<h2>Create Device Desc (Display) (CRTDEVDSP)</h2>
|
|
<table width="100%">
|
|
<tr>
|
|
<td valign="top" align="left"><b>Where allowed to run: </b>All environments (*ALL)<br>
|
|
<b>Threadsafe: </b>No
|
|
</td>
|
|
<td valign="top" align="right">
|
|
<a href="#CRTDEVDSP.PARAMETERS.TABLE">Parameters</a><br>
|
|
<a href="#CRTDEVDSP.COMMAND.EXAMPLES">Examples</a><br>
|
|
<a href="#CRTDEVDSP.ERROR.MESSAGES">Error messages</a></td>
|
|
</tr>
|
|
</table>
|
|
|
|
<div> <a name="CRTDEVDSP"></a>
|
|
<p>The Create Device Description (Display) (CRTDEVDSP) command creates a device description for a display device.
|
|
</p>
|
|
</div>
|
|
<table width="100%">
|
|
<tr><td align="right"><a href="#CRTDEVDSP.Top_Of_Page">Top</a></td></tr>
|
|
</table>
|
|
<hr size="2" width="100%">
|
|
|
|
<div>
|
|
<h3><a name="CRTDEVDSP.PARAMETERS.TABLE">Parameters</a></h3>
|
|
<table border="1" cellpadding="4" cellspacing="0">
|
|
<!-- col1="10" col2="15" col3="30" col4="10" -->
|
|
<tr>
|
|
<th bgcolor="aqua" valign="bottom" align="left">Keyword</th>
|
|
<th bgcolor="aqua" valign="bottom" align="left">Description</th>
|
|
<th bgcolor="aqua" valign="bottom" align="left">Choices</th>
|
|
<th bgcolor="aqua" valign="bottom" align="left">Notes</th>
|
|
</tr>
|
|
<tr>
|
|
<td valign="top"><a href="#CRTDEVDSP.DEVD"><b>DEVD</b></a></td>
|
|
<td valign="top">Device description</td>
|
|
<td valign="top"><i>Name</i></td>
|
|
<td valign="top">Required, Positional 1</td>
|
|
</tr>
|
|
<tr>
|
|
<td valign="top"><a href="#CRTDEVDSP.DEVCLS"><b>DEVCLS</b></a></td>
|
|
<td valign="top">Device class</td>
|
|
<td valign="top">*LCL, *RMT, *VRT, *SNPT</td>
|
|
<td valign="top">Required, Positional 2</td>
|
|
</tr>
|
|
<tr>
|
|
<td valign="top"><a href="#CRTDEVDSP.TYPE"><b>TYPE</b></a></td>
|
|
<td valign="top">Device type</td>
|
|
<td valign="top">3101, 3151, 3161, 3162, 3163, 3164, 3179, 3180, 3196, 3197, 3277, 3278, 3279, 3476, 3477, 3486, 3487, 5150, 5251, 5291, 5292, 5555, D220, T910, T925, T955, V100, V220, W30, W50, W60, *CALC, *NVT</td>
|
|
<td valign="top">Required, Positional 3</td>
|
|
</tr>
|
|
<tr>
|
|
<td valign="top"><a href="#CRTDEVDSP.MODEL"><b>MODEL</b></a></td>
|
|
<td valign="top">Device model</td>
|
|
<td valign="top">0, 1, 2, 4, 5, 11, 3, 12, 23, 31, 32, 41, *ASCII, *DHCF, A1, A2, B1, B2, BA, B01, C01, E01, F01, G01, G02, C1, C2, D1, D2, EA, FA, FC, FD, EC, FE, FG, FW, HC, HG, HA, HW, W1, W2, 0000, 0001, 0002, 0004, 0005, 0011, 0003, 0012, 0023, 0031, 0032, 0041</td>
|
|
<td valign="top">Required, Positional 4</td>
|
|
</tr>
|
|
<tr>
|
|
<td valign="top"><a href="#CRTDEVDSP.EMLDEV"><b>EMLDEV</b></a></td>
|
|
<td valign="top">Emulated twinaxial device</td>
|
|
<td valign="top">3196A2, 3197D2, <b><u>*TYPE</u></b></td>
|
|
<td valign="top">Optional</td>
|
|
</tr>
|
|
