<meta name="DC.Type" content="task" />
<meta name="DC.Title" content="Place the system in restricted state" />
<meta name="abstract" content="If all of the subsystems, including the controlling subsystem are ended, the system goes into a restricted condition. You can place the system in a restricted condition by using one of two commands from an interactive workstation." />
<meta name="description" content="If all of the subsystems, including the controlling subsystem are ended, the system goes into a restricted condition. You can place the system in a restricted condition by using one of two commands from an interactive workstation." />
<meta name="DC.Relation" scheme="URI" content="rzaksmanagesbs1.htm" />
<meta name="DC.Relation" scheme="URI" content="rzakscontrollingsbs.htm" />
<meta name="DC.Relation" scheme="URI" content="../experience/wmrstateabstract53.htm" />
<meta name="DC.Relation" scheme="URI" content="../experience/wmrstateabstract53.htm" />
<meta name="copyright" content="(C) Copyright IBM Corporation 2004-2006" />
<meta name="DC.Rights.Owner" content="(C) Copyright IBM Corporation 2004-2006" />
<meta name="DC.Format" content="XHTML" />
<meta name="DC.Identifier" content="rzaksmakerestrictedstate" />
<meta name="DC.Language" content="en-us" />
<!-- All rights reserved. Licensed Materials Property of IBM -->
<!-- US Government Users Restricted Rights -->
<!-- Use, duplication or disclosure restricted by -->
<!-- GSA ADP Schedule Contract with IBM Corp. -->
<link rel="stylesheet" type="text/css" href="./ibmdita.css" />
<link rel="stylesheet" type="text/css" href="./ic.css" />
<title>Place the system in restricted state</title>
</head>
<body id="rzaksmakerestrictedstate"><a name="rzaksmakerestrictedstate"><!-- --></a>
<!-- Java sync-link --><script language="Javascript" src="../rzahg/synch.js" type="text/javascript"></script>
<h1 class="topictitle1">Place the system in restricted state</h1>
<div><p>If all of the subsystems, including the controlling subsystem are
ended, the system goes into a restricted condition. You can place the system
in a restricted condition by using one of two commands from an interactive
workstation.</p>
<div class="section"><p><strong>Command</strong>: End Subsystem with the<span class="parmname"> *ALL</span> parameter <span class="cmdname">(ENDSBS
SBS(*ALL))</span></p>
<p><strong>Command:</strong> End System (<span class="cmdname">ENDSYS</span>)</p>
<div class="important"><span class="importanttitle">Important:</span> The <span class="cmdname">ENDSBS</span> or <span class="cmdname">ENDSYS</span> command
should be issued from an interactive job in the controlling subsystem, and
only from a workstation whose entry in the controlling subsystem description
specifies AT(*SIGNON). The interactive job from which the command was issued
remains active when the controlling subsystem goes into a restricted condition.
If the job issuing the command is one of two jobs that are active at the workstation
(using the System Request key or the <span class="cmdname">TFRSECJOB</span> command),
neither of the jobs is forced to end. However, the controlling subsystem does
not end for the restricted condition until you end one of the jobs. Suspending
group jobs also prevents the controlling subsystem from ending (until the
group jobs are ended).<p>When the system is in the restricted condition, most
of the activity on the system has ended, and only one workstation is active.
The system must be in this condition for commands such as Save System (<span class="cmdname">SAVSYS</span>)
or Reclaim Storage (<span class="cmdname">RCLSTG</span>) to run. </p>
<p>Some programs
for diagnosing equipment problems also require the system to be in a restricted
condition. To end the restricted condition you must start the controlling
subsystem again.</p>
</div>
</div>
</div>
<div>
<div class="familylinks">
<div class="parentlink"><strong>Parent topic:</strong> <a href="rzaksmanagesbs1.htm" title="Because jobs run in subsystems, you might need to monitor subsystem activity for potential problems that can affect a job's ability to run.">Manage subsystems</a></div>
</div>
<div class="relconcepts"><strong>Related concepts</strong><br />
<div><a href="rzakscontrollingsbs.htm" title="The controlling subsystem is the interactive subsystem that starts automatically when the system starts, and it is the subsystem through which the system operator controls the system via the system console. It is identified in the Controlling subsystem/library (QCTLSBSD) system value.">The controlling subsystem</a></div>
</div>
<div class="relinfo"><strong>Related information</strong><br />
<div><a href="../experience/wmrstateabstract53.htm">Experience Report: Restricted State</a></div>
</div>
</div>
</body>
</html>