<meta name="DC.Title" content="Extended control panel functions" />
<meta name="abstract" content="The system enables service functions 50 through 70 when you select manual mode and enter function 25 (service switch 1), then function 26 (service switch 2). You use subfunctions with Functions 51 and 57 through 64." />
<meta name="description" content="The system enables service functions 50 through 70 when you select manual mode and enter function 25 (service switch 1), then function 26 (service switch 2). You use subfunctions with Functions 51 and 57 through 64." />
<meta name="DC.Relation" scheme="URI" content="rzatmcpfdc.htm" />
<meta name="copyright" content="(C) Copyright IBM Corporation 2000, 2006" />
<meta name="DC.Rights.Owner" content="(C) Copyright IBM Corporation 2000, 2006" />
<meta name="DC.Format" content="XHTML" />
<meta name="DC.Identifier" content="rzatmextfunc" />
<meta name="DC.Language" content="en-us" />
<!-- All rights reserved. Licensed Materials Property of IBM -->
<!-- US Government Users Restricted Rights -->
<!-- Use, duplication or disclosure restricted by -->
<!-- GSA ADP Schedule Contract with IBM Corp. -->
<link rel="stylesheet" type="text/css" href="./ibmdita.css" />
<link rel="stylesheet" type="text/css" href="./ic.css" />
<title>Extended control panel functions</title>
</head>
<body id="rzatmextfunc"><a name="rzatmextfunc"><!-- --></a>
<!-- Java sync-link --><script language="Javascript" src="../rzahg/synch.js" type="text/javascript"></script>
<h1 class="topictitle1">Extended control panel functions</h1>
<div><p>The system enables service functions 50 through 70 when you select
manual mode and enter function 25 (service switch 1), then function 26 (service
switch 2). You use <span class="uicontrol">subfunctions</span> with Functions 51 and
57 through 64.</p>
<div class="section"><div class="note"><span class="notetitle">Notes:</span> <ol><li>When a function has no data to display, <samp class="codeph">FF</samp> is shown.</li>
<li>Some upper functions, 50 through 70, are not supported using the remote
control panel and virtual control panel, depending on connectivity.</li>
<li>Non-supported functions for the remote control panel and virtual control
panel display <samp class="codeph">FF</samp>.</li>
</ol>
</div>
</div>
<div class="section"><p>To enable functions 50 through 70:</p>
<ol><li>Select function 25 and press Enter. The display reads <samp class="codeph">25 00</samp>.</li>
<li><img src="./delta.gif" alt="Start of change" />Use the Increment button to select function 26
and press Enter. The display briefly reads <samp class="codeph">26 00</samp>. Then it
typically displays <samp class="codeph">01 B</samp> when the upper functions have activated.<img src="./deltaend.gif" alt="End of change" /></li>
</ol>
<p>Functions 50 through 70 are now available.</p>
<p>You can disable the
service functions by selecting and entering either function 25 (service switch
1) or function 26 (service switch 2).</p>
<p>To disable functions 50 through
70, select function 25 and press Enter. Functions 50 through 70 are then no
longer available.</p>
<p><strong>Using Subfunctions</strong></p>
<p>To work with subfunctions,
do the following:</p>
<ol><li>Use the Increment or Decrement button to select the appropriate function
and press Enter. The function number appears with asterisks (**); for example,
<samp class="codeph">57**</samp>. The two asterisks indicate that subfunctions are available.</li>
<li>Press the Increment button. The first subfunction number appears; for
example, <samp class="codeph">5700</samp>.</li>
<li>As the subfunction number is displayed, press Enter. The system displays
data associated with the subfunction number.</li>
<li>Press the Increment button. The next subfunction number appears; for example,
<samp class="codeph">5701</samp>.</li>
<li>As the subfunction number is displayed, press Enter. The system displays
the data associated with the new subfunction number.</li>
<li>Repeat these steps to gather all the data that is associated with the
subfunction.</li>
<li>Use the Increment or Decrement button to return to the function display