<tr>
|
|
<td valign="top"><a href="#CRTDEVDSP.PORT"><b>PORT</b></a></td>
|
|
<td valign="top">Port number</td>
|
|
<td valign="top">0-17</td>
|
|
<td valign="top">Optional</td>
|
|
</tr>
|
|
<tr>
|
|
<td valign="top"><a href="#CRTDEVDSP.SWTSET"><b>SWTSET</b></a></td>
|
|
<td valign="top">Switch setting</td>
|
|
<td valign="top">0, 1, 2, 3, 4, 5, 6</td>
|
|
<td valign="top">Optional</td>
|
|
</tr>
|
|
<tr>
|
|
<td valign="top"><a href="#CRTDEVDSP.SHRSSNNBR"><b>SHRSSNNBR</b></a></td>
|
|
<td valign="top">Shared session number</td>
|
|
<td valign="top"><b><u>0</u></b>, 1, 2, 3</td>
|
|
<td valign="top">Optional</td>
|
|
</tr>
|
|
<tr>
|
|
<td valign="top"><a href="#CRTDEVDSP.LOCADR"><b>LOCADR</b></a></td>
|
|
<td valign="top">Local location address</td>
|
|
<td valign="top">00-FE</td>
|
|
<td valign="top">Optional</td>
|
|
</tr>
|
|
<tr>
|
|
<td valign="top"><a href="#CRTDEVDSP.EMLASCII"><b>EMLASCII</b></a></td>
|
|
<td valign="top">Emulating ASCII device</td>
|
|
<td valign="top"><b><u>*NO</u></b>, *YES</td>
|
|
<td valign="top">Optional</td>
|
|
</tr>
|
|
<tr>
|
|
<td valign="top"><a href="#CRTDEVDSP.ATTACH"><b>ATTACH</b></a></td>
|
|
<td valign="top">Physical attachment</td>
|
|
<td valign="top">*DIRECT, *PTT, *MODEM, *WIRE3, *WIRE4, *EIA422</td>
|
|
<td valign="top">Optional</td>
|
|
</tr>
|
|
<tr>
|
|
<td valign="top"><a href="#CRTDEVDSP.ONLINE"><b>ONLINE</b></a></td>
|
|
<td valign="top">Online at IPL</td>
|
|
<td valign="top"><b><u>*YES</u></b>, *NO</td>
|
|
<td valign="top">Optional</td>
|
|
</tr>
|
|
<tr>
|
|
<td valign="top"><a href="#CRTDEVDSP.CTL"><b>CTL</b></a></td>
|
|
<td valign="top">Attached controller</td>
|
|
<td valign="top"><i>Name</i></td>
|
|
<td valign="top">Optional</td>
|
|
</tr>
|
|
<tr>
|
|
<td valign="top"><a href="#CRTDEVDSP.KBDTYPE"><b>KBDTYPE</b></a></td>
|
|
<td valign="top">Keyboard language type</td>
|
|
<td valign="top"><b><u>*SYSVAL</u></b>, AGB, AGE, AGI, AGM, ALI, ALM, BGB, BGE, BLI, BLM, BRB, BRE, CAB, CAE, CAI, CAM, CLB, CLE, CSB, CSE, CYB, DMB, DME, DMI, DMM, ESB, FAB, FAE, FAI, FAM, FNB, FNE, FNI, FNM, FQB, FQI, GKB, GNB, GNE, HIB, HNB, HNE, ICB, ICE, ICI, ICM, INB, INI, IRB, ITB, ITE, ITI, ITM, JEB, JEI, JKB, JPB, JPE, JUB, KAB, KOB, LAB, LAE, LTB, LVB, MKB, MKE, NCB, NCE, NEB, NEE, NEI, NEM, NWB, NWE, NWI, NWM, PLB, PLE, PKB, PKE, PRB, PRE, PRI, PRM, RCB, RMB, RME, ROB, ROE, RUB, RUE, SFI, SFM, SGI, SGM, SKB, SKE, SPB, SPE, SPI, SPM, SQB, SQE, SSB, SSE, SSM, SSI, SWB, SWE, SWI, SWM, TAB, THB, THE, TKB, TKE, TRB, TRE, UAB, UAE, UKB, UKE, UKI, UKM, USB, USE, USI, USM, VNB, VNE, YGI, YGM</td>
|
|
<td valign="top">Optional</td>
|
|
</tr>
|
|
<tr>
|
|
<td valign="top"><a href="#CRTDEVDSP.DROP"><b>DROP</b></a></td>
|
|
<td valign="top">Drop line at signoff</td>
|
|
<td valign="top"><b><u>*YES</u></b>, *NO</td>
