166 lines
12 KiB
HTML
166 lines
12 KiB
HTML
<?xml version="1.0" encoding="UTF-8"?>
|
|
<!DOCTYPE html
|
|
PUBLIC "-//W3C//DTD XHTML 1.0 Transitional//EN" "http://www.w3.org/TR/xhtml1/DTD/xhtml1-transitional.dtd">
|
|
<html lang="en-us" xml:lang="en-us">
|
|
<head>
|
|
<meta http-equiv="Content-Type" content="text/html; charset=utf-8" />
|
|
<meta name="security" content="public" />
|
|
<meta name="Robots" content="index,follow" />
|
|
<meta http-equiv="PICS-Label" content='(PICS-1.1 "http://www.icra.org/ratingsv02.html" l gen true r (cz 1 lz 1 nz 1 oz 1 vz 1) "http://www.rsac.org/ratingsv01.html" l gen true r (n 0 s 0 v 0 l 0) "http://www.classify.org/safesurf/" l gen true r (SS~~000 1))' />
|
|
<meta name="DC.Type" content="reference" />
|
|
<meta name="DC.Title" content="iSeries source to System/36 target considerations for DDM" />
|
|
<meta name="abstract" content="When an iSeries server is using DDM to communicate as a source server to access files on a System/36 target server, the information in this topic applies and should be considered." />
|
|
<meta name="description" content="When an iSeries server is using DDM to communicate as a source server to access files on a System/36 target server, the information in this topic applies and should be considered." />
|
|
<meta name="DC.subject" content="target DDM (TDDM), System/36, TDDM (target DDM), DDM target considerations, source DDM (SDDM), server, iSeries, SDDM (source DDM), DDM source considerations, as source, system, AS/400, deleted records, file, extensions, sequential file, extension support, ILE COBOL programming language, extending, ILE RPG programming language, indexed, sequential processing," />
|
|
<meta name="keywords" content="target DDM (TDDM), System/36, TDDM (target DDM), DDM target considerations, source DDM (SDDM), server, iSeries, SDDM (source DDM), DDM source considerations, as source, system, AS/400, deleted records, file, extensions, sequential file, extension support, ILE COBOL programming language, extending, ILE RPG programming language, indexed, sequential processing," />
|
|
<meta name="DC.Relation" scheme="URI" content="rbae5source36.htm" />
|
|
<meta name="copyright" content="(C) Copyright IBM Corporation 1999, 2006" />
|
|
<meta name="DC.Rights.Owner" content="(C) Copyright IBM Corporation 1999, 2006" />
|
|
<meta name="DC.Format" content="XHTML" />
|
|
<meta name="DC.Identifier" content="rbae5considerations" />
|
|
<meta name="DC.Language" content="en-us" />
|
|
<!-- All rights reserved. Licensed Materials Property of IBM -->
|
|
<!-- US Government Users Restricted Rights -->
|
|
<!-- Use, duplication or disclosure restricted by -->
|
|
<!-- GSA ADP Schedule Contract with IBM Corp. -->
|
|
<link rel="stylesheet" type="text/css" href="./ibmdita.css" />
|
|
<link rel="stylesheet" type="text/css" href="./ic.css" />
|
|
<title>iSeries source to System/36 target considerations for DDM</title>
|
|
</head>
|
|
<body id="rbae5considerations"><a name="rbae5considerations"><!-- --></a>
|
|
<!-- Java sync-link --><script language="Javascript" src="../rzahg/synch.js" type="text/javascript"></script>
|
|
<h1 class="topictitle1"><span class="keyword">iSeries</span> source to <span class="keyword">System/36</span> target considerations for DDM</h1>
|
|
<div><p>When an <span class="keyword">iSeries™ server</span> is
|
|
using DDM to communicate as a source server to access files on a <span class="keyword">System/36™</span> target server, the information
|
|
in this topic applies and should be considered.</p>
|
|
<div class="section"><ul><li>Some file operations that are not rejected by a target <span class="keyword">iSeries server</span> might
|
|
be rejected by a target <span class="keyword">System/36</span>.
