<meta name="DC.Title" content="cwbCO_SetPortLookupMode" />
|
|
<meta name="DC.Relation" scheme="URI" content="rzaikcommapilist4.htm" />
|
|
<meta name="copyright" content="(C) Copyright IBM Corporation 1999, 2006" />
|
|
<meta name="DC.Rights.Owner" content="(C) Copyright IBM Corporation 1999, 2006" />
|
|
<meta name="DC.Format" content="XHTML" />
|
|
<meta name="DC.Identifier" content="cwbco_setportlookupmode" />
|
|
<meta name="DC.Language" content="en-us" />
|
|
<!-- All rights reserved. Licensed Materials Property of IBM -->
|
|
<!-- US Government Users Restricted Rights -->
|
|
<!-- Use, duplication or disclosure restricted by -->
|
|
<!-- GSA ADP Schedule Contract with IBM Corp. -->
|
|
<link rel="stylesheet" type="text/css" href="./ibmdita.css" />
|
|
<link rel="stylesheet" type="text/css" href="./ic.css" />
|
|
<title>cwbCO_SetPortLookupMode</title>
|
|
</head>
|
|
<body id="cwbco_setportlookupmode"><a name="cwbco_setportlookupmode"><!-- --></a>
|
|
<!-- Java sync-link --><script language="Javascript" src="../rzahg/synch.js" type="text/javascript"></script>
|
|
<h1 class="topictitle1"><span class="apiname">cwbCO_SetPortLookupMode</span></h1>
|
|
<div><div class="section"><h4 class="sectiontitle">Purpose</h4><p>This function sets, for the specified system
|
|
object, how a host server port lookup will be done.</p>
|
|
</div>
|
|
<div class="section"><h4 class="sectiontitle">Syntax</h4><pre>
|
|
UINT CWB_ENTRY cwbCO_SetPortLookupMode(
|
|
cwbCO_SysHandle system,
|
|
cwbCO_PortLookupMode mode );</pre>
|
|
</div>
|
|
<div class="section"><h4 class="sectiontitle">Parameters</h4><dl><dt class="dlterm">cwbCO_SysHandle system - input</dt>
|
|
<dd>Handle that previously was returned by <span class="apiname">cwbCO_CreateSystem</span> or <span class="apiname">cwbCO_CreateSystemLike</span>.
|
|
It identifies the iSeries™ system.</dd>
|
|
<dt class="dlterm">cwbCO_PortLookupMode mode - input</dt>
|
|
<dd>Specifies port lookup method. Possible values are: <dl><dt class="dlterm">CWBCO_PORT_LOOKUP_SERVER</dt>
|
|
<dd>Lookup of a host server port will be done by contacting the host (iSeries)
|
|
server mapper each time the connection of a service is to be made when one
|
|
does not yet exist. The server mapper returns the port number that is then
|
|
used to connect to the desired service on the iSeries system.</dd>
|
|
<dt class="dlterm">CWBCO_PORT_LOOKUP_LOCAL</dt>
|
|
<dd>Lookup of a host server port will be done by lookup in the SERVICES file
|
|
on the PC itself.</dd>
|
|
<dt class="dlterm">CWBCO_PORT_LOOKUP_STANDARD</dt>
|
|
<dd>The "standard" port—that set by default for a given host server and in
|
|
use if no one has changed the services table on the iSeries system for that service—will
|
|
be used to connect to the desired service.</dd>
|
|
</dl>
|
|
<p>The latter two modes eliminate the iSeries server mapper connection and
|
|
its associated delay, network traffic, and load on the iSeries system.</p>
|
|
</dd>
|
|
</dl>
|
|
</div>
|
|
<div class="section"><h4 class="sectiontitle">Return Codes</h4><p>The following list shows common return
|
|
values:</p>
|
|
<dl><dt class="dlterm">CWB_OK</dt>
|
|
<dd>Successful completion.</dd>
|
|
<dt class="dlterm">CWB_INVALID_API_HANDLE</dt>
|
|
<dd>Invalid system handle.</dd>
|
|
<dt class="dlterm">CWB_INVALID_PARAMETER</dt>
|
|
<dd>The mode parameter is an invalid value.</dd>
|
|
<dt class="dlterm">CWB_RESTRICTED_BY_POLICY</dt>
|
|
<dd>A policy exists that prohibits the user from changing this value.</dd>
|
|
<dt class="dlterm">CWB_INV_AFTER_SIGNON</dt>
|
|
<dd>Signon has successfully occurred by using the specified system object,
|
|
so this setting no longer may be changed.</dd>
|
|
</dl>
|
|
</div>
|
|
<div class="section"><h4 class="sectiontitle">Usage</h4><p>This API cannot be used after a successful
|
|
signon has occurred for the specified system object. A signon has occurred
|
|
if either <span class="apiname">cwbCO_Signon</span> or <span class="apiname">cwbCO_Connect</span> has
|
|
been called successfully for this system object.</p>
|
|
<p>Use CWBCO_PORT_LOOKUP_SERVER
|
|
to be most certain of the accuracy of the port number for a service; however,
|
|
this requires an extra connection to the server mapper on the iSeries system
|
|
every time a new connection to a service is to be made.</p>
|
|
<p>Use CWBCO_PORT_LOOKUP_STANDARD
|
|
to achieve the best performance, although if the system administrator has
|
|
changed the ports of any iSeries Access host service in the service table
|
|
on that iSeries system,
|
|
this mode will not work.</p>
|
|
<p>Use CWBCO_PORT_LOOKUP_LOCAL for best performance
|
|
when the port for a iSeries Access host service has been changed on the iSeries system
|
|
represented by the system object. For this to work, entries for each host
|
|
service port must be added to a file on the PC named SERVICES. Each such entry
|
|
must contain first the standard name of the host service (for example, "as-rmtcmd"
|
|
without the quotes) followed by spaces and the port number for that service.
|
|
The SERVICES file is located in a subdirectory under the Windows<sup>®</sup> install
|
|
directory called <span class="uicontrol">system32\drivers\etc</span>.</p>
|
|
</div>
|
|
</div>
|
|
<div>
|
|
<div class="familylinks">
|
|
<div class="parentlink"><strong>Parent topic:</strong> <a href="rzaikcommapilist4.htm" title="Use the APIs to get and set other system object attributes, or determine if the attributes are restricted by policies.">Communications and security: Get and set attribute APIs</a></div>
|
|
</div>
|
|
</div>
|
|
</body>
|
|
</html> |