114 lines
7.3 KiB
HTML
114 lines
7.3 KiB
HTML
<?xml version="1.0" encoding="UTF-8"?>
|
|
<!DOCTYPE html
|
|
PUBLIC "-//W3C//DTD XHTML 1.0 Transitional//EN" "http://www.w3.org/TR/xhtml1/DTD/xhtml1-transitional.dtd">
|
|
<html lang="en-us" xml:lang="en-us">
|
|
<head>
|
|
<meta http-equiv="Content-Type" content="text/html; charset=utf-8" />
|
|
<meta name="security" content="public" />
|
|
<meta name="Robots" content="index,follow" />
|
|
<meta http-equiv="PICS-Label" content='(PICS-1.1 "http://www.icra.org/ratingsv02.html" l gen true r (cz 1 lz 1 nz 1 oz 1 vz 1) "http://www.rsac.org/ratingsv01.html" l gen true r (n 0 s 0 v 0 l 0) "http://www.classify.org/safesurf/" l gen true r (SS~~000 1))' />
|
|
<meta name="DC.Type" content="reference" />
|
|
<meta name="DC.Title" content="Copy screen" />
|
|
<meta name="abstract" content="The Start Copy Screen (STRCPYSCN) command allows you to be signed on to your workstation and see the same displays being viewed by someone else at another workstation." />
|
|
<meta name="description" content="The Start Copy Screen (STRCPYSCN) command allows you to be signed on to your workstation and see the same displays being viewed by someone else at another workstation." />
|
|
<meta name="DC.subject" content="problem handling, copying displays, display, copying, command, CL, STRCPYSCRN (Start Copy Screen), Start Copy Screen (STRCPYSCRN), command, STRCPYSCRN (Start Copy Screen), using display station pass-through, STRPASTHR (Start Pass-Through), Start Pass-Through (STRPASTHR), command, CL, STRPASTHR (Start Pass-Through), pass-through, starting" />
|
|
<meta name="keywords" content="problem handling, copying displays, display, copying, command, CL, STRCPYSCRN (Start Copy Screen), Start Copy Screen (STRCPYSCRN), command, STRCPYSCRN (Start Copy Screen), using display station pass-through, STRPASTHR (Start Pass-Through), Start Pass-Through (STRPASTHR), command, CL, STRPASTHR (Start Pass-Through), pass-through, starting" />
|
|
<meta name="DC.Relation" scheme="URI" content="rbal1wwu.htm" />
|
|
<meta name="DC.Relation" scheme="URI" content="../cl/strpasthr.htm" />
|
|
<meta name="copyright" content="(C) Copyright IBM Corporation 1998, 2006" />
|
|
<meta name="DC.Rights.Owner" content="(C) Copyright IBM Corporation 1998, 2006" />
|
|
<meta name="DC.Format" content="XHTML" />
|
|
<meta name="DC.Identifier" content="rbal1sci" />
|
|
<meta name="DC.Language" content="en-us" />
|
|
<!-- All rights reserved. Licensed Materials Property of IBM -->
|
|
<!-- US Government Users Restricted Rights -->
|
|
<!-- Use, duplication or disclosure restricted by -->
|
|
<!-- GSA ADP Schedule Contract with IBM Corp. -->
|
|
<link rel="stylesheet" type="text/css" href="./ibmdita.css" />
|
|
<link rel="stylesheet" type="text/css" href="./ic.css" />
|
|
<title>Copy screen</title>
|
|
</head>
|
|
<body id="rbal1sci"><a name="rbal1sci"><!-- --></a>
|
|
<!-- Java sync-link --><script language="Javascript" src="../rzahg/synch.js" type="text/javascript"></script>
|
|
<h1 class="topictitle1">Copy screen</h1>
|
|
<div><p>The <span class="cmdname">Start Copy Screen (STRCPYSCN)</span> command allows
|
|
you to be signed on to your workstation and see the same displays being viewed
|
|
by someone else at another workstation.</p>
|
|
<div class="section"><p>You must be signed on to the same <span class="keyword">iSeries™ server</span> as
|
|
the user. If that user is on a remote server, you can use display station
|
|
pass-through to sign on that server and then enter the (<span class="cmdname">STRCPYSCN</span>)
|
|
command to see the other displays. Screen images can be copied to a database
|
|
file at the same time they are copied to another workstation or when another
|
|
workstation cannot be used. This allows you to process this data later and
|
|
prepares an audit trail for the operations that occur during a problem situation.</p>
|
|
</div>
|
|
<div class="section"><p>To copy the display image to another display station, the following
