ibm-information-center/dist/eclipse/plugins/i5OS.ic.rzahj_5.4.0.1/rzahjch4c.htm

67 lines
3.3 KiB
HTML

<?xml version="1.0" encoding="utf-8"?>
<!DOCTYPE html PUBLIC "-//W3C//DTD XHTML 1.0 Transitional//EN"
"http://www.w3.org/TR/xhtml1/DTD/xhtml1-transitional.dtd">
<html xmlns="http://www.w3.org/1999/xhtml" lang="en-US" xml:lang="en-us">
<head>
<meta http-equiv="Content-Type" content="text/html; charset=utf-8" />
<meta name="dc.language" scheme="rfc1766" content="en-us" />
<!-- All rights reserved. Licensed Materials Property of IBM -->
<!-- US Government Users Restricted Rights -->
<!-- Use, duplication or disclosure restricted by -->
<!-- GSA ADP Schedule Contract with IBM Corp. -->
<meta name="dc.date" scheme="iso8601" content="2005-10-03" />
<meta name="copyright" content="(C) Copyright IBM Corporation 1998, 2006" />
<meta name="security" content="public" />
<meta name="Robots" content="index,follow"/>
<meta http-equiv="PICS-Label" content='(PICS-1.1 "http://www.icra.org/ratingsv02.html" l gen true r (cz 1 lz 1 nz 1 oz 1 vz 1) "http://www.rsac.org/ratingsv01.html" l gen true r (n 0 s 0 v 0 l 0) "http://www.classify.org/safesurf/" l gen true r (SS~~000 1))' />
<title>Create the controller description (Chicago to Minneapolis) for two-system
APPN network with different IDs</title>
<link rel="stylesheet" type="text/css" href="ibmidwb.css" />
<link rel="stylesheet" type="text/css" href="ic.css" />
</head>
<body>
<a id="Top_Of_Page" name="Top_Of_Page"></a><!-- Java sync-link -->
<script language = "Javascript" src = "../rzahg/synch.js" type="text/javascript"></script>
<a name="ch4c"></a>
<h5 id="ch4c">Create the controller description (Chicago to Minneapolis) for two-system
APPN network with different IDs</h5>
<p>Because this is an APPN environment (iSeries system to iSeries system), the controller
is an APPC controller, and the CRTCTLAPPC command is used to define the attributes
of the controller. The example command defines the following attributes: </p>
<dl class="parml">
<dt class="bold">CTLD(MPLSL)</dt>
<dd>The name assigned to the controller description is MPLSL.
</dd>
<dt class="bold">LINKTYPE(*SDLC)</dt>
<dd>Because this controller is attached through an SDLC communications line,
the value specified is *SDLC. This value must correspond to the type of line
that is defined by a create line description command.
</dd>
<dt class="bold">LINE(MPLSL)</dt>
<dd>The name of the line description to which this controller is attached
is MPLSL. This value must match a name that is specified by the LIND parameter
in a line description.
</dd>
<dt class="bold">RMTNETID(APPN)</dt>
<dd>The name of the network in which the remote control point resides is
APPN.
</dd>
<dt class="bold">RMTCPNAME(MPLS)</dt>
<dd>The remote control-point name is MPLS. The name specified here must
match the name that is specified at the remote system for the local control-point
name. In the example, the name is specified at the remote system (MPLS) by
the LCLCPNAME parameter on the Change Network Attributes (CHGNETA) command.
</dd>
<dt class="bold">STNADR(01)</dt>
<dd>The address assigned to the remote controller is hex 01.
</dd>
<dt class="bold">NODETYPE(*NETNODE)</dt>
<dd>The remote system (MPLS) is an APPN network node.
</dd>
</dl>