO, THE IMPLIED WARRANTIES
|
||
OR CONDITIONS OF MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE, AND NON-INFRINGEMENT,
|
||
REGARDING THE PROGRAM OR TECHNICAL SUPPORT, IF ANY. <img src="./deltaend.gif" alt="End of change" /></p>
|
||
<p><img src="./delta.gif" alt="Start of change" />UNDER NO CIRCUMSTANCES IS IBM, ITS PROGRAM DEVELOPERS OR SUPPLIERS
|
||
LIABLE FOR ANY OF THE FOLLOWING, EVEN IF INFORMED OF THEIR POSSIBILITY: <img src="./deltaend.gif" alt="End of change" /></p>
|
||
<img src="./delta.gif" alt="Start of change" /><ol><li>LOSS OF, OR DAMAGE TO, DATA;</li>
|
||
<li>DIRECT, SPECIAL, INCIDENTAL, OR INDIRECT DAMAGES, OR FOR ANY ECONOMIC
|
||
CONSEQUENTIAL DAMAGES; OR </li>
|
||
<li>LOST PROFITS, BUSINESS, REVENUE, GOODWILL, OR ANTICIPATED SAVINGS.</li>
|
||
</ol><img src="./deltaend.gif" alt="End of change" />
|
||
<p><img src="./delta.gif" alt="Start of change" />SOME JURISDICTIONS DO NOT ALLOW THE EXCLUSION OR LIMITATION
|
||
OF DIRECT, INCIDENTAL, OR CONSEQUENTIAL DAMAGES, SO SOME OR ALL OF THE ABOVE
|
||
LIMITATIONS OR EXCLUSIONS MAY NOT APPLY TO YOU.<img src="./deltaend.gif" alt="End of change" /></p>
|
||
</div>
|
||
<div>
|
||
<ul class="ullinks">
|
||
<li class="ulchildlink"><img src="./delta.gif" alt="Start of change" /><strong><a href="rzakiexplfldbdy.htm">Example: MINENTDTA (*FLDBDY)</a></strong><img src="./deltaend.gif" alt="End of change" /><br />
|
||
The following SQL script provides an example of the of the *FLDBDY value used with the Minimized entry specific data (MINENTDTA) parameter for the CRTJRN and CHGJRN commands.</li>
|
||
</ul>
|
||
|
||
<div class="familylinks">
|
||
<div class="parentlink"><strong>Parent topic:</strong> <a href="rzakiplnjrnsu.htm" title="The following topics provide information to plan configuration for journals. They provide information about each option that you can select for journal.">Plan setup for journals</a></div>
|
||
</div>
|
||
<div class="relconcepts"><strong>Related concepts</strong><br />
|
||
<div><a href="rzakiguivsgs.htm" title="There are two environments that you can use for journal management: iSeries Navigator and the character-based interface. iSeries Navigator provides a graphical interface for journaling that is easy to use and does not require the use of control language (CL) commands. The character-based interface requires the use of CL commands or APIs, but has more functionality than iSeries Navigator.">iSeries Navigator versus the character-based interface for journaling objects</a></div>
|
||
<div><a href="rzakiwrkminendta.htm" title="Reduce the size of journal receivers by specifying minimized entry-specific data on the Create Journal (CRTJRN) and Change Journal (CHGJRN) commands.">Considerations for entries which contain minimized entry-specific data</a></div>
|
||
</div>
|
||
<div class="reltasks"><strong>Related tasks</strong><br />
|
||
<div><a href="rzakiestimatercv.htm" title="You can use the methods below to estimate the effect a journal receiver will have on auxiliary storage.">Methods to estimate the size of a journal receiver</a></div>
|
||
</div>
|
||
<div class="relref"><strong>Related reference</strong><br />
|
||
<div><a href="../cl/crtjrn.htm">Create Journal (CRTJRN) command</a></div>
|
||
<div><a href="../cl/chgjrn.htm">Change Journal (CHGJRN) command</a></div>
|
||
</div>
|
||
<div class="relinfo"><strong>Related information</strong><br />
|
||
<div><a href="rzakifinder.htm">Journal code finder</a></div>
|
||
</div>
|
||
</div>
|
||
</body>
|
||
</html> |