<meta name="DC.Type" content="task" />
|
|
<meta name="DC.Title" content="Disconnect all jobs from a device" />
|
|
<meta name="abstract" content="The Disconnect Job (DSCJOB) command allows the interactive user to disconnect all interactive jobs at the workstation and return to the signon display. The switched line is dropped only if that is specified in the workstation device description of this workstation and if no other workstation on this line is active. If the job is disconnected when the disconnect interval in the Time-out interval for disconnected jobs (QDSCJOBITV) system value is reached, the job is ended and the job log is not included with the job's spooled output." />
|
|
<meta name="description" content="The Disconnect Job (DSCJOB) command allows the interactive user to disconnect all interactive jobs at the workstation and return to the signon display. The switched line is dropped only if that is specified in the workstation device description of this workstation and if no other workstation on this line is active. If the job is disconnected when the disconnect interval in the Time-out interval for disconnected jobs (QDSCJOBITV) system value is reached, the job is ended and the job log is not included with the job's spooled output." />
|
|
<meta name="DC.Relation" scheme="URI" content="rzaksmanageintjobs.htm" />
|
|
<meta name="DC.Relation" scheme="URI" content="rzakshowintjobend.htm" />
|
|
<meta name="copyright" content="(C) Copyright IBM Corporation 2004-2006" />
|
|
<meta name="DC.Rights.Owner" content="(C) Copyright IBM Corporation 2004-2006" />
|
|
<meta name="DC.Format" content="XHTML" />
|
|
<meta name="DC.Identifier" content="rzaksdisconnectalljobs" />
|
|
<meta name="DC.Language" content="en-us" />
|
|
<!-- All rights reserved. Licensed Materials Property of IBM -->
|
|
<!-- US Government Users Restricted Rights -->
|
|
<!-- Use, duplication or disclosure restricted by -->
|
|
<!-- GSA ADP Schedule Contract with IBM Corp. -->
|
|
<link rel="stylesheet" type="text/css" href="./ibmdita.css" />
|
|
<link rel="stylesheet" type="text/css" href="./ic.css" />
|
|
<title>Disconnect all jobs from a device</title>
|
|
</head>
|
|
<body id="rzaksdisconnectalljobs"><a name="rzaksdisconnectalljobs"><!-- --></a>
|
|
<!-- Java sync-link --><script language="Javascript" src="../rzahg/synch.js" type="text/javascript"></script>
|
|
<h1 class="topictitle1">Disconnect all jobs from a device</h1>
|
|
<div><p>The Disconnect Job (<span class="cmdname">DSCJOB</span>) command allows the
|
|
interactive user to disconnect all interactive jobs at the workstation and
|
|
return to the signon display. The switched line is dropped only if that is
|
|
specified in the workstation device description of this workstation and if
|
|
no other workstation on this line is active. If the job is disconnected when
|
|
the disconnect interval in the Time-out interval for disconnected jobs (QDSCJOBITV)
|
|
system value is reached, the job is ended and the job log is
|
|
not included with the job's spooled output. </p>
|
|
<div class="p">Restrictions:<ol><li>A job being disconnected must be an interactive job. </li>
|
|
<li>A job which is being held cannot be disconnected. </li>
|
|
<li>A pass-through job cannot be disconnected unless the user has used the
|
|
system request function to return to the source system from the pass-through
|
|
target system. </li>
|
|
<li>The command must be issued from within the job being disconnected, or
|
|
the issuer of the command must be running under a user profile which is the
|
|
same as the job user identity of the job being disconnected, or the issuer
|
|
of the command must be running under a user profile which has job control
|
|
(*JOBCTL) special authority.</li>
|
|
<li> The job user identity is the name of the user profile by which a job
|
|
is known to other jobs. </li>
|
|
<li>A job cannot be disconnected if PC organizer is active. </li>
|
|
</ol>
|
|
</div>
|
|
<div class="section"><strong>Command: </strong> Disconnect Job (<span class="cmdname">DSCJOB</span>)</div>
|
|
</div>
|
|
<div>
|
|
<div class="familylinks">
|
|
<div class="parentlink"><strong>Parent topic:</strong> <a href="rzaksmanageintjobs.htm" title="An interactive job starts when you sign on to the system or, transfer to a secondary or group job. The interactive job ends when you sign off. Working from a display station, you interact with the system by issuing commands, using function keys, and running programs and applications. The following information discusses the various methods for managing and controlling interactive jobs.">Manage interactive jobs</a></div>
|
|
</div>
|
|
<div class="relconcepts"><strong>Related concepts</strong><br />
|
|
<div><a href="rzakshowintjobend.htm" title="When the Disconnect Job (DSCJOB) command is called, the job is disconnected and the signon display is shown again. To connect with the job again, sign on to the same device from which you disconnected. Another interactive job may be started on the device under a different user name.">Disconnect interactive jobs</a></div>
|
|
</div>
|
|
</div>
|
|
</body>
|
|
</html> |