ibm-information-center/dist/eclipse/plugins/i5OS.ic.rzamd_5.4.0.1/rzamdplanexpanupgradelpar.htm

98 lines
6.8 KiB
HTML
Raw Permalink Blame History

This file contains invisible Unicode characters

This file contains invisible Unicode characters that are indistinguishable to humans but may be processed differently by a computer. If you think that this is intentional, you can safely ignore this warning. Use the Escape button to reveal them.

<?xml version="1.0" encoding="UTF-8"?>
<!DOCTYPE html
PUBLIC "-//W3C//DTD XHTML 1.0 Transitional//EN" "http://www.w3.org/TR/xhtml1/DTD/xhtml1-transitional.dtd">
<html lang="en-us" xml:lang="en-us">
<head>
<meta http-equiv="Content-Type" content="text/html; charset=utf-8" />
<meta name="security" content="public" />
<meta name="Robots" content="index,follow" />
<meta http-equiv="PICS-Label" content='(PICS-1.1 "http://www.icra.org/ratingsv02.html" l gen true r (cz 1 lz 1 nz 1 oz 1 vz 1) "http://www.rsac.org/ratingsv01.html" l gen true r (n 0 s 0 v 0 l 0) "http://www.classify.org/safesurf/" l gen true r (SS~~000 1))' />
<meta name="DC.Type" content="concept" />
<meta name="DC.Title" content="Plan to convert the expansion unit" />
<meta name="abstract" content="An expansion unit conversion causes the following changes to the server resources." />
<meta name="description" content="An expansion unit conversion causes the following changes to the server resources." />
<meta name="DC.Relation" scheme="URI" content="rzamdexpanupgradelpar.htm" />
<meta name="DC.Relation" scheme="URI" content="rzamdexpanupgradecable.htm" />
<meta name="DC.Relation" scheme="URI" content="rzamdexpanupgradelpar.htm" />
<meta name="DC.Relation" scheme="URI" content="rzamdexpanupgradecable.htm" />
<meta name="DC.Relation" scheme="URI" content="http://www-1.ibm.com/servers/eserver/iseries/lpar/systemdesign.htm" />
<meta name="DC.Relation" scheme="URI" content="../rzaiu/rzaiurzaiu2tv.htm" />
<meta name="DC.Relation" scheme="URI" content="rzamdprepexpanupgradelpar.htm" />
<meta name="DC.Relation" scheme="URI" content="rzamdtroubles.htm" />
<meta name="copyright" content="(C) Copyright IBM Corporation 1998, 2006" />
<meta name="DC.Rights.Owner" content="(C) Copyright IBM Corporation 1998, 2006" />
<meta name="DC.Format" content="XHTML" />
<meta name="DC.Identifier" content="rzamdplanexpanupgradelpar" />
<meta name="DC.Language" content="en-us" />
<!-- All rights reserved. Licensed Materials Property of IBM -->
<!-- US Government Users Restricted Rights -->
<!-- Use, duplication or disclosure restricted by -->
<!-- GSA ADP Schedule Contract with IBM Corp. -->
<link rel="stylesheet" type="text/css" href="./ibmdita.css" />
<link rel="stylesheet" type="text/css" href="./ic.css" />
<title>Plan to convert the expansion unit</title>
</head>
<body id="rzamdplanexpanupgradelpar"><a name="rzamdplanexpanupgradelpar"><!-- --></a>
<!-- Java sync-link --><script language="Javascript" src="../rzahg/synch.js" type="text/javascript"></script>
<h1 class="topictitle1">Plan to convert the expansion unit</h1>
<div><p>An expansion unit conversion causes the following changes to the
server resources.</p>
<p></p>
<ul><li>The converted expansion units report in to the system with new bus numbers.
The new bus numbers are assigned to the primary partition by default and need
to be assigned to the correct partition before the partition can be powered
on. <div class="note"><span class="notetitle">Note:</span> A 5065 expansion unit contains only one bus. After the conversion,
the 5074 expansion unit has two buses reporting in to the system. A 5066 expansion
unit contains two buses. After the conversion, four buses report in to the
system. The combined function I/O processors in the 5065 or 5066 expansion
units are replaced with new combined function I/O processors and these are
positioned as planned with the LPAR Validation Tool (LVT). Significant I/O
rearrangement may occur with this conversion.</div>
</li>
<li>Nonconverted 5065 and older SPD-based expansion units may have bus numbering
changes if the converted expansion unit is removed. Read the SPD cabling information
to determine if any SPD-based expansion units remaining in the configuration
after the conversion obtain a new bus number.</li>
<li>Some new resource names may be created. The new resource names need to
be reassigned or renamed as appropriate.</li>
</ul>
<p><em>Before you begin:</em> Before you start the expansion unit conversion
or resource name planning, you need to have the following required items:</p>
<ul><li><strong>Valid output from the Logical Partition Validation Tool (LVT).</strong> <p>Use
the LVT tool with your IBM<sup>®</sup> marketing representative or business partner during
the order process. Print the LVT output before beginning the expansion unit
conversion procedures.</p>
</li>
<li><strong>A current backup of the data on all partitions of the server.</strong> <p>Use
the GO SAVE option 21 procedure to back up all partitions of the server. This
is vital for recovery should you experience errors during the expansion unit
conversion.</p>
</li>
</ul>
<p>The expansion unit conversion procedures help determine the partition to
which the new bus numbers should be assigned and how to handle resource names.
These procedures assume a familiarity with the iSeries™ server and a high level
of experience with logical partitions.</p>
</div>
<div>
<ul class="ullinks">
<li class="ulchildlink"><strong><a href="rzamdexpanupgradecable.htm">SPD cabling</a></strong><br />
During a model upgrade or an expansion unit conversion of a partitioned system (moving a partition from one server to another or changing an expansion unit from a 5065 to a 5074), an SPD bus may be removed.</li>
</ul>
<div class="familylinks">
<div class="parentlink"><strong>Parent topic:</strong> <a href="rzamdexpanupgradelpar.htm" title="When performing any of the following expansion unit conversions in a partitioned environment, it is essential that detailed planning is performed before starting the expansion unit conversion.">Convert expansion units for a partitioned server</a></div>
</div>
<div class="relconcepts"><strong>Related concepts</strong><br />
<div><a href="rzamdtroubles.htm" title="Find information about some of the problems that you may run into when upgrading your server.">Troubleshoot the upgrade</a></div>
</div>
<div class="reltasks"><strong>Related tasks</strong><br />
<div><a href="rzamdexpanupgradelpar.htm" title="When performing any of the following expansion unit conversions in a partitioned environment, it is essential that detailed planning is performed before starting the expansion unit conversion.">Convert expansion units for a partitioned server</a></div>
<div><a href="rzamdexpanupgradecable.htm" title="During a model upgrade or an expansion unit conversion of a partitioned system (moving a partition from one server to another or changing an expansion unit from a 5065 to a 5074), an SPD bus may be removed.">SPD cabling</a></div>
<div><a href="http://www-1.ibm.com/servers/eserver/iseries/lpar/systemdesign.htm" target="_blank">LVT tool</a></div>
<div><a href="../rzaiu/rzaiurzaiu2tv.htm">GO SAVE option 21</a></div>
<div><a href="rzamdprepexpanupgradelpar.htm" title="Describes how to prepare for the expansion unit conversion.">Prepare to convert the expansion unit</a></div>
</div>
</div>
</body>
</html>