<h2>Cancel RJE Reader (CNLRJERDR)</h2>
<table width="100%">
<tr>
<td valign="top" align="left"><b>Where allowed to run: </b>All environments (*ALL)<br>
<b>Threadsafe: </b>No
</td>
<td valign="top" align="right">
<a href="#CNLRJERDR.PARAMETERS.TABLE">Parameters</a><br>
<a href="#CNLRJERDR.COMMAND.EXAMPLES">Examples</a><br>
<a href="#CNLRJERDR.ERROR.MESSAGES">Error messages</a></td>
</tr>
</table>
<div> <a name="CNLRJERDR"></a>
<h3>Cancel RJE Reader</h3>
<p>The CNLRJERDR command cancels a reader job and holds the associated reader job queue.
</p>
<h3>Error messages for CNLRJERDR</h3>
<p><b><u>*ESCAPE Messages</u></b>
</p>
<dl>
<dt><b>RJE0003</b></dt>
<dd>RJE session &amp;1 is not active.
</dd>
<dt><b>RJE0004</b></dt>
<dd>You are not permitted to access session description &amp;1.
</dd>
<dt><b>RJE0024</b></dt>
<dd>Errors found. Processing of request ended.
</dd>
<dt><b>RJE0063</b></dt>
<dd>RJE session &amp;1 is already ending.
</dd>
<dt><b>RJE0143</b></dt>
<dd>No RJE readers were defined for this RJE session.
</dd>
<dt><b>RJE0144</b></dt>
<dd>RJE device &amp;3 was not defined in RJE session &amp;1.
</dd>
<dt><b>RJE0145</b></dt>
<dd>You do not have authority to library QRECOVERY.
</dd>
<dt><b>RJE0146</b></dt>
<dd>You do not have authority to message queue &amp;1.
</dd>
</dl>
</div>
<table width="100%">
<tr><td align="right"><a href="#CNLRJERDR.Top_Of_Page">Top</a></td></tr>
</table>
<hr size="2" width="100%">
<div>
<h3><a name="CNLRJERDR.PARAMETERS.TABLE">Parameters</a></h3>
<table border="1" cellpadding="4" cellspacing="0">
<!-- col1="10" col2="15" col3="30" col4="10" -->
<tr>
<th bgcolor="aqua" valign="bottom" align="left">Keyword</th>
<th bgcolor="aqua" valign="bottom" align="left">Description</th>
<th bgcolor="aqua" valign="bottom" align="left">Choices</th>
<th bgcolor="aqua" valign="bottom" align="left">Notes</th>
</tr>
<tr>
<td valign="top"><a href="#CNLRJERDR.RDR"><b>RDR</b></a></td>
<td valign="top">RJE reader identification</td>
<td valign="top">*ALL, RD1, RD2, RD3, RD4, RD5, RD6, RD7, RD8, RD9, RD10, RD11, RD12, RD13, RD14, RD15</td>
<td valign="top">Required, Positional 1</td>
</tr>
<tr>
<td valign="top"><a href="#CNLRJERDR.SSN"><b>SSN</b></a></td>
<td valign="top">Active RJE session</td>
<td valign="top"><i>Name</i></td>
<td valign="top">Required, Positional 2</td>
</tr>
<tr>
<td valign="top"><a href="#CNLRJERDR.OPTION"><b>OPTION</b></a></td>
<td valign="top">Cancel</td>
<td valign="top"><b><u>*CNTRLD</u></b>, *IMMED</td>
<td valign="top">Optional, Positional 3</td>
</tr>
</table>
<table width="100%">
<tr><td align="right"><a href="#CNLRJERDR.Top_Of_Page">Top</a></td></tr>
</table>
</div>
<div> <a name="CNLRJERDR.RDR"></a>
<h3>RJE Reader ID (RDR)</h3>
<p>Specifies the name of the reader to be canceled.
</p>
<p>The possible values are:
</p>
<ul>
<li>*ALL: All readers in the session are canceled.
</li>
<li>RD1 - RD15: A reader ID, between RD1 and RD15, is canceled.
</li>
</ul>
</div>
<table width="100%">
<tr><td align="right"><a href="#CNLRJERDR.Top_Of_Page">Top</a></td></tr>
</table>
<div> <a name="CNLRJERDR.SSN"></a>
<h3>Active RJE Session (SSN)</h3>
<p>Specifies the session that contains the reader being canceled.
</p>
</div>
<table width="100%">
<tr><td align="right"><a href="#CNLRJERDR.Top_Of_Page">Top</a></td></tr>
</table>
<div> <a name="CNLRJERDR.OPTION"></a>
<h3>Cancel (OPTION)</h3>
<p>Specifies how the reader is canceled. The STRRJERDR command must be issued to continue RJE reader operations.
</p>
<p>The possible values are:
</p>
<ul>
<li>*CNTRLD: The reader ends processing in a controlled manner by holding the job queue associated with the reader. A controlled ending prevents new reader jobs from running, and allows the job currently running to complete normally.
</li>
<li>*IMMED: The reader ends processing immediately. No more data records are sent to the host subsystem, and no new reader jobs are allowed to start. For SNA, an end-abort function management header (FMH) is sent to the host subsystem. For BSC, a normal end-of-file sequence is sent to the host subsystem.
</li>
</ul>
</div>
<table width="100%">
<tr><td align="right"><a href="#CNLRJERDR.Top_Of_Page">Top</a></td></tr>
</table>
<hr size="2" width="100%">
<div>
<h3><a name="CNLRJERDR.COMMAND.EXAMPLES">Examples</a></h3>None
</div>
<table width="100%">
<tr><td align="right"><a href="#CNLRJERDR.Top_Of_Page">Top</a></td></tr>
</table>
<hr size="2" width="100%">
<div><h3><a name="CNLRJERDR.ERROR.MESSAGES">Error messages</a> </h3>
<p><b><u>*ESCAPE Messages</u></b>
</p>
<dl>
<dt><b>RJE0003</b></dt>
<dd>RJE session &amp;1 is not active.
</dd>
<dt><b>RJE0004</b></dt>
<dd>You are not permitted to access session description &amp;1.
</dd>
<dt><b>RJE0024</b></dt>
<dd>Errors found. Processing of request ended.
</dd>
<dt><b>RJE0063</b></dt>
<dd>RJE session &amp;1 is already ending.
</dd>
<dt><b>RJE0143</b></dt>
<dd>No RJE readers were defined for this RJE session.
</dd>
<dt><b>RJE0144</b></dt>
<dd>RJE device &amp;3 was not defined in RJE session &amp;1.
</dd>
<dt><b>RJE0145</b></dt>
<dd>You do not have authority to library QRECOVERY.
</dd>
<dt><b>RJE0146</b></dt>
<dd>You do not have authority to message queue &amp;1.
</dd>
</dl>