ibm-information-center/dist/eclipse/plugins/i5OS.ic.rzajt_5.4.0.1/rzajtrzajtcfg400to400ctlrf.htm

175 lines
9.3 KiB
HTML

<?xml version="1.0" encoding="utf-8"?>
<!DOCTYPE html PUBLIC "-//W3C//DTD XHTML 1.0 Transitional//EN"
"http://www.w3.org/TR/xhtml1/DTD/xhtml1-transitional.dtd">
<html xmlns="http://www.w3.org/1999/xhtml" lang="en-US" xml:lang="en-us">
<head>
<meta http-equiv="Content-Type" content="text/html; charset=utf-8" />
<meta name="dc.language" scheme="rfc1766" content="en-us" />
<!-- All rights reserved. Licensed Materials Property of IBM -->
<!-- US Government Users Restricted Rights -->
<!-- Use, duplication or disclosure restricted by -->
<!-- GSA ADP Schedule Contract with IBM Corp. -->
<meta name="dc.date" scheme="iso8601" content="2005-09-06" />
<meta name="copyright" content="(C) Copyright IBM Corporation 1998, 2006" />
<meta name="security" content="public" />
<meta name="Robots" content="index,follow"/>
<meta http-equiv="PICS-Label" content='(PICS-1.1 "http://www.icra.org/ratingsv02.html" l gen true r (cz 1 lz 1 nz 1 oz 1 vz 1) "http://www.rsac.org/ratingsv01.html" l gen true r (n 0 s 0 v 0 l 0) "http://www.classify.org/safesurf/" l gen true r (SS~~000 1))' />
<title>Match iSeries system controller description parameters for a
remote iSeries system</title>
<link rel="stylesheet" type="text/css" href="ibmidwb.css" />
<link rel="stylesheet" type="text/css" href="ic.css" />
</head>
<body>
<a id="Top_Of_Page" name="Top_Of_Page"></a><!-- Java sync-link -->
<script language = "Javascript" src = "../rzahg/synch.js" type="text/javascript"></script>
<a name="rzajt-cfg400to400ctl-rf"></a>
<h3 id="rzajt-cfg400to400ctl-rf">Match iSeries system controller description parameters for a
remote iSeries system</h3>
<p>You must coordinate communications configuration parameters between local
and remote iSeries&trade; systems. The parameters are described in the following table.
This table shows those prompts and parameters that must be coordinated when
you specify controller descriptions for the local and remote iSeries systems.</p>
<p>To configure a local iSeries server to a remote iSeries server: </p>
<ul>
<li>See <a href="rzajtrzajtcfg400to400exre.htm#rzajt-cfg400to400ex-re">Connect one iSeries server to another iSeries server</a> for an example of connecting
one iSeries server to another iSeries server.</li>
<li>Use the following table for the controller descriptions.</li></ul>
<a name="wq48"></a>
<table id="wq48" width="100%" summary="" border="1" frame="border" rules="all" class="singleborder">
<thead valign="bottom">
<tr>
<th id="wq49" width="20%" align="center" valign="bottom">iSeries Prompt</th>
<th id="wq50" width="15%" align="center" valign="bottom">iSeries Parameter</th>
<th id="wq51" width="14%" align="center" valign="bottom">Remote iSeries Parameter</th>
<th id="wq52" width="49%" align="center" valign="bottom">Notes</th>
</tr>
</thead>
<tbody valign="top">
<tr>
<td align="left" valign="top" headers="wq49">local area network (LAN) remote adapter address</td>
<td align="left" valign="top" headers="wq50">ADPTADR</td>
<td align="left" valign="top" headers="wq51">ADPTADR</td>
<td align="left" valign="top" headers="wq52">The adapter address specified on the local
system controller description must match the line description ADPTADR parameter
specified by the remote system.
