<!doctype html PUBLIC "-//W3C//DTD HTML 4.01 Transitional//EN">
|
|
<html>
|
|
<head><META http-equiv="Content-Type" content="text/html; charset=utf-8">
|
|
<title>Print Component Report (PRTCPTRPT)</title>
|
|
<link rel="stylesheet" type="text/css" href="../rzahg/ic.css">
|
|
</head>
|
|
<body bgcolor="white">
|
|
<script language="Javascript" src="../rzahg/synch.js" type="text/javascript"></script>
|
|
<a name="PRTCPTRPT.Top_Of_Page"></a>
|
|
<h2>Print Component Report (PRTCPTRPT)</h2>
|
|
<table width="100%">
|
|
<tr>
|
|
<td valign="top" align="left"><b>Where allowed to run: </b>All environments (*ALL)<br>
|
|
<b>Threadsafe: </b>No
|
|
</td>
|
|
<td valign="top" align="right">
|
|
<a href="#PRTCPTRPT.PARAMETERS.TABLE">Parameters</a><br>
|
|
<a href="#PRTCPTRPT.COMMAND.EXAMPLES">Examples</a><br>
|
|
<a href="#PRTCPTRPT.ERROR.MESSAGES">Error messages</a></td>
|
|
</tr>
|
|
</table>
|
|
|
|
<div> <a name="PRTCPTRPT"></a>
|
|
<p>The Print Component Report (PRTCPTRPT) command produces a report that expands on the information given in the System Report. Detailed information regarding the system performance of each component is reported. This detailed report is produced from the performance data collected by Collection Services from the Operations Navigator interface and shows the data by job, user, pool, disk, IOP, local work station, exception, data base journaling, and TCP/IP. The report is written to the printer file QPPTCPTR. Jobs can be selectively included in the report or excluded from the report, based on a variety of job details and interval times.
|
|
</p>
|
|
</div>
|
|
<table width="100%">
|
|
<tr><td align="right"><a href="#PRTCPTRPT.Top_Of_Page">Top</a></td></tr>
|
|
</table>
|
|
<hr size="2" width="100%">
|
|
|
|
<div>
|
|
<h3><a name="PRTCPTRPT.PARAMETERS.TABLE">Parameters</a></h3>
|
|
<table border="1" cellpadding="4" cellspacing="0">
|
|
<!-- col1="10" col2="15" col3="30" col4="10" -->
|
|
<tr>
|
|
<th bgcolor="aqua" valign="bottom" align="left">Keyword</th>
|
|
<th bgcolor="aqua" valign="bottom" align="left">Description</th>
|
|
<th bgcolor="aqua" valign="bottom" align="left">Choices</th>
|
|
<th bgcolor="aqua" valign="bottom" align="left">Notes</th>
|
|
</tr>
|
|
<tr>
|
|
<td valign="top"><a href="#PRTCPTRPT.MBR"><b>MBR</b></a></td>
|
|
<td valign="top">Member</td>
|
|
<td valign="top"><i>Name</i></td>
|
|
<td valign="top">Required, Positional 1</td>
|
|
</tr>
|
|
<tr>
|
|
<td valign="top"><a href="#PRTCPTRPT.TITLE"><b>TITLE</b></a></td>
|
|
<td valign="top">Report title</td>
|
|
<td valign="top"><i>Character value</i>, <b><u>*MBR</u></b></td>
|
|
<td valign="top">Optional, Positional 3</td>
|
|
</tr>
|
|
<tr>
|
|
<td valign="top" rowspan="7"><a href="#PRTCPTRPT.PERIOD"><b>PERIOD</b></a></td>
|
|
<td valign="top">Time period for report</td>
|
|
<td valign="top"><i>Element list</i></td>
|
|
<td valign="top" rowspan="7">Optional</td>
|
|
</tr>
|
|
<tr>
|
|
<td valign="top">Element 1: </td>
|
|
<td valign="top">
|
|
<i>Element list</i></td>
|
|
</tr>
|
|
<tr>
|
|
<td valign="top" style="padding-left:10pt">Element 1: Starting time</td>
|
|
<td valign="top">
|
|
<i>Time</i>, <b><u>*FIRST</u></b>, *SELECT</td>
|
|
</tr>
|
|
<tr>
|
|
<td valign="top" style="padding-left:10pt">Element 2: Starting date</td>
|
|
<td valign="top">
|
|
<i>Date</i>, <b><u>*FIRST</u></b></td>
|
|
</tr>
|
|
<tr>
|
|
<td valign="top">Element 2: </td>
|
|
<td valign="top">
|
|
<i>Element list</i></td>
|
|
</tr>
|
|
<tr>
|
|
<td valign="top" style="padding-left:10pt">Element 1: Ending time</td>
|
|
<td valign="top">
|
|
<i>Time</i>, <b><u>*LAST</u></b></td>
|
|
</tr>
|
|
<tr>
|
|
<td valign="top" style="padding-left:10pt">Element 2: Ending date</td>
|
|
<td valign="top">
|
|
<i>Date</i>, <b><u>*LAST</u></b></td>
|
|
</tr>
|
|
<tr>
|
|
<td valign="top"><a href="#PRTCPTRPT.LIB"><b>LIB</b></a></td>
|
|
<td valign="top">Library</td>
|
|
<td valign="top"><i>Name</i>, <b><u>QPFRDATA</u></b></td>
|
|
<td valign="top">Optional, Positional 2</td>
|
|
</tr>
|
|
<tr>
|
|
<td valign="top"><a href="#PRTCPTRPT.TYPE"><b>TYPE</b></a></td>
|
|
<td valign="top">Type of information</td>
|
|
<td valign="top">Single values: <b><u>*ALL</u></b><br>Other values (up to 12 repetitions): *INTERVAL, *WORKLOAD, *POOL, *DISK, *IOP, *LCLWS, *RMTWS, *EXCEPTION, *DBJRN, *TCPIP, *HTTP, *DOMINO</td>
|
|
<td valign="top">Optional</td>
|
|
</tr>
|
|
<tr>
|
|
<td valign="top"><a href="#PRTCPTRPT.DETAIL"><b>DETAIL</b></a></td>
|
|
<td valign="top">Report detail</td>
|
|
<td valign="top"><b><u>*JOB</u></b>, *THREAD</td>
|
|
<td valign="top">Optional</td>
|
|
</tr>
|
|
<tr>
|
|
<td valign="top" rowspan="7"><a href="#PRTCPTRPT.SLTJOB"><b>SLTJOB</b></a></td>
|
|
<td valign="top">Select jobs</td>
|
|
<td valign="top">Single values: <b><u>*ALL</u></b><br>Other values (up to 50 repetitions): <i>Element list</i></td>
|
|
<td valign="top" rowspan="7">Optional</td>
|
|
</tr>
|
|
<tr>
|
|
<td valign="top">Element 1: Job name</td>
|
|
<td valign="top">
|
|
<i>Qualified job name</i></td>
|
|
</tr>
|
|
<tr>
|
|
<td valign="top" style="padding-left:10pt">Qualifier 1: Job name</td>
|
|
<td valign="top"><i>Generic name, name</i></td>
|
|
</tr><tr>
|
|
<td valign="top" style="padding-left:10pt">Qualifier 2: User</td>
|
|
<td valign="top"><i>Name</i></td>
|
|
</tr><tr>
|
|
<td valign="top" style="padding-left:10pt">Qualifier 3: Number</td>
|
|
<td valign="top">000000-999999</td>
|
|
</tr><tr>
|
|
<td valign="top">Element 2: </td>
|
|
<td valign="top">
|
|
<i>Element list</i></td>
|
|
</tr>
|
|
<tr>
|
|
<td valign="top" style="padding-left:10pt">Element 1: Thread</td>
|
|
<td valign="top">
|
|
<i>Character value</i>, <b><u>*ALL</u></b></td>
|
|
</tr>
|
|
<tr>
|
|
<td valign="top" rowspan="7"><a href="#PRTCPTRPT.OMTJOB"><b>OMTJOB</b></a></td>
