ibm-information-center/dist/eclipse/plugins/i5OS.ic.rzajt_5.4.0.1/rzajtrzajtcfg400to4684rf.htm

146 lines
8.1 KiB
HTML

<?xml version="1.0" encoding="utf-8"?>
<!DOCTYPE html PUBLIC "-//W3C//DTD XHTML 1.0 Transitional//EN"
"http://www.w3.org/TR/xhtml1/DTD/xhtml1-transitional.dtd">
<html xmlns="http://www.w3.org/1999/xhtml" lang="en-US" xml:lang="en-us">
<head>
<meta http-equiv="Content-Type" content="text/html; charset=utf-8" />
<meta name="dc.language" scheme="rfc1766" content="en-us" />
<!-- All rights reserved. Licensed Materials Property of IBM -->
<!-- US Government Users Restricted Rights -->
<!-- Use, duplication or disclosure restricted by -->
<!-- GSA ADP Schedule Contract with IBM Corp. -->
<meta name="dc.date" scheme="iso8601" content="2005-09-06" />
<meta name="copyright" content="(C) Copyright IBM Corporation 1998, 2006" />
<meta name="security" content="public" />
<meta name="Robots" content="index,follow"/>
<meta http-equiv="PICS-Label" content='(PICS-1.1 "http://www.icra.org/ratingsv02.html" l gen true r (cz 1 lz 1 nz 1 oz 1 vz 1) "http://www.rsac.org/ratingsv01.html" l gen true r (n 0 s 0 v 0 l 0) "http://www.classify.org/safesurf/" l gen true r (SS~~000 1))' />
<title>Match iSeries system parameters for 4684 retail controllers</title>
<link rel="stylesheet" type="text/css" href="ibmidwb.css" />
<link rel="stylesheet" type="text/css" href="ic.css" />
</head>
<body>
<a id="Top_Of_Page" name="Top_Of_Page"></a><!-- Java sync-link -->
<script language = "Javascript" src = "../rzahg/synch.js" type="text/javascript"></script>
<a name="rzajt-cfg400to4684-rf"></a>
<h4 id="rzajt-cfg400to4684-rf">Match iSeries system parameters for 4684 retail controllers</h4>
<p>You must coordinate parameter values with the iSeries&trade; server and the 4684 retail controller
when running IBM&reg; Retail Industry Programming Support Services (RIPSS). The following
table lists those parameters.</p>
<p>iSeries parameters are listed in alphabetical order; the commands on
which the parameters are specified are included in the rightmost column of
the table.</p>
<p>For more information about configuring for RIPSS on the 4684, see the <cite>IBM Retail Industry Programming Support Services:
Planning and Installation Guide</cite>,
SC33-0650.</p>
<p>To configure the iSeries server to a 4684 controller:</p>
<ul>
<li>See <a href="rzajtrzajtcfg400to4690exre.htm#rzajt-cfg400to4690ex-re">Example: iSeries server connection to a 4690 retail controller</a> for an example of an iSeries server connecting
to a 4690 retail controller.</li>
<li>Use the following table to connect to a 4690 retail controller.</li></ul>
<a name="wq159"></a>
<table id="wq159" width="100%" summary="" border="1" frame="border" rules="all" class="singleborder">
<thead valign="bottom">
<tr>
<th id="wq160" width="17%" align="center" valign="bottom">iSeries Prompt</th>
<th id="wq161" width="16%" align="center" valign="bottom">iSeries Parameter</th>
<th id="wq162" width="20%" align="center" valign="bottom">RIPSS Configuration Display</th>
<th id="wq163" width="45%" align="center" valign="bottom">RIPSS Prompt</th>
</tr>
</thead>
<tbody valign="top">
<tr>
<td align="left" valign="top" headers="wq160">LAN remote adapter address</td>
<td align="left" valign="top" headers="wq161">ADPTADR</td>
<td align="left" valign="top" headers="wq162">TRDLC Server Data</td>
<td align="left" valign="top" headers="wq163"><span class="italic">Local node (Hex)</span>
<p>For Token-Ring connections, the values specified for the RIPSS configuration
and for the iSeries CRTCTLRTL command must match.</p></td>
</tr>
<tr>
<td align="left" valign="top" headers="wq160">Local adapter address</td>
<td align="left" valign="top" headers="wq161">ADPTADR</td>
<td align="left" valign="top" headers="wq162">TRDLC Server Data</td>
<td align="left" valign="top" headers="wq163"><span class="italic">Remote node (Hex)</span>
<p>For Token-Ring connections, the values specified for the RIPSS configuration
and for the iSeries CRTLINTRN command must match.</p></td>
</tr>
<tr>
<td align="left" valign="top" headers="wq160">Destination service access point</td>
