<meta name="DC.Title" content="Change the console from a twinaxial console to an Operations Console in a non-partitioned or primary partitioned server" />
|
|
<meta name="abstract" content="To change from twinaxial to Operations Console, you must perform these steps on the server using the existing console." />
|
|
<meta name="description" content="To change from twinaxial to Operations Console, you must perform these steps on the server using the existing console." />
|
|
<meta name="DC.Relation" scheme="URI" content="rzajrmigratingtwinax.htm" />
|
|
<meta name="DC.Relation" scheme="URI" content="rzajrhardwarereq.htm" />
|
|
<meta name="copyright" content="(C) Copyright IBM Corporation 2000, 2006" />
|
|
<meta name="DC.Rights.Owner" content="(C) Copyright IBM Corporation 2000, 2006" />
|
|
<meta name="DC.Format" content="XHTML" />
|
|
<meta name="DC.Identifier" content="migratingserver3" />
|
|
<meta name="DC.Language" content="en-us" />
|
|
<!-- All rights reserved. Licensed Materials Property of IBM -->
|
|
<!-- US Government Users Restricted Rights -->
|
|
<!-- Use, duplication or disclosure restricted by -->
|
|
<!-- GSA ADP Schedule Contract with IBM Corp. -->
|
|
<link rel="stylesheet" type="text/css" href="./ibmdita.css" />
|
|
<link rel="stylesheet" type="text/css" href="./ic.css" />
|
|
<title>Change the console from a twinaxial console to an Operations Console
|
|
in a non-partitioned or primary partitioned server</title>
|
|
</head>
|
|
<body id="migratingserver3"><a name="migratingserver3"><!-- --></a>
|
|
<!-- Java sync-link --><script language="Javascript" src="../rzahg/synch.js" type="text/javascript"></script>
|
|
<h1 class="topictitle1">Change the console from a twinaxial console to an Operations Console
|
|
in a non-partitioned or primary partitioned server</h1>
|
|
<div><p>To change from twinaxial to Operations Console, you must perform
|
|
these steps on the server using the existing console.</p>
|
|
<ol><li><span>Access <a href="../rzamh/rzamhaccess.htm">Dedicated
|
|
Service Tools (DST) or System Service Tools (SST)</a>. You must unlock
|
|
the SST option "Service tools device IDs" before it is usable.</span></li>
|
|
<li><span>Select <span class="uicontrol">Work with DST environment</span>.</span></li>
|
|
<li><span>Select <span class="uicontrol">System Devices</span> (skip this step if
|
|
using SST).</span></li>
|
|
<li><span>Select <span class="uicontrol">Select Console</span>.</span></li>
|
|
<li><span>Select the new console type.</span><ul><li>If you selected an Operations Console (LAN), do the following:</li>
|
|
</ul>
|
|
<ol type="a"><li class="substepexpand"><span>The Verify Operations Console Adapters window appears. This
|
|
is the resource found by the system to be used for your LAN connection.</span> If you receive a message stating that the LAN adapter was not found,
|
|
you need to satisfy the hardware requirements
|
|
for Operations Console.</li>
|
|
<li class="substepexpand"><span>Press <span class="uicontrol">F11</span> to configure the adapter.</span></li>
|
|
<li class="substepexpand"><span>Enter the appropriate network data.</span></li>
|
|
<li class="substepexpand"><span>Press <span class="uicontrol">F7</span> to store the data.</span></li>
|
|
<li class="substepexpand"><span>Press <span class="uicontrol">F14</span> to activate the adapter for
|
|
use by Operations Console.</span></li>
|
|
</ol>
|
|
<ul><li>If you selected an Operations Console (direct), continue with step
|
|
6.</li>
|
|
</ul>
|
|
</li>
|
|
<li><span>Press <span class="uicontrol">F3</span> until you return to the DST main
|
|
menu.</span></li>
|
|
</ol>
|
|
<div class="section"> <p>The system is now configured for use by your intended console
|
|
type. </p>
|
|
<p>If you do not plan to use the twinaxial device as a backup console
|
|
do not remove it or its adapter at this time. You may need it to debug a problem. </p>
|
|
<p>The
|
|
iSeries system value QAUTOCFG must be set to <span class="uicontrol">ON</span>. Use
|
|
one of the following to verify or set this system value on the iSeries server:</p>
|
|
<ul><li>Use the <span class="cmdname">WRKSYSVAL QAUTOCFG</span> command.</li>
|
|
<li>During a manual IPL, in the IPL Options window, select <strong>Y</strong> for <span class="uicontrol">Set
|
|
major system options.</span> Then, for <span class="uicontrol">Enable automatic configuration</span>,
|
|
select <span class="uicontrol">Y</span>.</li>
|
|
</ul>
|
|
<p>Continue with <a href="rzajrmigratepc2.htm#migratepc2">Configure
|
|
the PC</a>.</p>
|
|
</div>
|
|
</div>
|
|
<div>
|
|
<div class="familylinks">
|
|
<div class="parentlink"><strong>Parent topic:</strong> <a href="rzajrmigratingtwinax.htm" title="To change from a twinaxial console to Operations Console, you a set of steps on both the PC and the server.">Change from a twinaxial console to Operations Console</a></div>
|
|
</div>
|
|
<div class="relref"><strong>Related reference</strong><br />
|
|
<div><a href="rzajrhardwarereq.htm" title="You need to meet the following PC and iSeries hardware requirements for an Operations Console configuration.">Meet Operations Console hardware requirements</a></div>
|
|
</div>
|
|
</div>
|
|
</body>
|
|
</html> |