ibm-information-center/dist/eclipse/plugins/i5OS.ic.rzahj_5.4.0.1/rzahjmn4.htm

64 lines
3.2 KiB
HTML

<?xml version="1.0" encoding="utf-8"?>
<!DOCTYPE html PUBLIC "-//W3C//DTD XHTML 1.0 Transitional//EN"
"http://www.w3.org/TR/xhtml1/DTD/xhtml1-transitional.dtd">
<html xmlns="http://www.w3.org/1999/xhtml" lang="en-US" xml:lang="en-us">
<head>
<meta http-equiv="Content-Type" content="text/html; charset=utf-8" />
<meta name="dc.language" scheme="rfc1766" content="en-us" />
<!-- All rights reserved. Licensed Materials Property of IBM -->
<!-- US Government Users Restricted Rights -->
<!-- Use, duplication or disclosure restricted by -->
<!-- GSA ADP Schedule Contract with IBM Corp. -->
<meta name="dc.date" scheme="iso8601" content="2005-10-03" />
<meta name="copyright" content="(C) Copyright IBM Corporation 1998, 2006" />
<meta name="security" content="public" />
<meta name="Robots" content="index,follow"/>
<meta http-equiv="PICS-Label" content='(PICS-1.1 "http://www.icra.org/ratingsv02.html" l gen true r (cz 1 lz 1 nz 1 oz 1 vz 1) "http://www.rsac.org/ratingsv01.html" l gen true r (n 0 s 0 v 0 l 0) "http://www.classify.org/safesurf/" l gen true r (SS~~000 1))' />
<title>Create controller description A (Minneapolis to Chicago)</title>
<link rel="stylesheet" type="text/css" href="ibmidwb.css" />
<link rel="stylesheet" type="text/css" href="ic.css" />
</head>
<body>
<a id="Top_Of_Page" name="Top_Of_Page"></a><!-- Java sync-link -->
<script language = "Javascript" src = "../rzahg/synch.js" type="text/javascript"></script>
<a name="mn4"></a>
<h5 id="mn4">Create controller description A (Minneapolis to Chicago)</h5>
<p>Because this is an APPN environment (iSeries system to iSeries system), the controller
is an APPC controller, and the CRTCTLAPPC command defines the attributes of
the controller. The example command defines the following attributes: </p>
<dl class="parml">
<dt class="bold">CTLD(CHICAGOL)</dt>
<dd>The name assigned to the controller description is CHICAGOL.
</dd>
<dt class="bold">LINKTYPE(*SDLC)</dt>
<dd>Because this controller is attached through an SDLC communications line,
the value specified is *SDLC. This value must correspond to the type of line
that is defined by a create line description command.
</dd>
<dt class="bold">LINE(CHICAGOL)</dt>
<dd>The name of the line description to which this controller is attached
is CHICAGOL. This value must match a name that is specified by the LIND parameter
in a line description.
</dd>
<dt class="bold">RMTNETID(APPN)</dt>
<dd>The name of the network in which the remote system resides is APPN.
</dd>
<dt class="bold">RMTCPNAME(CHICAGO)</dt>
<dd>The remote control-point name is CHICAGO. The name specified here must
match the name that is specified at the remote system for the local control-point
name. In the example, the LCLCPNAME parameter on the Change Network Attributes
(CHGNETA) command specifies the name at the remote system (CHICAGO).
</dd>
<dt class="bold">STNADR(01)</dt>
<dd>The address assigned to the remote controller is hex 01.
</dd>
<dt class="bold">NODETYPE(*NETNODE)</dt>
<dd>The remote system (CHICAGO) is an APPN network node.
</dd>
</dl>