|
|
Examples are: <ul><li>A delete record operation is rejected if the <span class="keyword">System/36</span> file
|
|
is not a delete-capable file. To the <span class="keyword">iSeries</span> source
|
|
user, the rejection might appear to occur for unknown reasons.</li>
|
|
<li>Change operation that attempts to change the key in the primary index
|
|
of a <span class="keyword">System/36</span> file is always
|
|
rejected.</li>
|
|
</ul>
|
|
</li>
|
|
<li>In the <span class="keyword">System/36</span> environment,
|
|
when <span class="keyword">System/36</span> users try to
|
|
copy a delete-capable file to a file that is not delete-capable with the NOREORG
|
|
parameter, a warning message is issued stating that deleted records might
|
|
be copied. The user can choose option 0 (Continue) to continue the process.
|
|
By selecting this option, the file is copied and any deleted records in the
|
|
input file become active records in the output file. An <span class="keyword">iSeries server</span> rejects
|
|
the copy request if the user specifies COMPRESS(*NO).</li>
|
|
<li>If data is copied to a target <span class="keyword">System/36</span> file
|
|
that is a direct file and is not delete-capable, default values
|
|
for all <span class="cmdname">Copy File (CPYF)</span> command parameters except FROMMBR,
|
|
TOMBR, and MBROPT must be specified.</li>
|
|
<li>An <span class="keyword">iSeries server</span> does not support
|
|
the overwriting of data on the Delete File (DLTF) command. If an <span class="keyword">iSeries</span> user accessing a <span class="keyword">System/36</span> wants
|
|
to overwrite the data, an application program must be written on the <span class="keyword">iSeries server</span>, or the user must access the
|
|
target <span class="keyword">System/36</span> and perform
|
|
the overwrite operation.</li>
|
|
<li>Depending on how a <span class="keyword">System/36</span> file
|
|
is originally created, the maximum number of records it can contain is approximately
|
|
eight million. This number can be significantly smaller if the file is not
|
|
extendable or if sufficient storage space is not available to extend the file
|
|
to add more records.</li>
|
|
<li><span class="keyword">System/36</span> supports a maximum
|
|
of three key definitions for logical files and one key definition for keyed
|
|
physical files.</li>
|
|
<li><span class="keyword">System/36</span> file support does
|
|
not allow a file with active logical files to be cleared. When some <span class="keyword">iSeries</span> programs (like ILE COBOL programs)
|
|
open a file for output only, a command to clear the file is issued. A target <span class="keyword">System/36</span> rejects any such command to
|
|
clear the file if a logical file exists over the file to be cleared.</li>
|
|
<li><span class="keyword">System/36</span> file support automatically
|
|
skips deleted records. If an <span class="keyword">iSeries</span> source
|
|
user wishes to change the records in a <span class="keyword">System/36</span> base
|
|
file over which at least one logical file has been built, the file must be
|
|
opened in I/O mode, specifying direct organization and random access by record
|
|
number. Then each record can be read by record number and changed. If a deleted
|
|
record is found, a record-not-found indication is returned, and the record
|
|
might be written rather than rewritten for that position (write operation
|
|
rather than a change operation).</li>
|
|
<li>System/36 file
|
|
support also handles file extensions differently, depending on the file type
|
|
and the language being used. However, an <span class="keyword">iSeries</span> user
|
|
cannot extend any type of <span class="keyword">System/36</span> file
|
|
unless the access method used to access the file is similar to the method
|
|
used when the file was created. <p>If an <span class="keyword">iSeries</span> user
|
|
is accessing a <span class="keyword">System/36</span> file
|
|
with an access method similar to the one used to create the file, the file
|
|
can be extended during its use in the following manner: </p>
|
|
<ul><li>If the file was created as a <em>sequential</em> file, the <span class="keyword">iSeries</span> user
|
|
should, if the <span class="keyword">iSeries</span> language
|
|
is: <ul><li>ILE COBOL programming language: open the file using the EXTEND option.</li>
|
|
<li>PL/I: open the file using the UPDATE option. Perform a read operation
|
|
using the POSITION option of LAST, and then perform the write operations.</li>