|
|
<td valign="top">Omit jobs</td>
|
|
<td valign="top">Single values: <b><u>*NONE</u></b><br>Other values (up to 50 repetitions): <i>Element list</i></td>
|
|
<td valign="top" rowspan="7">Optional</td>
|
|
</tr>
|
|
<tr>
|
|
<td valign="top">Element 1: Job name</td>
|
|
<td valign="top">
|
|
<i>Qualified job name</i></td>
|
|
</tr>
|
|
<tr>
|
|
<td valign="top" style="padding-left:10pt">Qualifier 1: Job name</td>
|
|
<td valign="top"><i>Generic name, name</i></td>
|
|
</tr><tr>
|
|
<td valign="top" style="padding-left:10pt">Qualifier 2: User</td>
|
|
<td valign="top"><i>Name</i></td>
|
|
</tr><tr>
|
|
<td valign="top" style="padding-left:10pt">Qualifier 3: Number</td>
|
|
<td valign="top">000000-999999</td>
|
|
</tr><tr>
|
|
<td valign="top">Element 2: </td>
|
|
<td valign="top">
|
|
<i>Element list</i></td>
|
|
</tr>
|
|
<tr>
|
|
<td valign="top" style="padding-left:10pt">Element 1: Thread</td>
|
|
<td valign="top">
|
|
<i>Character value</i>, <b><u>*ALL</u></b></td>
|
|
</tr>
|
|
<tr>
|
|
<td valign="top"><a href="#PRTCPTRPT.SLTUSRID"><b>SLTUSRID</b></a></td>
|
|
<td valign="top">Select users</td>
|
|
<td valign="top">Single values: <b><u>*ALL</u></b><br>Other values (up to 50 repetitions): <i>Generic name, name</i></td>
|
|
<td valign="top">Optional</td>
|
|
</tr>
|
|
<tr>
|
|
<td valign="top"><a href="#PRTCPTRPT.OMTUSRID"><b>OMTUSRID</b></a></td>
|
|
<td valign="top">Omit users</td>
|
|
<td valign="top">Single values: <b><u>*NONE</u></b><br>Other values (up to 50 repetitions): <i>Generic name, name</i></td>
|
|
<td valign="top">Optional</td>
|
|
</tr>
|
|
<tr>
|
|
<td valign="top"><a href="#PRTCPTRPT.SLTJOBTYPE"><b>SLTJOBTYPE</b></a></td>
|
|
<td valign="top">Select job type</td>
|
|
<td valign="top">Single values: <b><u>*ALL</u></b><br>Other values (up to 15 repetitions): A, B, C, D, E, I, L, M, P, R, S, T, W, X, 3</td>
|
|
<td valign="top">Optional</td>
|
|
</tr>
|
|
<tr>
|
|
<td valign="top"><a href="#PRTCPTRPT.OMTJOBTYPE"><b>OMTJOBTYPE</b></a></td>
|
|
<td valign="top">Omit job type</td>
|
|
<td valign="top">Single values: <b><u>*NONE</u></b><br>Other values (up to 15 repetitions): A, B, C, D, E, I, L, M, P, R, S, T, W, X, 3</td>
|
|
<td valign="top">Optional</td>
|
|
</tr>
|
|
<tr>
|
|
<td valign="top" rowspan="3"><a href="#PRTCPTRPT.SLTRUNPTY"><b>SLTRUNPTY</b></a></td>
|
|
<td valign="top">Select job run priority</td>
|
|
<td valign="top">Single values: <b><u>*ALL</u></b><br>Other values: <i>Element list</i></td>
|
|
<td valign="top" rowspan="3">Optional</td>
|
|
</tr>
|
|
<tr>
|
|
<td valign="top">Element 1: Highest priority</td>
|
|
<td valign="top">
|
|
0-99</td>
|
|
</tr>
|
|
<tr>
|
|
<td valign="top">Element 2: Lowest priority</td>
|
|
<td valign="top">
|
|
0-99</td>
|
|
</tr>
|
|
<tr>
|
|
<td valign="top" rowspan="3"><a href="#PRTCPTRPT.OMTRUNPTY"><b>OMTRUNPTY</b></a></td>
|
|
<td valign="top">Omit job run priority</td>
|
|
<td valign="top">Single values: <b><u>*NONE</u></b><br>Other values: <i>Element list</i></td>
|
|
<td valign="top" rowspan="3">Optional</td>
|
|
</tr>
|
|
<tr>
|
|
<td valign="top">Element 1: Highest priority</td>
|
|
<td valign="top">
|
|
0-99</td>
|
|
</tr>
|
|
<tr>
|
|
<td valign="top">Element 2: Lowest priority</td>
|
|
<td valign="top">
|
|
0-99</td>
|
|
</tr>
|
|
<tr>
|
|
<td valign="top"><a href="#PRTCPTRPT.SLTPOOLS"><b>SLTPOOLS</b></a></td>
|
|
<td valign="top">Select pools</td>
|
|
<td valign="top">Single values: <b><u>*ALL</u></b><br>Other values (up to 64 repetitions): 1-64</td>
|
|
<td valign="top">Optional</td>
|
|
</tr>
|
|
<tr>
|
|
<td valign="top"><a href="#PRTCPTRPT.OMTPOOLS"><b>OMTPOOLS</b></a></td>
|
|
<td valign="top">Omit pools</td>
|
|
<td valign="top">Single values: <b><u>*NONE</u></b><br>Other values (up to 64 repetitions): 1-64</td>
|
|
<td valign="top">Optional</td>
|
|
</tr>
|
|
<tr>
|
|
<td valign="top"><a href="#PRTCPTRPT.SLTSBS"><b>SLTSBS</b></a></td>
|
|
<td valign="top">Select subsystems</td>
|
|
<td valign="top">Single values: <b><u>*ALL</u></b><br>Other values (up to 50 repetitions): <i>Name</i></td>
|
|
<td valign="top">Optional</td>
|
|
</tr>
|
|
<tr>
|
|
<td valign="top"><a href="#PRTCPTRPT.OMTSBS"><b>OMTSBS</b></a></td>
|
|
<td valign="top">Omit subsystems</td>
|
|
<td valign="top">Single values: <b><u>*NONE</u></b><br>Other values (up to 50 repetitions): <i>Name</i></td>
|
|
<td valign="top">Optional</td>
|
|
</tr>
|
|
<tr>
|
|
<td valign="top"><a href="#PRTCPTRPT.SLTLINE"><b>SLTLINE</b></a></td>
|
|
<td valign="top">Select communications lines</td>
|
|
<td valign="top">Single values: <b><u>*ALL</u></b><br>Other values (up to 50 repetitions): <i>Name</i></td>
|
|
<td valign="top">Optional</td>
|
|
</tr>
|
|
<tr>
|
|
<td valign="top"><a href="#PRTCPTRPT.OMTLINE"><b>OMTLINE</b></a></td>
|
|
<td valign="top">Omit communications lines</td>
|
|
<td valign="top">Single values: <b><u>*NONE</u></b><br>Other values (up to 50 repetitions): <i>Name</i></td>
|
|
<td valign="top">Optional</td>
|
|
</tr>
|
|
<tr>
|
|
<td valign="top"><a href="#PRTCPTRPT.SLTCTL"><b>SLTCTL</b></a></td>
|
|
<td valign="top">Select control units</td>
|
|
<td valign="top">Single values: <b><u>*ALL</u></b><br>Other values (up to 50 repetitions): <i>Name</i></td>
|
|
<td valign="top">Optional</td>
|
|
</tr>
|
|
<tr>
|
|
<td valign="top"><a href="#PRTCPTRPT.OMTCTL"><b>OMTCTL</b></a></td>
|
|
<td valign="top">Omit control units</td>
|
|
<td valign="top">Single values: <b><u>*NONE</u></b><br>Other values (up to 50 repetitions): <i>Name</i></td>
|
|
<td valign="top">Optional</td>
|
|
</tr>
|
|
<tr>
|
|
<td valign="top"><a href="#PRTCPTRPT.SLTFCNARA"><b>SLTFCNARA</b></a></td>
|
|
<td valign="top">Select functional areas</td>
|
|
