ibm-information-center/dist/eclipse/plugins/i5OS.ic.rzahb_5.4.0.1/rzahbvaryonprocedure.htm

84 lines
5.5 KiB
HTML

<?xml version="1.0" encoding="UTF-8"?>
<!DOCTYPE html
PUBLIC "-//W3C//DTD XHTML 1.0 Transitional//EN" "http://www.w3.org/TR/xhtml1/DTD/xhtml1-transitional.dtd">
<html lang="en-us" xml:lang="en-us">
<head>
<meta http-equiv="Content-Type" content="text/html; charset=utf-8" />
<meta name="security" content="public" />
<meta name="Robots" content="index,follow" />
<meta http-equiv="PICS-Label" content='(PICS-1.1 "http://www.icra.org/ratingsv02.html" l gen true r (cz 1 lz 1 nz 1 oz 1 vz 1) "http://www.rsac.org/ratingsv01.html" l gen true r (n 0 s 0 v 0 l 0) "http://www.classify.org/safesurf/" l gen true r (SS~~000 1))' />
<meta name="DC.Type" content="task" />
<meta name="DC.Title" content="Recover when the console does not vary on" />
<meta name="abstract" content="Use this procedure to help resolve console vary-on problems." />
<meta name="description" content="Use this procedure to help resolve console vary-on problems." />
<meta name="DC.Relation" scheme="URI" content="rzahbflowchart.htm" />
<meta name="copyright" content="(C) Copyright IBM Corporation 1998, 2006" />
<meta name="DC.Rights.Owner" content="(C) Copyright IBM Corporation 1998, 2006" />
<meta name="DC.Format" content="XHTML" />
<meta name="DC.Identifier" content="rzahbvaryonprocedure" />
<meta name="DC.Language" content="en-us" />
<!-- All rights reserved. Licensed Materials Property of IBM -->
<!-- US Government Users Restricted Rights -->
<!-- Use, duplication or disclosure restricted by -->
<!-- GSA ADP Schedule Contract with IBM Corp. -->
<link rel="stylesheet" type="text/css" href="./ibmdita.css" />
<link rel="stylesheet" type="text/css" href="./ic.css" />
<title>Recover when the console does not vary on</title>
</head>
<body id="rzahbvaryonprocedure"><a name="rzahbvaryonprocedure"><!-- --></a>
<!-- Java sync-link --><script language="Javascript" src="../rzahg/synch.js" type="text/javascript"></script>
<h1 class="topictitle1">Recover when the console does not vary on</h1>
<div><p>Use this procedure to help resolve console vary-on problems.</p>
<div class="section">If the system is logically partitioned, references to the system,
console, displays, system commands, and system values are relative to the
partition having a problem. References to the control panel refer to the "Work
with partition" status display functions if the problem is in a secondary
partition, or the actual control panel if the problem is in the primary partition.</div>
<ol><li class="stepexpand"><span>Locate the workstation that is used as the primary console. See <a href="rzahb_determine_console.htm#rzahb_determine_console">Determine the primary or alternative consoles</a>.</span></li>
<li class="stepexpand"><span>Make sure the workstation cables are attached correctly and set
to the correct address.</span></li>
<li class="stepexpand"><span>Can you sign on to an alternative console?</span> <ul><li><span class="uicontrol">Yes</span>: Continue with the next step.</li>
<li><span class="uicontrol">No</span>: Go to step <a href="#rzahbvaryonprocedure__varyon_05">5</a>.</li>
</ul>
</li>
<li class="stepexpand"><span>If you can sign on to an alternative console, perform the following
steps:</span> <ol type="a"><li>Make sure the primary console controller (for example, CTL01) and device
description (for example, DSP01) have been created or restored. To check the
device description, use the command WRKCFGSTS *CTL.</li>
<li>If descriptions exist, check the system operator message to determine
why the primary console failed. </li>
<li>Take corrective actions indicated in the message.</li>
<li>If you still cannot solve the problem, set the system to the Normal mode
and call your software service representative.</li>
</ol>
</li>
<li class="stepexpand" id="rzahbvaryonprocedure__varyon_05"><a name="rzahbvaryonprocedure__varyon_05"><!-- --></a><span>If you cannot sign on to an alternative console,
perform the following steps:</span> <ol type="a"><li>Set the system to the <span class="uicontrol">Manual</span> mode,
select <span class="uicontrol">function 3</span>, and press Enter to start an IPL.
You will see the IPL Option display.</li>
<li>Were you able to get to the IPL Option display? <ul><li><span class="uicontrol">No</span>: Contact your hardware service provider.</li>
<li><span class="uicontrol">Yes</span>: On the IPL Options display, specify <span class="uicontrol">Y</span> (Yes)
in the Define or change system at IPL field, <span class="uicontrol">N</span> (No)
in the Set major system option field and press Enter. The Configuration Commands
menu appears.</li>
</ul>
</li>
<li>Select <span class="uicontrol">option 2</span> (Controller description commands)
to see the controller description for the console. Verify that the controller
(for example, CTL01) was created correctly. If the name has been changed,
see <a href="rzahb_determine_console.htm#rzahb_determine_console__find_operational">Find
the primary console when the system is operational</a> in this topic.</li>
<li>Select <span class="uicontrol">option 3</span> (Device description commands) to
see the device description for the console. Verify that the device (for example,
DSP01) was created correctly. If the name has been changed, see <a href="rzahb_determine_console.htm#rzahb_determine_console__find_operational">Find the primary console when the system is operational</a> in this topic.</li>
</ol>
</li>
</ol>
</div>
<div>
<div class="familylinks">
<div class="parentlink"><strong>Parent topic:</strong> <a href="rzahbflowchart.htm" title="You can often solve problems that occur on your system with methodical analysis.">Problem analysis procedures</a></div>
</div>
</div>
</body>