|
|
<td valign="top">Optional</td>
|
|
</tr>
|
|
<tr>
|
|
<td valign="top"><a href="#CRTDEVDSP.ALWBLN"><b>ALWBLN</b></a></td>
|
|
<td valign="top">Allow blinking cursor</td>
|
|
<td valign="top"><b><u>*YES</u></b>, *NO</td>
|
|
<td valign="top">Optional</td>
|
|
</tr>
|
|
<tr>
|
|
<td valign="top" rowspan="3"><a href="#CRTDEVDSP.AUXDEV"><b>AUXDEV</b></a></td>
|
|
<td valign="top">Auxiliary device</td>
|
|
<td valign="top">Values (up to 31 repetitions): <i>Element list</i></td>
|
|
<td valign="top" rowspan="3">Optional</td>
|
|
</tr>
|
|
<tr>
|
|
<td valign="top">Element 1: Auxiliary device type</td>
|
|
<td valign="top">
|
|
6180, 6182, 6184, 6185, 6186M1, 6186M2, 7371, 7372</td>
|
|
</tr>
|
|
<tr>
|
|
<td valign="top">Element 2: Auxiliary device address</td>
|
|
<td valign="top">
|
|
1-31</td>
|
|
</tr>
|
|
<tr>
|
|
<td valign="top"><a href="#CRTDEVDSP.PRINTER"><b>PRINTER</b></a></td>
|
|
<td valign="top">Printer</td>
|
|
<td valign="top"><i>Name</i></td>
|
|
<td valign="top">Optional</td>
|
|
</tr>
|
|
<tr>
|
|
<td valign="top"><a href="#CRTDEVDSP.MAXLENRU"><b>MAXLENRU</b></a></td>
|
|
<td valign="top">Maximum length of request unit</td>
|
|
<td valign="top"><b><u>*CALC</u></b>, 241, 245, 247, 256</td>
|
|
<td valign="top">Optional</td>
|
|
</tr>
|
|
<tr>
|
|
<td valign="top"><a href="#CRTDEVDSP.APPTYPE"><b>APPTYPE</b></a></td>
|
|
<td valign="top">Application type</td>
|
|
<td valign="top"><b><u>*NONE</u></b>, *NRF, *CTLSSN, *DEVINIT, *APPINIT</td>
|
|
<td valign="top">Optional</td>
|
|
</tr>
|
|
<tr>
|
|
<td valign="top"><a href="#CRTDEVDSP.ACTTMR"><b>ACTTMR</b></a></td>
|
|
<td valign="top">Activation timer</td>
|
|
<td valign="top">1-2550, <b><u>170</u></b></td>
|
|
<td valign="top">Optional</td>
|
|
</tr>
|
|
<tr>
|
|
<td valign="top"><a href="#CRTDEVDSP.INACTTMR"><b>INACTTMR</b></a></td>
|
|
<td valign="top">Inactivity timer</td>
|
|
<td valign="top">1-30, <b><u>*ATTACH</u></b>, *NOMAX, *SEC15, *SEC30</td>
|
|
<td valign="top">Optional</td>
|
|
</tr>
|
|
<tr>
|
|
<td valign="top"><a href="#CRTDEVDSP.SNPTDEV"><b>SNPTDEV</b></a></td>
|
|
<td valign="top">SNA pass-through device desc</td>
|
|
<td valign="top"><i>Name</i>, <b><u>*NONE</u></b></td>
|
|
<td valign="top">Optional</td>
|
|
</tr>
|
|
<tr>
|
|
<td valign="top"><a href="#CRTDEVDSP.SNPTGRP"><b>SNPTGRP</b></a></td>
|
|
<td valign="top">SNA pass-through group name</td>
|
|
<td valign="top"><i>Name</i>, <b><u>*NONE</u></b></td>
|
|
<td valign="top">Optional</td>
|
|
</tr>
|
|
<tr>
|
|
<td valign="top"><a href="#CRTDEVDSP.LOGON"><b>LOGON</b></a></td>
|
|
<td valign="top">Host signon/logon command</td>
|
|
<td valign="top"><i>Character value</i>, <b><u>*NONE</u></b></td>
|
|
<td valign="top">Optional</td>
|
|
</tr>
|
|
<tr>
|
|