<td valign="top">Single values: <b><u>*ALL</u></b><br>Other values (up to 50 repetitions): <i>Character value</i></td>
|
|
<td valign="top">Optional</td>
|
|
</tr>
|
|
<tr>
|
|
<td valign="top"><a href="#PRTCPTRPT.OMTFCNARA"><b>OMTFCNARA</b></a></td>
|
|
<td valign="top">Omit functional areas</td>
|
|
<td valign="top">Single values: <b><u>*NONE</u></b><br>Other values (up to 50 repetitions): <i>Character value</i></td>
|
|
<td valign="top">Optional</td>
|
|
</tr>
|
|
<tr>
|
|
<td valign="top"><a href="#PRTCPTRPT.JOB"><b>JOB</b></a></td>
|
|
<td valign="top">Job name</td>
|
|
<td valign="top"><i>Name</i>, <b><u>PRTCPTRPT</u></b>, *MBR</td>
|
|
<td valign="top">Optional</td>
|
|
</tr>
|
|
<tr>
|
|
<td valign="top" rowspan="3"><a href="#PRTCPTRPT.JOBD"><b>JOBD</b></a></td>
|
|
<td valign="top">Job description</td>
|
|
<td valign="top">Single values: *NONE<br>Other values: <i>Qualified object name</i></td>
|
|
<td valign="top" rowspan="3">Optional</td>
|
|
</tr>
|
|
<tr>
|
|
<td valign="top">Qualifier 1: Job description</td>
|
|
<td valign="top"><i>Name</i>, <b><u>QPFRJOBD</u></b></td>
|
|
</tr><tr>
|
|
<td valign="top">Qualifier 2: Library</td>
|
|
<td valign="top"><i>Name</i>, <b><u>*LIBL</u></b>, *CURLIB</td>
|
|
</tr></table>
|
|
|
|
<table width="100%">
|
|
<tr><td align="right"><a href="#PRTCPTRPT.Top_Of_Page">Top</a></td></tr>
|
|
</table>
|
|
</div>
|
|
<div> <a name="PRTCPTRPT.MBR"></a>
|
|
<h3>Member (MBR)</h3>
|
|
<p>Specifies the performance data member used. This name should correspond to the member name specified on the TOMBR parameter of the Create Performance Data (CRTPFRDTA) command.
|
|
</p>
|
|
<p>This is a required parameter.
|
|
</p>
|
|
</div>
|
|
<table width="100%">
|
|
<tr><td align="right"><a href="#PRTCPTRPT.Top_Of_Page">Top</a></td></tr>
|
|
</table>
|
|
<div> <a name="PRTCPTRPT.TITLE"></a>
|
|
<h3>Report title (TITLE)</h3>
|
|
<p>Specifies the title for the report that is created.
|
|
</p>
|
|
<dl>
|
|
<dt><b><u>*MBR</u></b></dt>
|
|
<dd>The text of the database member, which contains the performance data, is the report title.
|
|
</dd>
|
|
<dt><b><i>'report-title'</i></b></dt>
|
|
<dd>Specify the title you want on your report with up to 50 characters of text, enclosed in apostrophes.
|
|
</dd>
|
|
</dl>
|
|
</div>
|
|
<table width="100%">
|
|
<tr><td align="right"><a href="#PRTCPTRPT.Top_Of_Page">Top</a></td></tr>
|
|
</table>
|
|
<div> <a name="PRTCPTRPT.PERIOD"></a>
|
|
<h3>Time period for report (PERIOD)</h3>
|
|
<p>Specifies the period of time on which to report. The parameter consists of four elements: a starting time and date, and an ending time and date. Data collected prior to the starting time on the starting date and after the ending time on the ending date is not included in the report.
|
|
</p>
|
|
<p>The symbol *N can be used to designate the default value for any of the four elements.
|
|
</p>
|
|
<p>The possible <b>starting time</b> values are:
|
|
</p>
|
|
<dl>
|
|
<dt><b><u>*FIRST</u></b></dt>
|
|
<dd>Data records starting from the beginning of the first day (00:00:00) of the collection period are included.
|
|
</dd>
|
|
<dt><b>*SELECT</b></dt>
|
|
<dd>An interval selection screen is displayed from which you can select one or more intervals for inclusion. This value is valid only in the interactive environment. If this value is used, the remaining values of this parameter (starting time and date and ending time and date) are ignored.
|
|
</dd>
|
|
<dt><b><i>start-time</i></b></dt>
|
|
<dd>Specify the time of the first data record to include in the report, using the format, <b>hhmm</b> or <b>hhmmss</b>, where <b>hh</b> is the hours, <b>mm</b> is the minutes, and <b>ss</b> is the seconds.
|
|
<p>The time is specified in 24-hour format with or without a time separator:
|
|
</p>
|
|
<ul>
|
|
<li>Without a time separator, specify a string of 4 or 6 digits (hhmm or hhmmss) where hh = hours, mm = minutes, and ss = seconds.
|
|
</li>
|
|
<li>With a time separator, specify a string of 5 or 8 digits where the time separator specified for your job is used to separate the hours, minutes, and seconds. If you enter this command from the command line, the string must be enclosed in apostrophes. If a time separator other than the separator specified for your job is used, this command will fail.
|
|
</li>
|
|
</ul>
|
|
<p>All time and date entries must be 2-digits in length, meaning zeros must be included.
|
|
</p>
|
|
</dd>
|
|
</dl>
|
|
<p>The possible <b>starting date</b> values are:
|
|
</p>
|
|
<dl>
|
|
<dt><b><u>*FIRST</u></b></dt>
|
|
<dd>Data records starting from the first day of the collection period are included in the report.
|
|
</dd>
|
|
<dt><b><i>start-date</i></b></dt>
|
|
<dd>Specify the date of the first data record to include in the report. The date must be entered in the format specified by the system value QDATFMT, and if separators are used, as specified by the system value QDATSEP.
|
|
</dd>
|
|
</dl>
|
|
<p>The possible <b>ending time</b> values are:
|
|
</p>
|
|
<dl>
|
|
<dt><b><u>*LAST</u></b></dt>
|
|
<dd>Data records through the end of the day (23:59:59) are included in the report.
|
|
</dd>
|
|
<dt><b><i>end-time</i></b></dt>
|
|
<dd>Specify the time of the last data record to include in the report. Use the same format used for the starting time.
|
|
</dd>
|
|
</dl>
|
|
<p>The possible <b>ending date</b> values are:
|
|
</p>
|
|
<dl>
|
|
<dt><b><u>*LAST</u></b></dt>
|
|
<dd>Data records through the last day of the collection period are included in the report.
|
|
</dd>
|
|
<dt><b><i>end-date</i></b></dt>
|
|
<dd>Specify the date of the last record to include in the report. The date must be entered in the format specified by the system value QDATFMT, and if separators are used, as specified by the system value QDATSEP.
