ibm-information-center/dist/eclipse/plugins/i5OS.ic.rzahj_5.4.0.1/rzahjccdescmnch1.htm

66 lines
3.3 KiB
HTML

<?xml version="1.0" encoding="utf-8"?>
<!DOCTYPE html PUBLIC "-//W3C//DTD XHTML 1.0 Transitional//EN"
"http://www.w3.org/TR/xhtml1/DTD/xhtml1-transitional.dtd">
<html xmlns="http://www.w3.org/1999/xhtml" lang="en-US" xml:lang="en-us">
<head>
<meta http-equiv="Content-Type" content="text/html; charset=utf-8" />
<meta name="dc.language" scheme="rfc1766" content="en-us" />
<!-- All rights reserved. Licensed Materials Property of IBM -->
<!-- US Government Users Restricted Rights -->
<!-- Use, duplication or disclosure restricted by -->
<!-- GSA ADP Schedule Contract with IBM Corp. -->
<meta name="dc.date" scheme="iso8601" content="2005-10-03" />
<meta name="copyright" content="(C) Copyright IBM Corporation 1998, 2006" />
<meta name="security" content="public" />
<meta name="Robots" content="index,follow"/>
<meta http-equiv="PICS-Label" content='(PICS-1.1 "http://www.icra.org/ratingsv02.html" l gen true r (cz 1 lz 1 nz 1 oz 1 vz 1) "http://www.rsac.org/ratingsv01.html" l gen true r (n 0 s 0 v 0 l 0) "http://www.classify.org/safesurf/" l gen true r (SS~~000 1))' />
<title>Create the controller description (Minneapolis to Chicago, nonswitched)</title>
<link rel="stylesheet" type="text/css" href="ibmidwb.css" />
<link rel="stylesheet" type="text/css" href="ic.css" />
</head>
<body>
<a id="Top_Of_Page" name="Top_Of_Page"></a><!-- Java sync-link -->
<script language = "Javascript" src = "../rzahg/synch.js" type="text/javascript"></script>
<a name="ccdescmnch1"></a>
<h5 id="ccdescmnch1">Create the controller description (Minneapolis to Chicago, nonswitched)</h5>
<p>Because this is an APPN environment (iSeries system to iSeries system), the controller
is an APPC controller and the CRTCTLAPPC command is used to define the attributes
of the controller. The example command defines the following attributes: </p>
<dl class="parml">
<dt class="bold">CTLD(CHICAGOL)</dt>
<dd>The name assigned to the controller description is CHICAGOL.
</dd>
<dt class="bold">LINKTYPE(*SDLC)</dt>
<dd>Because this controller is attached through an SDLC communications line,
the value specified is *SDLC. This value must correspond to the type of line
being used as defined by a create line description command.
</dd>
<dt class="bold">LINE(CHICAGOL)</dt>
<dd>Specifies the name (CHICAGOL) of the line description to which this
controller is attached. This value must match a name that is specified by
the LIND parameter in a line description.
</dd>
<dt class="bold">RMTNETID(APPN)</dt>
<dd>The name of the network in which the remote control point resides is
APPN.
</dd>
<dt class="bold">RMTCPNAME(CHICAGO)</dt>
<dd>Specifies that the remote control-point name is CHICAGO. The name specified
here must match the name that is specified at the remote system for the local
control-point name. In the example, the name is specified at the remote system
(CHICAGO) by the LCLCPNAME parameter on the Change Network Attributes (CHGNETA)
command.
</dd>
<dt class="bold">STNADR(01)</dt>
<dd>The address assigned to the remote controller is hex 01.
</dd>
<dt class="bold">NODETYPE(*NETNODE)</dt>
<dd>Specifies that the remote location (CHICAGO) is an APPN networking node.
</dd>