<td valign="top"><a href="#CRTDEVDSP.LINESPEED"><b>LINESPEED</b></a></td>
|
|
<td valign="top">Line speed</td>
|
|
<td valign="top"><b><u>*TYPE</u></b>, *CALC, 150, 300, 600, 1200, 1800, 2400, 3600, 4800, 7200, 9600, 19200, 38400</td>
|
|
<td valign="top">Optional</td>
|
|
</tr>
|
|
<tr>
|
|
<td valign="top"><a href="#CRTDEVDSP.WORDLEN"><b>WORDLEN</b></a></td>
|
|
<td valign="top">Word length</td>
|
|
<td valign="top"><b><u>*TYPE</u></b>, *CALC, 7, 8</td>
|
|
<td valign="top">Optional</td>
|
|
</tr>
|
|
<tr>
|
|
<td valign="top"><a href="#CRTDEVDSP.PARITY"><b>PARITY</b></a></td>
|
|
<td valign="top">Type of parity</td>
|
|
<td valign="top"><b><u>*TYPE</u></b>, *CALC, *EVEN, *ODD, *NONE, *MARK, *SPACE</td>
|
|
<td valign="top">Optional</td>
|
|
</tr>
|
|
<tr>
|
|
<td valign="top"><a href="#CRTDEVDSP.STOPBITS"><b>STOPBITS</b></a></td>
|
|
<td valign="top">Stop bits</td>
|
|
<td valign="top"><b><u>*TYPE</u></b>, 1, 2</td>
|
|
<td valign="top">Optional</td>
|
|
</tr>
|
|
<tr>
|
|
<td valign="top"><a href="#CRTDEVDSP.MAXOUT"><b>MAXOUT</b></a></td>
|
|
<td valign="top">Maximum outstanding frames</td>
|
|
<td valign="top">1-7, <b><u>7</u></b></td>
|
|
<td valign="top">Optional</td>
|
|
</tr>
|
|
<tr>
|
|
<td valign="top"><a href="#CRTDEVDSP.IDLTMR"><b>IDLTMR</b></a></td>
|
|
<td valign="top">Idle timer</td>
|
|
<td valign="top">10-250, <b><u>40</u></b></td>
|
|
<td valign="top">Optional</td>
|
|
</tr>
|
|
<tr>
|
|
<td valign="top"><a href="#CRTDEVDSP.NRMPOLLTMR"><b>NRMPOLLTMR</b></a></td>
|
|
<td valign="top">NRM poll timer</td>
|
|
<td valign="top">2-100, <b><u>3</u></b></td>
|
|
<td valign="top">Optional</td>
|
|
</tr>
|
|
<tr>
|
|
<td valign="top"><a href="#CRTDEVDSP.FRAMERTY"><b>FRAMERTY</b></a></td>
|
|
<td valign="top">Frame retry</td>
|
|
<td valign="top">5-64, <b><u>15</u></b></td>
|
|
<td valign="top">Optional</td>
|
|
</tr>
|
|
<tr>
|
|
<td valign="top"><a href="#CRTDEVDSP.RMTLOCNAME"><b>RMTLOCNAME</b></a></td>
|
|
<td valign="top">Remote location</td>
|
|
<td valign="top"><i>Communications name</i></td>
|
|
<td valign="top">Optional</td>
|
|
</tr>
|
|
<tr>
|
|
<td valign="top"><a href="#CRTDEVDSP.LCLLOCNAME"><b>LCLLOCNAME</b></a></td>
|
|
<td valign="top">Local location</td>
|
|
<td valign="top"><i>Communications name</i>, <b><u>*NETATR</u></b></td>
|
|
<td valign="top">Optional</td>
|
|
</tr>
|
|
<tr>
|
|
<td valign="top"><a href="#CRTDEVDSP.RMTNETID"><b>RMTNETID</b></a></td>
|
|
<td valign="top">Remote network identifier</td>
|
|
<td valign="top"><i>Communications name</i>, <b><u>*NETATR</u></b>, *NONE</td>
|
|
<td valign="top">Optional</td>
|
|
</tr>
|
|
<tr>
|
|
<td valign="top" rowspan="3"><a href="#CRTDEVDSP.IGCFEAT"><b>IGCFEAT</b></a></td>
|
|
<td valign="top">DBCS feature</td>
|
|
<td valign="top"><i>Element list</i></td>
|
|
<td valign="top" rowspan="3">Optional</td>