|
|
</dd>
|
|
</dl>
|
|
</div>
|
|
<table width="100%">
|
|
<tr><td align="right"><a href="#PRTCPTRPT.Top_Of_Page">Top</a></td></tr>
|
|
</table>
|
|
<div> <a name="PRTCPTRPT.LIB"></a>
|
|
<h3>Library (LIB)</h3>
|
|
<p>Specifies the library where the performance data is located.
|
|
</p>
|
|
<dl>
|
|
<dt><b><u>QPFRDATA</u></b></dt>
|
|
<dd>The performance data files are located in the IBM-supplied performance data library, QPFRDATA.
|
|
</dd>
|
|
<dt><b><i>library-name</i></b></dt>
|
|
<dd>Specify the name of the library where the performance database files are located.
|
|
</dd>
|
|
</dl>
|
|
</div>
|
|
<table width="100%">
|
|
<tr><td align="right"><a href="#PRTCPTRPT.Top_Of_Page">Top</a></td></tr>
|
|
</table>
|
|
<div> <a name="PRTCPTRPT.TYPE"></a>
|
|
<h3>Type of information (TYPE)</h3>
|
|
<p>Specifies the sections of the report that you want to print.
|
|
</p>
|
|
<dl>
|
|
<dt><b><u>*ALL</u></b></dt>
|
|
<dd>All sections of the report are printed.
|
|
</dd>
|
|
<dt><b>*INTERVAL</b></dt>
|
|
<dd>Specifies that you want to print the Component Interval Activity section.
|
|
</dd>
|
|
<dt><b>*WORKLOAD</b></dt>
|
|
<dd>Specifies that you want to print the Job Workload Activity section.
|
|
</dd>
|
|
<dt><b>*POOL</b></dt>
|
|
<dd>Specifies that you want to print the Storage Pool Activity section.
|
|
</dd>
|
|
<dt><b>*DISK</b></dt>
|
|
<dd>Specifies that you want to print the Disk Activity section.
|
|
</dd>
|
|
<dt><b>*IOP</b></dt>
|
|
<dd>Specifies that you want to print the IOP Utilization section.
|
|
</dd>
|
|
<dt><b>*LCLWS</b></dt>
|
|
<dd>Specifies that you want to print the Local Work Stations section.
|
|
</dd>
|
|
<dt><b>*RMTWS</b></dt>
|
|
<dd>Specifies that you want to print the Remote Work Stations section. You can print this section only if you converted the performance data that was collected by the STRPFRMON command in a previous release. Collection Services does not collect this data.
|
|
</dd>
|
|
<dt><b>*EXCEPTION</b></dt>
|
|
<dd>Specifies that you want to print the Exception Occurrence Summary and Interval Counts section.
|
|
</dd>
|
|
<dt><b>*DBJRN</b></dt>
|
|
<dd>Specifies that you want to print the Database Journaling Summary section.
|
|
</dd>
|
|
<dt><b>*TCPIP</b></dt>
|
|
<dd>Specifies that you want to print the TCP/IP Activity section. This section is new since V5R1. It will not be available if you convert data from a previous release.
|
|
</dd>
|
|
<dt><b>*HTTP</b></dt>
|
|
<dd>Specifies that you want to print the HTTP Server Activity section. This section includes statistics for HTTP Server (powered by Apache).
|
|
</dd>
|
|
<dt><b>*DOMINO</b></dt>
|
|
<dd>Specifies that you want to print the Domino Server Activity section. This section includes statistics for Domino for iSeries.
|
|
</dd>
|
|
</dl>
|
|
</div>
|
|
<table width="100%">
|
|
<tr><td align="right"><a href="#PRTCPTRPT.Top_Of_Page">Top</a></td></tr>
|
|
</table>
|
|
<div> <a name="PRTCPTRPT.DETAIL"></a>
|
|
<h3>Report detail (DETAIL)</h3>
|
|
<p>Specifies whether you want the report to provide detailed job information at the job level or the thread level.
|
|
</p>
|
|
<dl>
|
|
<dt><b><u>*JOB</u></b></dt>
|
|
<dd>Specifies that you want detailed information at the job level.
|
|
</dd>
|
|
<dt><b>*THREAD</b></dt>
|
|
<dd>Specifies that you want detailed information at the thread level.
|
|
</dd>
|
|
</dl>
|
|
</div>
|
|
<table width="100%">
|
|
<tr><td align="right"><a href="#PRTCPTRPT.Top_Of_Page">Top</a></td></tr>
|
|
</table>
|
|
<div> <a name="PRTCPTRPT.SLTJOB"></a>
|
|
<h3>Select jobs (SLTJOB)</h3>
|
|
<p>Specifies a list of up to 50 jobs to be included in the report. Only specified jobs are included in the report.
|
|
</p>
|
|
<p>Individual jobs are identified by a "job identifier." A job identifier is either the special value *ALL or a qualified name that consists of up to three elements: a job number, a user name, and a job name. Job identifiers are written in the form, job-number/user-name/job-name, but all three elements do not have to be specified. The symbol *N can be used as a placeholder for up to two of the elements of the job identifier.
|
|
</p>
|
|
<p>
|
|
<b>Note: </b>This parameter and the <b>Omit jobs</b> prompt (OMTJOB parameter) are mutually exclusive.
|
|
</p>
|
|
<p>You can enter multiple values for this parameter.
|
|
</p>
|
|
<p><b>Element 1: Job name</b>
|
|
</p>
|
|
<dl>
|
|
<dt><b><u>*ALL</u></b></dt>
|
|
<dd>All jobs in the collected data are included, unless excluded by another selection value.
|
|
</dd>
|
|
<dt><b><i>job-name</i></b></dt>
|
|
<dd>Specify the names of the jobs to select. Because jobs may have identical job names, this value may not identify a specific job. A generic name can be specified for this value.
|
|
</dd>
|
|
</dl>
|
|
<p>
|
|
<b>Note: </b>A generic name is a character string that contains one or more characters followed by an asterisk(*), for example, ABC*. The asterisk substitutes for any valid characters. A generic name specifies all objects with names that begin with the generic prefix for which the user has authority. If an asterisk is not included with the generic name, the system assumes it to be the complete object name.
|
|
</p>
|
|
<dl>
|
|
<dt><b><i>job-number</i></b></dt>
|
|
<dd>Specify the 6-digit number of a job to select. All six digits must be specified, including zeros.
|
|
</dd>
|
|
<dt><b><i>user-name</i></b></dt>
|
|
<dd>Specify the user names of the jobs to select. Because jobs may have identical user names, this value may not identify a specific job.
|
|
</dd>
|
|
</dl>
|
|
<p><b>Element 2: Thread</b>
|
|
</p>
|
|
<dl>
|
|
<dt><b><u>*ALL</u></b></dt>
|
|
<dd>All threads are included, unless excluded by some other selection criterion.
|
|
</dd>
|
|
<dt><b><i>thread-identifier</i></b></dt>
|
|
<dd>Specify the thread identifier to select. Because some jobs can have identical thread identifiers, this value may not identify a specific job.
|
|
</dd>
|
|
</dl>
|
|
</div>
|
|
<table width="100%">
|
|
<tr><td align="right"><a href="#PRTCPTRPT.Top_Of_Page">Top</a></td></tr>
|
|
</table>
|
|
<div> <a name="PRTCPTRPT.OMTJOB"></a>
|
|
<h3>Omit jobs (OMTJOB)</h3>
|
|
<p>Specifies a list of up to 50 jobs to be omitted from the report.
|
|
</p>
|
|
<p>Individual jobs are identified by a "job identifier." A job identifier is either the special value *NONE or a qualified name that consists of up to three elements: a job number, a user name, and a job name. Job identifiers are written in the form, job-number/user-name/job-name, but all three elements do not have to be specified. The symbol *N can be used as a placeholder for up to two of the elements of the job identifier.