<td align="left" valign="top" headers="wq161">DSAP</td>
<td align="left" valign="top" headers="wq162">TRDLC Server Data</td>
<td align="left" valign="top" headers="wq163"><span class="italic">Local SAP (Hex)</span>
<p>For Token-Ring connections, the values specified for the RIPSS configuration
and for the iSeries CRTCTLRTL command must match.</p></td>
</tr>
<tr>
<td align="left" valign="top" headers="wq160">Duplex</td>
<td align="left" valign="top" headers="wq161">DUPLEX</td>
<td align="left" valign="top" headers="wq162">SDLC Server Data</td>
<td align="left" valign="top" headers="wq163"><span class="italic">4-wire constant RTS?</span>
<p>For SDLC connections, the values specified for RIPSS and iSeries configurations
must match: </p>
<ul>
<li>If the RIPSS response is <tt class="xph">N</tt>, DUPLEX(*HALF) must be specified
for the CRTLINSDLC command.</li>
<li>If the RIPSS response is <tt class="xph">Y</tt>, DUPLEX(YES) must be specified for
the CRTLINSDLC command.</li></ul></td>
</tr>
<tr>
<td align="left" valign="top" headers="wq160">Exchange identifier</td>
<td align="left" valign="top" headers="wq161">EXCHID</td>
<td align="left" valign="top" headers="wq162">SDLC Server Data</td>
<td align="left" valign="top" headers="wq163"><span class="italic">Block number (hex)</span> and <span class="italic">XID (hex)</span>
<p>For SDLC connections, the values specified
for the RIPSS configuration must match the value specified in the EXCHID parameter
of the CRTCTLRTL command. The EXCHID parameter must be specified as: <tt class="xph">xxxyyyyy</tt>, where <tt class="xph">xxx</tt> matches the RIPSS <span class="italic">Block number</span> and <tt class="xph">yyyyy</tt> matches the RIPSS <span class="italic">XID</span>.</p>
<p>For switched connections, the block number must be 005.</p></td>
</tr>
<tr>
<td align="left" valign="top" headers="wq160">Local location address</td>
<td align="left" valign="top" headers="wq161">LOCADR</td>
<td align="left" valign="top" headers="wq162">SNA Server Data, Session Data</td>
<td align="left" valign="top" headers="wq163"><span class="italic">LOC Address (Dec)</span>
<p>The values specified for the RIPSS configuration must match the values specified
on the LOCADR parameter of the CRTDEVRTL command.</p>
<p>Note that the RIPSS <span class="italic">LOC Address</span> is a decimal value; the iSeries value is
a 2-digit hexadecimal number.</p></td>
</tr>
<tr>
<td align="left" valign="top" headers="wq160">NRZI data encoding</td>
<td align="left" valign="top" headers="wq161">NRZI</td>
<td align="left" valign="top" headers="wq162">SDLC Server Data</td>
<td align="left" valign="top" headers="wq163"><span class="italic">Data coding/decoding</span>
<p>For SDLC connections, the values specified for the iSeries CRTLINSDLC
command and the RIPSS configuration must match: </p>
<ul>
<li>If the RIPSS response is <tt class="xph">NRZI</tt>, NRZI(*YES) must be specified
for the CRTLINSDLC command.</li>
<li>If the RIPSS response is <tt class="xph">NRZ</tt>, NRZI(*NO) must be specified for
the CRTLINSDLC command.</li></ul></td>
</tr>
<tr>
<td align="left" valign="top" headers="wq160">SSCP identifier</td>
<td align="left" valign="top" headers="wq161">SSCPID</td>
<td align="left" valign="top" headers="wq162">HST Server Data</td>
<td align="left" valign="top" headers="wq163"><span class="italic">SSCP Name</span>
<p>For
SDLC connections, if used, the value specified by the RIPSS configuration
must match the last 10 digits of the SSCPID parameter specified on the CRTCTLRTL
command.</p></td>
</tr>
<tr>
<td align="left" valign="top" headers="wq160">Station address</td>
<td align="left" valign="top" headers="wq161">STNADR</td>
<td align="left" valign="top" headers="wq162">SDLC Server Data</td>
<td align="left" valign="top" headers="wq163"><span class="italic">Poll address (hex)</span>
<p>For SDLC connections, values specified for the iSeries CRTCTLRTL command and the RIPSS configuration
must match.</p></td>
</tr>
</tbody>
</table>
<a id="Bot_Of_Page" name="Bot_Of_Page"></a>
</body>
</html>