|
|
</tr>
|
|
<tr>
|
|
<td valign="top">Element 1: Device features</td>
|
|
<td valign="top">
|
|
<i>Character value</i></td>
|
|
</tr>
|
|
<tr>
|
|
<td valign="top">Element 2: Last code point</td>
|
|
<td valign="top">
|
|
4141-FFFE</td>
|
|
</tr>
|
|
<tr>
|
|
<td valign="top"><a href="#CRTDEVDSP.TEXT"><b>TEXT</b></a></td>
|
|
<td valign="top">Text 'description'</td>
|
|
<td valign="top"><i>Character value</i>, <b><u>*BLANK</u></b></td>
|
|
<td valign="top">Optional</td>
|
|
</tr>
|
|
<tr>
|
|
<td valign="top"><a href="#CRTDEVDSP.DEPLOCNAME"><b>DEPLOCNAME</b></a></td>
|
|
<td valign="top">Dependent location name</td>
|
|
<td valign="top"><i>Communications name</i>, <b><u>*NONE</u></b></td>
|
|
<td valign="top">Optional</td>
|
|
</tr>
|
|
<tr>
|
|
<td valign="top" rowspan="3"><a href="#CRTDEVDSP.CHRID"><b>CHRID</b></a></td>
|
|
<td valign="top">Character identifier</td>
|
|
<td valign="top">Single values: *SYSVAL, <b><u>*KBDTYPE</u></b><br>Other values: <i>Element list</i></td>
|
|
<td valign="top" rowspan="3">Optional</td>
|
|
</tr>
|
|
<tr>
|
|
<td valign="top">Element 1: Graphic character set</td>
|
|
<td valign="top">
|
|
1-32767</td>
|
|
</tr>
|
|
<tr>
|
|
<td valign="top">Element 2: Code page</td>
|
|
<td valign="top">
|
|
1-32767</td>
|
|
</tr>
|
|
<tr>
|
|
<td valign="top"><a href="#CRTDEVDSP.PRTDEV"><b>PRTDEV</b></a></td>
|
|
<td valign="top">Print device</td>
|
|
<td valign="top"><i>Name</i>, <b><u>*SYSVAL</u></b></td>
|
|
<td valign="top">Optional</td>
|
|
</tr>
|
|
<tr>
|
|
<td valign="top" rowspan="3"><a href="#CRTDEVDSP.OUTQ"><b>OUTQ</b></a></td>
|
|
<td valign="top">Output queue</td>
|
|
<td valign="top">Single values: <b><u>*DEV</u></b><br>Other values: <i>Qualified object name</i></td>
|
|
<td valign="top" rowspan="3">Optional</td>
|
|
</tr>
|
|
<tr>
|
|
<td valign="top">Qualifier 1: Output queue</td>
|
|
<td valign="top"><i>Name</i></td>
|
|
</tr><tr>
|
|
<td valign="top">Qualifier 2: Library</td>
|
|
<td valign="top"><i>Name</i>, <b><u>*LIBL</u></b>, *CURLIB</td>
|
|
</tr><tr>
|
|
<td valign="top" rowspan="3"><a href="#CRTDEVDSP.PRTFILE"><b>PRTFILE</b></a></td>
|
|
<td valign="top">Printer file</td>
|
|
<td valign="top"><i>Qualified object name</i></td>
|
|
<td valign="top" rowspan="3">Optional</td>
|
|
</tr>
|
|
<tr>
|
|
<td valign="top">Qualifier 1: Printer file</td>
|
|
<td valign="top"><i>Name</i>, <b><u>QSYSPRT</u></b></td>
|
|
</tr><tr>
|
|
<td valign="top">Qualifier 2: Library</td>
|
|
<td valign="top"><i>Name</i>, <b><u>*LIBL</u></b>, *CURLIB</td>
|
|
</tr><tr>
|
|
<td valign="top" rowspan="3"><a href="#CRTDEVDSP.WSCST"><b>WSCST</b></a></td>
|
|
<td valign="top">Workstation customizing object</td>
|
|
<td valign="top">Single values: <b><u>*NONE</u></b><br>Other values: <i>Qualified object name</i></td>