|
|
</p>
|
|
<p>
|
|
<b>Note: </b>This parameter and the <b>Select jobs</b> prompt (SLTJOB parameter) are mutually exclusive.
|
|
</p>
|
|
<p>You can enter multiple values for this parameter.
|
|
</p>
|
|
<p><b>Element 1: Job name</b>
|
|
</p>
|
|
<dl>
|
|
<dt><b><u>*NONE</u></b></dt>
|
|
<dd>Jobs are not excluded based on job identifier.
|
|
</dd>
|
|
<dt><b><i>job-name</i></b></dt>
|
|
<dd>Specify the names of the jobs to omit. Because jobs may have identical job names, this value may not identify a specific job. A generic name can be specified for this value.
|
|
</dd>
|
|
</dl>
|
|
<p>
|
|
<b>Note: </b>A generic name is a character string that contains one or more characters followed by an asterisk(*), for example, ABC*. The asterisk substitutes for any valid characters. A generic name specifies all objects with names that begin with the generic prefix for which the user has authority. If an asterisk is not included with the generic name, the system assumes it to be the complete object name.
|
|
</p>
|
|
<dl>
|
|
<dt><b><i>job-number</i></b></dt>
|
|
<dd>Specify the 6-digit number of a job to omit. All six digits must be specified, including zeros.
|
|
</dd>
|
|
<dt><b><i>user-name</i></b></dt>
|
|
<dd>Specify the user names of the jobs to omit. Because jobs may have identical user names, this value may not identify a specific job.
|
|
</dd>
|
|
</dl>
|
|
<p><b>Element 2: Thread</b>
|
|
</p>
|
|
<dl>
|
|
<dt><b><u>*ALL</u></b></dt>
|
|
<dd>All threads are included, unless excluded by some other selection criterion.
|
|
</dd>
|
|
<dt><b><i>thread-identifier</i></b></dt>
|
|
<dd>Specify the thread identifier to select. Because some jobs can have identical thread identifiers, this value may not identify a specific job.
|
|
</dd>
|
|
</dl>
|
|
</div>
|
|
<table width="100%">
|
|
<tr><td align="right"><a href="#PRTCPTRPT.Top_Of_Page">Top</a></td></tr>
|
|
</table>
|
|
<div> <a name="PRTCPTRPT.SLTUSRID"></a>
|
|
<h3>Select users (SLTUSRID)</h3>
|
|
<p>Specifies a list of up to 50 user names to be included in the report. Only jobs with one of the specified user names are included in the report.
|
|
</p>
|
|
<p>
|
|
<b>Note: </b>This parameter and the <b>Omit users</b> prompt (OMTUSRID parameter) are mutually exclusive.
|
|
</p>
|
|
<p>You can enter multiple values for this parameter.
|
|
</p>
|
|
<dl>
|
|
<dt><b><u>*ALL</u></b></dt>
|
|
<dd>All jobs with user names are included, unless excluded by another selection value.
|
|
</dd>
|
|
<dt><b><i>user-name</i></b></dt>
|
|
<dd>Specify the user names of the jobs to select. Because jobs may have identical user names, this value may not identify a specific job. A generic name may be specified for this value. SLTUSRID(user) is equivalent to SLTJOB(*N/user/*N).
|
|
</dd>
|
|
</dl>
|
|
<p>
|
|
<b>Note: </b>A generic name is a character string that contains one or more characters followed by an asterisk(*), for example, ABC*. The asterisk substitutes for any valid characters. A generic name specifies all objects with names that begin with the generic prefix for which the user has authority. If an asterisk is not included with the generic name, the system assumes it to be the complete object name.
|
|
</p>
|
|
</div>
|
|
<table width="100%">
|
|
<tr><td align="right"><a href="#PRTCPTRPT.Top_Of_Page">Top</a></td></tr>
|
|
</table>
|
|
<div> <a name="PRTCPTRPT.OMTUSRID"></a>
|
|
<h3>Omit users (OMTUSRID)</h3>
|
|
<p>Specifies a list of up to 50 user names to be omitted from the report.
|
|
</p>
|
|
<p>
|
|
<b>Note: </b>This parameter and the <b>Select users</b> prompt (SLTUSRID parameter) are mutually exclusive.
|
|
</p>
|
|
<p>You can enter multiple values for this parameter.
|
|
</p>
|
|
<dl>
|
|
<dt><b><u>*NONE</u></b></dt>
|
|
<dd>No jobs are excluded based on the user name.
|
|
</dd>
|
|
<dt><b><i>user-name</i></b></dt>
|
|
<dd>Specify the user names of the jobs to omit. Because jobs may have identical user names, this value may not identify a specific job. A generic name may be specified for this value. OMTUSRID(user) is equivalent to OMTJOB(*N/user/*N).
|
|
</dd>
|
|
</dl>
|
|
<p>
|
|
<b>Note: </b>A generic name is a character string that contains one or more characters followed by an asterisk(*), for example, ABC*. The asterisk substitutes for any valid characters. A generic name specifies all objects with names that begin with the generic prefix for which the user has authority. If an asterisk is not included with the generic name, the system assumes it to be the complete object name.
|
|
</p>
|
|
</div>
|
|
<table width="100%">
|
|
<tr><td align="right"><a href="#PRTCPTRPT.Top_Of_Page">Top</a></td></tr>
|
|
</table>
|
|
<div> <a name="PRTCPTRPT.SLTJOBTYPE"></a>
|
|
<h3>Select job type (SLTJOBTYPE)</h3>
|
|
<p>Specifies a list of up to 15 job types to be included in the report.
|
|
</p>
|
|
<p>
|
|
<b>Note: </b>This parameter and the <b>Omit job type</b> prompt (OMTJOBTYPE parameter) are mutually exclusive.
|
|
</p>
|
|
<p>You can enter multiple values for this parameter.
|
|
</p>
|
|
<dl>
|
|
<dt><b><u>*ALL</u></b></dt>
|
|
<dd>Jobs of all types are included, unless excluded by another selection value.
|
|
</dd>
|
|
<dt><b>A</b></dt>
|
|
<dd>Automatic start jobs
|
|
</dd>
|
|
<dt><b>B</b></dt>
|
|
<dd>Batch jobs
|
|
</dd>
|
|
<dt><b>C</b></dt>
|
|
<dd>iSeries Access jobs
|
|
</dd>
|
|
<dt><b>D</b></dt>
|
|
<dd>DDM server jobs
|
|
</dd>
|
|
<dt><b>E</b></dt>
|
|
<dd>Evoke jobs
|
|
</dd>
|
|
<dt><b>I</b></dt>
|
|
<dd>Interactive jobs
|
|
</dd>
|
|
<dt><b>L</b></dt>
|
|
<dd>Licensed Internal Code jobs
|
|
</dd>
|
|
<dt><b>M</b></dt>
|
|
<dd>Subsystem monitor jobs
|
|
</dd>
|
|
<dt><b>P</b></dt>
|
|
<dd>Pass-through jobs
|
|
</dd>
|
|
<dt><b>R</b></dt>
|
|
<dd>Spool reader jobs
|
|
</dd>
|
|
<dt><b>S</b></dt>
|
|
<dd>System jobs
|
|
</dd>
|
|
<dt><b>T</b></dt>
|
|
<dd>Multiple Requester Terminal (MRT) jobs
|
|
</dd>
|
|
<dt><b>W</b></dt>
|
|
<dd>Spool writer jobs
|
|
</dd>
|
|
<dt><b>X</b></dt>
|
|
<dd>Start system job
|
|
</dd>
|
|
<dt><b>3</b></dt>
|
|
<dd>System/36 jobs
|
|
</dd>
|
|
</dl>
|
|
</div>
|
|
<table width="100%">
|
|
<tr><td align="right"><a href="#PRTCPTRPT.Top_Of_Page">Top</a></td></tr>
|
|
</table>
|
|
<div> <a name="PRTCPTRPT.OMTJOBTYPE"></a>
|
|
<h3>Omit job type (OMTJOBTYPE)</h3>
|
|
<p>Specifies a list of up to 15 job types to be omitted from the report.