|
|
</ul>
|
|
</li>
|
|
</ul>
|
|
<p>(BASIC and ILE RPG programming language both handle any needed file
|
|
extensions automatically.)</p>
|
|
</li>
|
|
<li>If the file was created as a <em>direct</em> file, the <span class="keyword">iSeries</span> user
|
|
should, if the <span class="keyword">iSeries</span> language
|
|
is: <ul><li>ILE COBOL programming language: open the file using the I-O option, position
|
|
the end of file pointer to the end of the file (using, for example, READ LAST),
|
|
and perform a write operation.</li>
|
|
<li>PL/I: open the file using the UPDATE option, position the end of file
|
|
(EOF) pointer to the end of the file (using, for example, READ LAST), and
|
|
perform a write operation. <p>(BASIC and ILE RPG programming language both
|
|
handle any needed file extensions automatically.)</p>
|
|
</li>
|
|
<li>If the file was created as an <em>indexed</em> file, the file is extended
|
|
each time a write operation is performed for a record having a key that does
|
|
not already exist in the file.</li>
|
|
</ul>
|
|
</li>
|
|
<li> The <span class="keyword">iSeries</span> user can access
|
|
sequential <span class="keyword">System/36</span> files using
|
|
either sequential or direct (by relative record number) methods, but significant
|
|
differences occur when EOF or end of data occurs. If a <span class="keyword">System/36</span> sequential
|
|
file is being processed using relative record number access and is opened
|
|
for either input/output or output only, then, on reaching the end of active
|
|
records (EOF), you cannot add new records in the available free space beyond
|
|
the end of data. You will have to close and reopen the file to extend it.
|
|
To extend the file, you can either reopen it as a sequential file or open
|
|
a logical file that uses this file as the base file.</li>
|
|
<li>Because the normal access method used for a <span class="keyword">System/36</span> file
|
|
can be changed by <span class="keyword">iSeries</span> parameters
|
|
to values other than *RMTFILE, it is possible that DDM might attempt to access
|
|
the <span class="keyword">System/36</span> file in ways that
|
|
the <span class="keyword">System/36</span> might not support.
|
|
Normally, the default value (*RMTFILE) on the ACCMTH parameter gives the user
|
|
the needed method of access. The use of access methods not normally expected
|
|
(such as direct or sequential access to indexed files, or sequential access
|
|
to direct files) requires the use of an ACCMTH parameter explicitly for the
|
|
access. <p>The normal access method used for a <span class="keyword">System/36</span> file
|
|
can be changed on the <span class="keyword">iSeries server</span>:
|
|
by the ACCMTH parameter of the DDM file commands <span class="cmdname">Create DDM File
|
|
(CRTDDMF)</span> and <span class="cmdname">Change DDM File (CHGDDMF)</span>, by the
|
|
SEQONLY parameter of the <span class="cmdname">Override with Database File (OVRDBF)</span> command,
|
|
or by using the <span class="cmdname">OVRDBF</span> command to override one DDM file
|
|
with another DDM file having a different ACCMTH value in effect.</p>
|
|
</li>
|
|
<li>The <span class="keyword">iSeries</span> user can access
|
|
a <span class="keyword">System/36</span> file using a member
|
|
name if the member name is *FIRST, or in some cases *LAST, or if the file
|
|
name is the same as the member name.</li>
|
|
<li>Target <span class="keyword">System/36</span> DDM cannot
|
|
support creating logical files with duplicate (nonunique) keys, because the <span class="keyword">System/36</span> local data management key sort
|
|
sends messages to the target server console with options 1 or 3 when duplicate
|
|
keys are detected. This forces the target system operator either to change
|
|
the file attributes to allow duplicate keys or to cancel the target data manager.
|
|
<div class="note"><span class="notetitle">Note:</span> Never cancel the target data manager using a SYSLOG HALT.</div>
|
|
</li>
|
|
</ul>
|
|
</div>
|
|
</div>
|
|
<div>
|
|
<div class="familylinks">
|
|
<div class="parentlink"><strong>Parent topic:</strong> <a href="rbae5source36.htm" title="Before an iSeries server can access files on a System/36, Level 1.0 of the DDM architecture must be installed on the System/36. These topics contain information that applies when an iSeries server is the source or target server communicating with a System/36.">System/36 source and target considerations for DDM</a></div>
|
|