|
|
<td valign="top" rowspan="3">Optional</td>
|
|
</tr>
|
|
<tr>
|
|
<td valign="top">Qualifier 1: Workstation customizing object</td>
|
|
<td valign="top"><i>Name</i></td>
|
|
</tr><tr>
|
|
<td valign="top">Qualifier 2: Library</td>
|
|
<td valign="top"><i>Name</i>, <b><u>*LIBL</u></b>, *CURLIB</td>
|
|
</tr><tr>
|
|
<td valign="top"><a href="#CRTDEVDSP.AUT"><b>AUT</b></a></td>
|
|
<td valign="top">Authority</td>
|
|
<td valign="top"><i>Name</i>, <b><u>*CHANGE</u></b>, *ALL, *USE, *EXCLUDE, *LIBCRTAUT</td>
|
|
<td valign="top">Optional</td>
|
|
</tr>
|
|
</table>
|
|
|
|
<table width="100%">
|
|
<tr><td align="right"><a href="#CRTDEVDSP.Top_Of_Page">Top</a></td></tr>
|
|
</table>
|
|
</div>
|
|
<div> <a name="CRTDEVDSP.DEVD"></a>
|
|
<h3>Device description (DEVD)</h3>
|
|
<p>Specifies the name of the device description.
|
|
</p>
|
|
<p>This is a required parameter.
|
|
</p>
|
|
</div>
|
|
<table width="100%">
|
|
<tr><td align="right"><a href="#CRTDEVDSP.Top_Of_Page">Top</a></td></tr>
|
|
</table>
|
|
<div> <a name="CRTDEVDSP.DEVCLS"></a>
|
|
<h3>Device class (DEVCLS)</h3>
|
|
<p>Specifies the device class for this display station or printer.
|
|
</p>
|
|
<dl>
|
|
<dt><b>*LCL</b></dt>
|
|
<dd>This device description is for a device connected to a local work station controller.
|
|
</dd>
|
|
<dt><b>*RMT</b></dt>
|
|
<dd>This device description is for a device connected to a remote work station controller.
|
|
</dd>
|
|
<dt><b>*VRT</b></dt>
|
|
<dd>This device description is for a virtual display station. Through a virtual display station, users can access (pass through to) their own system from a remote system. A virtual display station allows the remote system or a personal computer to emulate the interface of the user's own system.
|
|
</dd>
|
|
<dt><b>*SNPT</b></dt>
|
|
<dd>This device description is for a display station connected to an SNA pass-through advanced program-to-program communications (APPC) controller. SNA pass-through support allows the user to connect this display station with host logical unit (LU) types 0 through 3 applications.
|
|
</dd>
|
|
</dl>
|
|
<p>
|
|
<b>Note: </b>ASCII devices must be configured with a device class of *LCL (including ASCII devices attached with modems). To use ASCII display stations as virtual devices, create a virtual device description with the device type of the twinaxial display station that the ASCII display station emulates (for example, a virtual device of device type 3196 for an ASCII display station).
|
|
</p>
|
|
</div>
|
|
<table width="100%">
|
|
<tr><td align="right"><a href="#CRTDEVDSP.Top_Of_Page">Top</a></td></tr>
|
|
</table>
|
|
<div> <a name="CRTDEVDSP.TYPE"></a>
|
|
<h3>Device type (TYPE)</h3>
|
|
<p>Specifies the type of device which the description represents.