|
|
</p>
|
|
<p>
|
|
<b>Note: </b>This parameter and the <b>Select job type</b> prompt (SLTJOBTYPE parameter) are mutually exclusive.
|
|
</p>
|
|
<p>You can enter multiple values for this parameter.
|
|
</p>
|
|
<dl>
|
|
<dt><b><u>*NONE</u></b></dt>
|
|
<dd>No job types are excluded, unless excluded by another selection value.
|
|
</dd>
|
|
<dt><b>A</b></dt>
|
|
<dd>Automatic start jobs
|
|
</dd>
|
|
<dt><b>B</b></dt>
|
|
<dd>Batch jobs
|
|
</dd>
|
|
<dt><b>C</b></dt>
|
|
<dd>iSeries Access jobs
|
|
</dd>
|
|
<dt><b>D</b></dt>
|
|
<dd>DDM server jobs
|
|
</dd>
|
|
<dt><b>E</b></dt>
|
|
<dd>Evoke jobs
|
|
</dd>
|
|
<dt><b>I</b></dt>
|
|
<dd>Interactive jobs
|
|
</dd>
|
|
<dt><b>L</b></dt>
|
|
<dd>Licensed Internal Code jobs
|
|
</dd>
|
|
<dt><b>M</b></dt>
|
|
<dd>Subsystem monitor jobs
|
|
</dd>
|
|
<dt><b>P</b></dt>
|
|
<dd>Pass-through jobs
|
|
</dd>
|
|
<dt><b>R</b></dt>
|
|
<dd>Spool reader jobs
|
|
</dd>
|
|
<dt><b>S</b></dt>
|
|
<dd>System jobs
|
|
</dd>
|
|
<dt><b>T</b></dt>
|
|
<dd>Multiple Requester Terminal (MRT) jobs
|
|
</dd>
|
|
<dt><b>W</b></dt>
|
|
<dd>Spool writer jobs
|
|
</dd>
|
|
<dt><b>X</b></dt>
|
|
<dd>Start system job
|
|
</dd>
|
|
<dt><b>3</b></dt>
|
|
<dd>System/36 jobs
|
|
</dd>
|
|
</dl>
|
|
</div>
|
|
<table width="100%">
|
|
<tr><td align="right"><a href="#PRTCPTRPT.Top_Of_Page">Top</a></td></tr>
|
|
</table>
|
|
<div> <a name="PRTCPTRPT.SLTRUNPTY"></a>
|
|
<h3>Select job run priority (SLTRUNPTY)</h3>
|
|
<p>Specifies a range of run priorities to select. Only jobs that ran with a priority in the specified range will be included in the report.
|
|
</p>
|
|
<p>
|
|
<b>Note: </b>This parameter and the <b>Omit job run priority</b> (OMTRUNPTY parameter) are mutually exclusive.
|
|
</p>
|
|
<p><b>Single Value </b>
|
|
</p>
|
|
<dl>
|
|
<dt><b><u>*ALL</u></b></dt>
|
|
<dd>All jobs are included, unless excluded by another selection value.
|
|
</dd>
|
|
</dl>
|
|
<p><b>Element 1: Highest Job Run Priority </b>
|
|
</p>
|
|
<dl>
|
|
<dt><b><i>highest-priority</i></b></dt>
|
|
<dd>Specifies the highest run priority to select. Priorities can be 0 through 99, where 0 is the highest job priority and 99 is the lowest job priority.
|
|
</dd>
|
|
</dl>
|
|
<p><b>Element 2: Lowest Job Run Priority </b>
|
|
</p>
|
|
<dl>
|
|
<dt><b><i>lowest-priority</i></b></dt>
|
|
<dd>Specifies the lowest run priority to select. Priorities can be 0 through 99, where 0 is the highest job priority and 99 is the lowest job priority.
|
|
</dd>
|
|
</dl>
|
|
</div>
|
|
<table width="100%">
|
|
<tr><td align="right"><a href="#PRTCPTRPT.Top_Of_Page">Top</a></td></tr>
|
|
</table>
|
|
<div> <a name="PRTCPTRPT.OMTRUNPTY"></a>
|
|
<h3>Omit job run priority (OMTRUNPTY)</h3>
|
|
<p>Specifies a range of run priorities to omit. Only jobs that ran with a priority in the specified range will be excluded from the report.
|
|
</p>
|
|
<p>
|
|
<b>Note: </b>This parameter and the <b>Select job run priority</b> (SLTRUNPTY) parameter are mutually exclusive.
|
|
</p>
|
|
<p><b>Single Value </b>
|
|
</p>
|
|
<dl>
|
|
<dt><b><u>*NONE</u></b></dt>
|
|
<dd>No jobs are excluded based on their priority.
|
|
</dd>
|
|
</dl>
|
|
<p><b>Element 1: Highest Job Run Priority </b>
|
|
</p>
|
|
<dl>
|
|
<dt><b><i>highest-priority</i></b></dt>
|
|
<dd>Specifies the highest run priority to omit. Priorities can be 0 through 99, where 0 is the highest job priority and 99 is the lowest job priority.
|
|
</dd>
|
|
</dl>
|
|
<p><b>Element 2: Lowest Job Run Priority </b>
|
|
</p>
|
|
<dl>
|
|
<dt><b><i>lowest-priority</i></b></dt>
|
|
<dd>Specifies the lowest run priority to omit. Priorities can be 0 through 99, where 0 is the highest job priority and 99 is the lowest job priority.
|
|
</dd>
|
|
</dl>
|
|
</div>
|
|
<table width="100%">
|
|
<tr><td align="right"><a href="#PRTCPTRPT.Top_Of_Page">Top</a></td></tr>
|
|
</table>
|
|
<div> <a name="PRTCPTRPT.SLTPOOLS"></a>
|
|
<h3>Select pools (SLTPOOLS)</h3>
|
|
<p>Specifies a list of up to 64 pools to be included in the report.
|
|
</p>
|
|
<p>
|
|
<b>Note: </b>This parameter and the <b>Omit pools</b> prompt (OMTPOOLS parameter) are mutually exclusive.
|
|
</p>
|
|
<p>You can enter multiple values for this parameter.
|
|
</p>
|
|
<dl>
|
|
<dt><b><u>*ALL</u></b></dt>
|
|
<dd>Jobs that ran in all pools are included, unless excluded by another selection value.
|
|
</dd>
|
|
<dt><b><i>storage-pool-identifier</i></b></dt>
|
|
<dd>Specify the number of a pool to select. Valid values range from 1 through 64.
|
|
</dd>
|
|
</dl>
|
|
</div>
|
|
<table width="100%">
|
|
<tr><td align="right"><a href="#PRTCPTRPT.Top_Of_Page">Top</a></td></tr>
|
|
</table>
|
|
<div> <a name="PRTCPTRPT.OMTPOOLS"></a>
|
|
<h3>Omit pools (OMTPOOLS)</h3>
|
|
<p>Specifies a list of up to 64 pools to omit. Jobs that ran in any of the specified pools are excluded from the report.
|
|
</p>
|
|
<p>
|
|
<b>Note: </b>This parameter and the <b>Select pools</b> prompt (SLTPOOLS parameter) are mutually exclusive.
|
|
</p>
|
|
<p>You can enter multiple values for this parameter.