<p>If the iSeries system uses an Ethernet line through
an 8209 LAN Bridge, see "Appendix C: Local Area Network Addressing Considerations"
in the <a href="../books/c4154010.pdf" target="_blank">Communications Configuration</a>
<img src="wbpdf.gif" alt="Link to PDF" />book.</p></td>
</tr>
<tr>
<td align="left" valign="top" headers="wq49">Connection number</td>
<td align="left" valign="top" headers="wq50">CNNNBR</td>
<td align="left" valign="top" headers="wq51">NETADR</td>
<td align="left" valign="top" headers="wq52">For X.25 switched virtual circuits (SVCs),
the CNNNBR parameter on the local system controller description must match
the NETADR parameter on the line description for the remote system.</td>
</tr>
<tr>
<td align="left" valign="top" headers="wq49">Connection password</td>
<td align="left" valign="top" headers="wq50">CNNPWD</td>
<td align="left" valign="top" headers="wq51">CNNPWD</td>
<td align="left" valign="top" headers="wq52">For switched virtual circuits (SVCs), passwords
specified for each system must match.</td>
</tr>
<tr>
<td align="left" valign="top" headers="wq49">Destination service access point</td>
<td align="left" valign="top" headers="wq50">DSAP</td>
<td align="left" valign="top" headers="wq51">SSAP</td>
<td align="left" valign="top" headers="wq52">DSAP specified for the local iSeries server must
match the SSAP specified in the remote iSeries controller description.</td>
</tr>
<tr>
<td align="left" valign="top" headers="wq49">Exchange identifier</td>
<td align="left" valign="top" headers="wq50">EXCHID</td>
<td align="left" valign="top" headers="wq51">EXCHID</td>
<td align="left" valign="top" headers="wq52">If used, the local iSeries controller
description EXCHID must match the remote iSeries line description EXCHID. The first
three digits of the exchange identifier, known as the block number, is <tt class="xph">056</tt> for the iSeries line. You can use the WRKLIND command to determine
this value.</td>
</tr>
<tr>
<td align="left" valign="top" headers="wq49">Initial connection</td>
<td align="left" valign="top" headers="wq50">INLCNN</td>
<td align="left" valign="top" headers="wq51">INLCNN</td>
<td align="left" valign="top" headers="wq52">Values specified for each system must be
coordinated; INLCNN(*ANS) must not be specified for both systems.</td>
</tr>
<tr>
<td align="left" valign="top" headers="wq49">Link protocol</td>
<td align="left" valign="top" headers="wq50">LINKPCL</td>
<td align="left" valign="top" headers="wq51">LINKPCL</td>
<td align="left" valign="top" headers="wq52">For X.25 connections, values specified for
each system must match; both must be *QLLC or *ELLC.</td>
</tr>
<tr>
<td align="left" valign="top" headers="wq49">Remote control point name</td>
<td align="left" valign="top" headers="wq50">RMTCPNAME</td>
<td align="left" valign="top" headers="wq51">LCLCPNAME</td>
<td align="left" valign="top" headers="wq52">RMTCPNAME specified on the local iSeries system controller
description must match the local control point name specified in the network
attributes of the remote iSeries system.</td>
</tr>
<tr>
<td align="left" valign="top" headers="wq49">Remote network identifier</td>
<td align="left" valign="top" headers="wq50">RMTNETID</td>
<td align="left" valign="top" headers="wq51">LCLNETID</td>
<td align="left" valign="top" headers="wq52">RMTNETID specified on the local iSeries server controller
description must match the local network ID specified in the network attributes
of the remote iSeries server.</td>
</tr>
<tr>
<td align="left" valign="top" headers="wq49">Data link role</td>
<td align="left" valign="top" headers="wq50">ROLE</td>
<td align="left" valign="top" headers="wq51">ROLE</td>
<td align="left" valign="top" headers="wq52">The value specified for the local iSeries controller
description ROLE parameter must match the remote iSeries line description ROLE value.</td>
</tr>
<tr>
<td align="left" valign="top" headers="wq49">X.25 reverse charging</td>
<td align="left" valign="top" headers="wq50">RVSCRG</td>
<td align="left" valign="top" headers="wq51">RVSCRG</td>
<td align="left" valign="top" headers="wq52">Values specified for each system must be
coordinated.</td>
</tr>
<tr>
<td align="left" valign="top" headers="wq49">Switched network backup</td>
<td align="left" valign="top" headers="wq50">SNBU</td>
<td align="left" valign="top" headers="wq51">SNBU</td>
<td align="left" valign="top" headers="wq52">Values specified for each system must match.</td>
</tr>
<tr>
<td align="left" valign="top" headers="wq49">Source service access point</td>
<td align="left" valign="top" headers="wq50">SSAP</td>
<td align="left" valign="top" headers="wq51">DSAP</td>
<td align="left" valign="top" headers="wq52">SSAP specified for the local iSeries system must
match the DSAP specified in the remote iSeries controller description.</td>
</tr>
<tr>
<td align="left" valign="top" headers="wq49">Station address</td>
<td align="left" valign="top" headers="wq50">STNADR</td>
<td align="left" valign="top" headers="wq51">STNADR</td>
<td align="left" valign="top" headers="wq52">Values specified for each system must match,
unless both controller descriptions specify ROLE(*NEG).</td>
</tr>
<tr>
<td colspan="4" align="left" valign="top" headers="wq49 wq50 wq51 wq52">
<a name="wq53"></a>
<div class="notetitle" id="wq53">Note:</div>
<div class="notebody">For asynchronous controllers (CRTCTLASC command), if the remote system controller
description specifies RMTVFY(*YES), the local system controller description
must specify a local identifier (LCLID parameter) and local location name
(LCLLOCNAME parameter). The remote system must also create a configuration
list with the LCLID and LCLLOCNAME values from the local system controller
description.</div></td>
</tr>
</tbody>
</table>
<p>For more information on iSeries system parameters, see the <a href="../books/c4154010.pdf" target="_blank">Communications Configuration</a>
<img src="wbpdf.gif" alt="Link to PDF" /> book.</p>
<a id="Bot_Of_Page" name="Bot_Of_Page"></a>
</body>
</html>