|
|
requirements must be met: </p>
|
|
<ul><li>Both displays are defined to the server</li>
|
|
<li>Both displays are color or both are monochrome, but not one color and
|
|
the other monochrome</li>
|
|
<li>Both displays have the same number of character positions horizontally
|
|
and vertically</li>
|
|
</ul>
|
|
</div>
|
|
<div class="section"><p>If you type your own display station ID as the sending device,
|
|
the receiving display station must have the sign on display shown when you
|
|
start copying screen images. Graphics are copied as blanks.</p>
|
|
</div>
|
|
<div class="section"><p>If not already signed on to the same server, use the following
|
|
process to see the displays that another user sees on a remote server: </p>
|
|
</div>
|
|
<div class="section"><div class="p"> <ol><li>Enter the <span class="cmdname">Start Pass-Through (STRPASTHR)</span> command. <pre>STRPASTHR RMTLOCNAME(KC105)</pre>
|
|
</li>
|
|
<li>Log on to the application server (AS).</li>
|
|
<li>Enter the (<span class="cmdname">STRCPYSCN</span>) command. <pre>STRCPYSCN SRCDEV(KC105)
|
|
OUTDEV(*REQUESTER)
|
|
OUTFILE(KCHELP/TEST)</pre>
|
|
<div class="p"> <ul><li>SRCDEV specifies the name of the source device, the display station that
|
|
is sending the display image. To send your display to command to another device,
|
|
enter the *REQUESTER value for this parameter.</li>
|
|
<li>OUTDEV specifies the name of the output device to which the display image
|
|
is sent. In this example, the display image is sent to the display station
|
|
of the person who enters the command (*REQUESTER). You can also name another
|
|
display station, another device (where a third user is viewing), or to no
|
|
other device (*NONE). When the *NONE value is used, specify an output file
|
|
for the display images.</li>
|
|
<li>OUTFILE specifies the name of the output file that will contain an image
|
|
of all the displays viewed while the command is active.</li>
|
|
</ul>
|
|
</div>
|
|
</li>
|
|
<li>An inquiry message is sent to the source device to notify the user of
|
|
that device that the displays will be copied to another device or file. Type
|
|
a <samp class="codeph">g</samp> (Go) to start sending the images to the requesting device.</li>
|
|
</ol>
|
|
</div>
|
|
</div>
|
|
<div class="section"><p>The sending display station's screens are copied to the other
|
|
display station. The image shown at the receiving display station trails the
|
|
sending display station by one screen. If the user at the sending display
|
|
station presses a key that is not active (such as the Home key), both display
|
|
stations will show the same display.</p>
|
|
</div>
|
|
<div class="section"><p>While you are copying screens, the operator of the receiving display
|
|
station cannot do any other work at that display station until the copying
|
|
of screens is ended.</p>
|
|
</div>
|
|
<div class="section"><p>To end the copy screen function from the sending display station,
|
|
enter the <span class="cmdname">End Copy Screen (ENDCPYSCN)</span> command from any
|
|
command line and press the Enter key. </p>
|
|
<pre>ENDCPYSCN</pre>
|
|
<p>The
|
|
display you viewed when you started the copy screen function is shown.</p>
|
|
</div>
|
|
</div>
|
|
<div>
|
|
<div class="familylinks">
|
|
<div class="parentlink"><strong>Parent topic:</strong> <a href="rbal1wwu.htm" title="Investigating a problem usually begins with the user. Users might not be getting the results they expect when running a program or they might get a message indicating a problem. Sometimes the best way to diagnose and solve a problem is to go through the procedure with a user.">Work with distributed relational database users</a></div>
|
|
</div>
|
|
<div class="relinfo"><strong>Related information</strong><br />
|
|
<div><a href="../cl/strpasthr.htm">Start Pass-Through (STRPASTHR) command</a></div>
|
|
</div>
|
|
</div>
|
|
</body>
|
|
</html> |