|
|
</p>
|
|
<dl>
|
|
<dt><b><u>*NONE</u></b></dt>
|
|
<dd>Jobs are not excluded based on their pool.
|
|
</dd>
|
|
<dt><b><i>storage-pool-identifier</i></b></dt>
|
|
<dd>Specify the number of a pool to omit. Valid values range from 1 through 64.
|
|
</dd>
|
|
</dl>
|
|
</div>
|
|
<table width="100%">
|
|
<tr><td align="right"><a href="#PRTCPTRPT.Top_Of_Page">Top</a></td></tr>
|
|
</table>
|
|
<div> <a name="PRTCPTRPT.SLTSBS"></a>
|
|
<h3>Select subsystems (SLTSBS)</h3>
|
|
<p>Specifies a list of up 50 subsystems to select. Only jobs that ran in one of the specified subsystems are included in the report.
|
|
</p>
|
|
<p>
|
|
<b>Note: </b>This parameter and the <b>Omit subsystems</b> prompt (OMTSBS parameter) are mutually exclusive.
|
|
</p>
|
|
<p>You can enter multiple values for this parameter.
|
|
</p>
|
|
<dl>
|
|
<dt><b><u>*ALL</u></b></dt>
|
|
<dd>Jobs in all subsystems are included, unless excluded by another selection value.
|
|
</dd>
|
|
<dt><b><i>subsystem-name</i></b></dt>
|
|
<dd>Specify the name of a subsystem to select.
|
|
</dd>
|
|
</dl>
|
|
</div>
|
|
<table width="100%">
|
|
<tr><td align="right"><a href="#PRTCPTRPT.Top_Of_Page">Top</a></td></tr>
|
|
</table>
|
|
<div> <a name="PRTCPTRPT.OMTSBS"></a>
|
|
<h3>Omit subsystems (OMTSBS)</h3>
|
|
<p>Specifies a list of up to 50 subsystems to omit. Jobs that ran in any of the specified subsystems are excluded from the report.
|
|
</p>
|
|
<p>
|
|
<b>Note: </b>This parameter and the <b>Select subsystems</b> prompt (SLTSBS parameter) are mutually exclusive.
|
|
</p>
|
|
<p>You can enter multiple values for this parameter.
|
|
</p>
|
|
<dl>
|
|
<dt><b><u>*NONE</u></b></dt>
|
|
<dd>Jobs are not excluded based on their subsystem.
|
|
</dd>
|
|
<dt><b><i>subsystem-name</i></b></dt>
|
|
<dd>Specify the name of a subsystem to omit.
|
|
</dd>
|
|
</dl>
|
|
</div>
|
|
<table width="100%">
|
|
<tr><td align="right"><a href="#PRTCPTRPT.Top_Of_Page">Top</a></td></tr>
|
|
</table>
|
|
<div> <a name="PRTCPTRPT.SLTLINE"></a>
|
|
<h3>Select communications lines (SLTLINE)</h3>
|
|
<p>Specifies a list of up to 50 communications lines to select. Only jobs that use a remote device connected through one of the specified communications lines are included in the report.
|
|
</p>
|
|
<p>
|
|
<b>Note: </b>This parameter and the <b>Omit communications lines</b> prompt (OMTLINE parameter) are mutually exclusive.
|
|
</p>
|
|
<p>You can enter multiple values for this parameter.
|
|
</p>
|
|
<dl>
|
|
<dt><b><u>*ALL</u></b></dt>
|
|
<dd>All jobs are included in the report, unless excluded by another selection value.
|
|
</dd>
|
|
<dt><b><i>communication-line-name</i></b></dt>
|
|
<dd>Specify the name of a communications line to select. This excludes jobs using remote devices connected through other communications lines, even if the controllers to which those devices are attached are specified on the <b>Select control units</b> prompt (SLTCTL parameter).
|
|
</dd>
|
|
</dl>
|
|
</div>
|
|
<table width="100%">
|
|
<tr><td align="right"><a href="#PRTCPTRPT.Top_Of_Page">Top</a></td></tr>
|
|
</table>
|
|
<div> <a name="PRTCPTRPT.OMTLINE"></a>
|
|
<h3>Omit communications lines (OMTLINE)</h3>
|
|
<p>Specifies a list of up to 50 communications lines to omit. Jobs that use a remote device connected through any of the specified communications lines are excluded from the report.
|
|
</p>
|
|
<p>
|
|
<b>Note: </b>This parameter and the <b>Select communications lines</b> prompt (SLTLINE parameter) are mutually exclusive.
|
|
</p>
|
|
<p>You can enter multiple values for this parameter.
|
|
</p>
|
|
<dl>
|
|
<dt><b><u>*NONE</u></b></dt>
|
|
<dd>Jobs are not excluded from the report based on communications line.
|
|
</dd>
|
|
<dt><b><i>communication-line-name</i></b></dt>
|
|
<dd>Specify the name of a communications line to omit.
|
|
</dd>
|
|
</dl>
|
|
</div>
|
|
<table width="100%">
|
|
<tr><td align="right"><a href="#PRTCPTRPT.Top_Of_Page">Top</a></td></tr>
|
|
</table>
|
|
<div> <a name="PRTCPTRPT.SLTCTL"></a>
|
|
<h3>Select control units (SLTCTL)</h3>
|
|
<p>Specifies a list of up to 50 communications controllers to select. Only jobs that use a device connected to one of the specified controllers are included in the report.
|
|
</p>
|
|
<p>
|
|
<b>Note: </b>This parameter and the <b>Omit control units</b> prompt (OMTCTL parameter) are mutually exclusive.
|
|
</p>
|
|
<p>You can enter multiple values for this parameter.
|
|
</p>
|
|
<dl>
|
|
<dt><b><u>*ALL</u></b></dt>
|
|
<dd>All jobs are included, unless excluded by another selection value.
|
|
</dd>
|
|
<dt><b><i>controller-name</i></b></dt>
|
|
<dd>Specify the name of a communications controller to select.
|
|
</dd>
|
|
</dl>
|
|
</div>
|
|
<table width="100%">
|
|
<tr><td align="right"><a href="#PRTCPTRPT.Top_Of_Page">Top</a></td></tr>
|
|
</table>
|
|
<div> <a name="PRTCPTRPT.OMTCTL"></a>
|
|
<h3>Omit control units (OMTCTL)</h3>
|
|
<p>Specifies a list of up to 50 communications controllers to omit. Jobs that use a device connected to any of the specified controllers are excluded from in the report.
|
|
</p>
|
|
<p>
|
|
<b>Note: </b>This parameter and the <b>Select control units</b> prompt (SLTCTL parameter) are mutually exclusive.
|
|
</p>
|
|
<p>You can enter multiple values for this parameter.
|
|
</p>
|
|
<dl>
|
|
<dt><b><u>*NONE</u></b></dt>
|
|
<dd>Jobs are not excluded based on communications controllers.
|
|
</dd>
|
|
<dt><b><i>controller-name</i></b></dt>
|
|
<dd>Specify the name of a communications controller to omit.
|
|
</dd>
|
|
</dl>
|
|
</div>
|
|
<table width="100%">
|
|
<tr><td align="right"><a href="#PRTCPTRPT.Top_Of_Page">Top</a></td></tr>
|
|
</table>
|
|
<div> <a name="PRTCPTRPT.SLTFCNARA"></a>
|
|
<h3>Select functional areas (SLTFCNARA)</h3>
|
|
<p>Specifies a list of up to 50 functional areas to select. Only jobs and users identified in one of the functional areas are included in the report.
|
|
</p>
|
|
<p>A functional area is a list of job names and/or user names previously defined by the user. More information on functional areas is in the Performance Tools for iSeries book.