with asterisks; for example <samp class="codeph">57**</samp>.</li>
<li>Press Enter to exit the subfunctions.</li>
</ol>
<p><strong>Function 50-System Processor Stop</strong></p>
<p>This function stops
the system processor.</p>
<div class="attention"><span class="attentiontitle">Attention:</span> This function might cause
the system to end abnormally. Use only when directed by your next level of
support.</div>
<p><strong>Function 51-System Processor Status</strong></p>
<p>This function
displays the following values:</p>
<ul><li>Next instruction address (NIA)</li>
<li>Current task dispatching element (TDE) address</li>
</ul>
<p>The data can be displayed 8 digits at a time. Select and enter a subfunction
number to display each word of data from 00 to 0F.</p>
<p>The following table
is an example of a subfunction data display that shows NIA and TDE information.</p>
<p><strong>Subfunction
data display example </strong> </p>
<div class="tablenoborder"><table cellpadding="4" cellspacing="0" summary="" frame="border" border="1" rules="all"><thead align="left"><tr><th valign="top" id="d0e119"> Function</th>
<th valign="top" id="d0e121"> Subfunction</th>
<th valign="top" id="d0e123">Data Display</th>
</tr>
</thead>
<tbody><tr><td valign="top" headers="d0e119 ">51</td>
<td valign="top" headers="d0e121 ">**</td>
<td valign="top" headers="d0e123 "> Subfunction mode entered</td>
</tr>
<tr><td valign="top" headers="d0e119 ">51</td>
<td valign="top" headers="d0e121 ">00, 01</td>
<td valign="top" headers="d0e123 ">NIA (8 bytes)</td>
</tr>
<tr><td valign="top" headers="d0e119 ">51</td>
<td valign="top" headers="d0e121 ">02, 03</td>
<td valign="top" headers="d0e123 ">Current TDE (8 bytes)</td>
</tr>
</tbody>
</table>
</div>
<p><strong>Function 52-System Processor Start</strong></p>
<p>This function starts
the system processor (after it has stopped).</p>
<p><strong>Function 53- Repeat
GARD</strong></p>
<p>This function displays the following values:</p>
<ul><li>Clear memory, processor, L3 repeat GARD</li>
<li>Enable memory, processor, L3 repeat GARD</li>
<li>Disable memory, processor, L3 repeat GARD</li>
<li>View enable/disable status</li>
</ul>
<p>This function permanently de-configures an intermittently failing
processor, during the IPL following the failure. This is performed in case
the IPL diagnostics cannot detect the failure and automatically de-configure
it. The failing processor must be replaced or the Repeat GARD function must
be cleared before that processor can be used again.</p>
<div class="attention"><span class="attentiontitle">Attention:</span> This
function can cause a good processor to be permanently de-configured following
a power failure. Use only when directed by your next level of support.</div>
<p>The
following table is an example of a subfunction data display that shows Repeat
GARD information.</p>
<p><strong>Subfunction data display example</strong></p>
<div class="tablenoborder"><table cellpadding="4" cellspacing="0" summary="" frame="border" border="1" rules="all"><thead align="left"><tr><th valign="top" id="d0e182">Function</th>
<th valign="top" id="d0e184">Subfunction</th>
<th valign="top" id="d0e186">Data Display</th>
</tr>
</thead>
<tbody><tr><td valign="top" headers="d0e182 ">53</td>
<td valign="top" headers="d0e184 ">**</td>
<td valign="top" headers="d0e186 "> Subfunction mode entered</td>
</tr>
<tr><td valign="top" headers="d0e182 ">53</td>
<td valign="top" headers="d0e184 ">00</td>
<td valign="top" headers="d0e186 ">Clear memory, processor, L3 repeat GARD</td>
</tr>
<tr><td valign="top" headers="d0e182 ">53</td>
<td valign="top" headers="d0e184 ">01</td>
<td valign="top" headers="d0e186 ">Enable memory, processor, L3 Repeat GARD</td>
</tr>
<tr><td valign="top" headers="d0e182 ">53</td>
<td valign="top" headers="d0e184 ">02</td>
<td valign="top" headers="d0e186 ">Disable memory, processor, L3 Repeat GARD</td>
</tr>
<tr><td valign="top" headers="d0e182 ">53</td>
<td valign="top" headers="d0e184 ">03</td>
<td valign="top" headers="d0e186 ">View enable/disable status (E=Enabled, D=Disabled)</td>
</tr>