|
|
</p>
|
|
<p>
|
|
<b>Note: </b>This parameter and the <b>Omit functional areas</b> prompt (OMTFCNARA parameter) are mutually exclusive.
|
|
</p>
|
|
<p>You can enter multiple values for this parameter.
|
|
</p>
|
|
<dl>
|
|
<dt><b><u>*ALL</u></b></dt>
|
|
<dd>All jobs are included in the report, unless excluded by another selection value.
|
|
</dd>
|
|
<dt><b><i>functional-area-name</i></b></dt>
|
|
<dd>Specify the name of a functional area to select.
|
|
</dd>
|
|
</dl>
|
|
</div>
|
|
<table width="100%">
|
|
<tr><td align="right"><a href="#PRTCPTRPT.Top_Of_Page">Top</a></td></tr>
|
|
</table>
|
|
<div> <a name="PRTCPTRPT.OMTFCNARA"></a>
|
|
<h3>Omit functional areas (OMTFCNARA)</h3>
|
|
<p>Specifies a list of up to 50 functional areas to omit. Jobs and users identified in any of the functional areas are excluded from the report.
|
|
</p>
|
|
<p>A functional area is a list of job names and/or user names previously defined by the user. More information on functional areas is in the Performance Tools for iSeries book.
|
|
</p>
|
|
<p>
|
|
<b>Note: </b>This parameter and the <b>Select functional areas</b> prompt (SLTFCNARA parameter) are mutually exclusive.
|
|
</p>
|
|
<p>You can enter multiple values for this parameter.
|
|
</p>
|
|
<dl>
|
|
<dt><b><u>*NONE</u></b></dt>
|
|
<dd>Jobs are not excluded from the report based on functional area.
|
|
</dd>
|
|
<dt><b><i>functional-area-name</i></b></dt>
|
|
<dd>Specify the name of a functional area to omit.
|
|
</dd>
|
|
</dl>
|
|
</div>
|
|
<table width="100%">
|
|
<tr><td align="right"><a href="#PRTCPTRPT.Top_Of_Page">Top</a></td></tr>
|
|
</table>
|
|
<div> <a name="PRTCPTRPT.JOB"></a>
|
|
<h3>Job name (JOB)</h3>
|
|
<p>Specifies the job name to be used if submitting the job for batch processing.
|
|
</p>
|
|
<p>Any value for this parameter is ignored if *NONE is specified for the <b>Job description</b> prompt (JOBD parameter).
|
|
</p>
|
|
<p>
|
|
<b>Note: </b>If *NONE is specified for the <b>Job description</b> prompt (JOBD parameter), job processing is performed interactively.
|
|
</p>
|
|
<p>The possible <b>job name</b> values are:
|
|
</p>
|
|
<dl>
|
|
<dt><b><u>PRTCPTRPT</u></b></dt>
|
|
<dd>The command name is used for the job name.
|
|
</dd>
|
|
<dt><b>*MBR</b></dt>
|
|
<dd>The name selected for the performance data member in the <b>Member</b> prompt (MBR parameter) is used.
|
|
</dd>
|
|
<dt><b><i>job-name</i></b></dt>
|
|
<dd>Specify the name to be used for any and all batch jobs.
|
|
</dd>
|
|
</dl>
|
|
</div>
|
|
<table width="100%">
|
|
<tr><td align="right"><a href="#PRTCPTRPT.Top_Of_Page">Top</a></td></tr>
|
|
</table>
|
|
<div> <a name="PRTCPTRPT.JOBD"></a>
|
|
<h3>Job description (JOBD)</h3>
|
|
<p>Specifies the job description used to submit the job for batch processing.
|
|
</p>
|
|
<p>The possible job description values are:
|
|
</p>
|
|
<dl>
|
|
<dt><b><u>QPFRJOBD</u></b></dt>
|
|
<dd>The IBM-supplied job description, QPFRJOBD, is used.
|
|
</dd>
|
|
<dt><b><i>job-description-name</i></b></dt>
|
|
<dd>Specify the name of an alternate job description.
|
|
</dd>
|
|
<dt><b>*NONE</b></dt>
|
|
<dd>A batch job is not submitted; processing continues interactively while the user waits. The user's workstation is not available for other use during this time, which could be significant for long jobs.
|
|
</dd>
|
|
</dl>
|
|
<p>The possible library values are:
|
|
</p>
|
|
<dl>
|
|
<dt><b><u>*LIBL</u></b></dt>
|
|
<dd>All libraries in the job's library list are searched until the first match is found.
|
|
</dd>
|
|
<dt><b>*CURLIB</b></dt>
|
|
<dd>The current library for the job is used to locate the job description. If no current library entry exists in the library list, QGPL is used.
|
|
</dd>
|
|
<dt><b><i>library-name</i></b></dt>
|
|
<dd>Specify the library in which the job description is located.
|
|
</dd>
|
|
</dl>
|
|
</div>
|
|
<table width="100%">
|
|
<tr><td align="right"><a href="#PRTCPTRPT.Top_Of_Page">Top</a></td></tr>
|
|
</table>
|
|
<hr size="2" width="100%">
|
|
<div><h3><a name="PRTCPTRPT.COMMAND.EXAMPLES">Examples</a> </h3>
|
|
<p><b>Example 1: Printing a Component Report</b>
|
|
</p>
|
|
<p>
|
|
<pre>
|
|
PRTCPTRPT MBR(APRIL18)
|
|
</pre>
|
|
</p>
|
|
<p>This command prints a complete component report for the performance data member APRIL18 in library QPFRDATA. The report title is the same as the text in the member.
|
|
</p>
|
|
<p><b>Example 2: Printing a Report With a Title</b>
|
|
</p>
|
|
<p>
|
|
<pre>
|
|
PRTCPTRPT MBR(NOV1) PERIOD(*SELECT)
|
|
TITLE('Intervals with Highest Response Times')
|
|
</pre>
|
|
</p>
|
|
<p>This command prints a component report for the data member NOV1 in library QPFRDATA. The user is presented with the interval-selection display, which allows sorting of the intervals according to various criteria and selection of only certain intervals to be included in the report. The title of the report is <i>Intervals with Highest Response Times</i>.
|
|
</p>
|
|
</div>
|
|
<table width="100%">
|
|
<tr><td align="right"><a href="#PRTCPTRPT.Top_Of_Page">Top</a></td></tr>
|
|
</table>
|
|
<hr size="2" width="100%">
|
|
<div><h3><a name="PRTCPTRPT.ERROR.MESSAGES">Error messages</a> </h3>
|
|
<p><b><u>*ESCAPE Messages</u></b>
|
|
</p>
|
|
<dl>
|
|
<dt><b>PFR1010</b></dt>
|
|
<dd>Cannot process request because of missing data.
|
|
</dd>
|
|
<dt><b>PFR3002</b></dt>
|
|
<dd>Cannot print report because of missing data.
|
|
</dd>
|
|
<dt><b>PFR3004</b></dt>
|
|
<dd>Incorrect measurement interval specified.
|
|
</dd>
|
|
<dt><b>PFR3006</b></dt>
|
|
<dd>Measurement interval specified is not valid.
|
|
</dd>
|
|
<dt><b>PFR3111</b></dt>
|
|
<dd>Functional area &1 does not exist.
|
|
</dd>
|
|
<dt><b>PFR5501</b></dt>
|
|
<dd>Performance data file(s) are not upward compatible.
|
|
</dd>
|
|
<dt><b>PFR5502</b></dt>
|
|
<dd>Performance data file(s) are not downward compatible.
|
|
</dd>
|
|
<dt><b>PFR9048</b></dt>
|
|
<dd>Cannot display graph because of missing data.
|
|
</dd>
|
|
</dl>
|
|