|
|
</p>
|
|
<ul>
|
|
<li>3179
|
|
</li>
|
|
<li>3180
|
|
</li>
|
|
<li>3196
|
|
</li>
|
|
<li>3197
|
|
</li>
|
|
<li>3277
|
|
</li>
|
|
<li>3278
|
|
</li>
|
|
<li>3279
|
|
</li>
|
|
<li>3476
|
|
</li>
|
|
<li>3477
|
|
</li>
|
|
<li>3486
|
|
</li>
|
|
<li>3487
|
|
</li>
|
|
<li>5150 (any display station attached by a TDLC link)
|
|
</li>
|
|
<li>5251
|
|
</li>
|
|
<li>5291
|
|
</li>
|
|
<li>5292
|
|
</li>
|
|
<li>5555 (Double-Byte Character Set)
|
|
</li>
|
|
<li>*NVT (Network Virtual Terminal)
|
|
</li>
|
|
</ul>
|
|
<p>The following type codes are valid for ASCII devices:
|
|
</p>
|
|
<ul>
|
|
<li>3101
|
|
</li>
|
|
<li>3151
|
|
</li>
|
|
<li>3161
|
|
</li>
|
|
<li>3162
|
|
</li>
|
|
<li>3163
|
|
</li>
|
|
<li>3164
|
|
</li>
|
|
<li>*CALC
|
|
</li>
|
|
</ul>
|
|
<p>
|
|
<b>Note: </b>Specifying *CALC allows port sharing for ASCII devices. ASCII port sharing allows different device types, using different physical parameters, to use the same port (at different times) without needing to manually reconfigure the port. If *CALC is specified for this parameter, the system automatically calculates the device types for displays attached to this port.
|
|
</p>
|
|
<p>More information on ASCII port sharing is in the Local Device Configuration book, SC41-5121 book or the ASCII Work Station Reference, SA41-3130.
|
|
</p>
|
|
<p>The following are trademarks of Data General, TeleVideo, DEC, Wyse and are valid for ASCII devices:
|
|
</p>
|
|
<dl>
|
|
<dt><b>TYPE</b></dt>
|
|
<dd><b> Description
|
|
</b></dd>
|
|
<dt><b>D220</b></dt>
|
|
<dd>Data General Dasher D220
|
|
</dd>
|
|
<dt><b>T910</b></dt>
|
|
<dd>TeleVideo 910
|
|
</dd>
|
|
<dt><b>T925</b></dt>
|
|
<dd>TeleVideo 925
|
|
</dd>
|
|
<dt><b>T955</b></dt>
|
|
<dd>TeleVideo 955
|
|
</dd>
|
|
<dt><b>V100</b></dt>
|
|
<dd>DEC VT-100
|
|
</dd>
|
|
<dt><b>V220</b></dt>
|
|
<dd>DEC VT-220
|
|
</dd>
|
|
<dt><b>W30</b></dt>
|
|
<dd>Wyse WY30
|
|
</dd>
|
|
<dt><b>W50</b></dt>
|
|
<dd>Wyse WY50
|
|
</dd>
|
|
<dt><b>W60</b></dt>
|
|
<dd>Wyse WY60
|
|
</dd>
|
|
</dl>
|
|
</div>
|
|
<table width="100%">
|
|
<tr><td align="right"><a href="#CRTDEVDSP.Top_Of_Page">Top</a></td></tr>
|
|
</table>
|
|
<div> <a name="CRTDEVDSP.MODEL"></a>
|
|
<h3>Device model (MODEL)</h3>
|
|
<p>Specifies the model number of the device for this description.
|
|
</p>
|
|
<p>This is a required parameter.
|
|
</p>
|
|
<p>The possible values for the device model for each device type are:
|
|
</p>
|
|
<dl>
|
|
<dt><b>TYPE</b></dt>
|
|
<dd><b> MODEL
|
|
</b></dd>
|
|
<dt><b>3179</b></dt>
|
|
<dd>2
|
|
</dd>
|
|
<dt><b>3180</b></dt>
|
|
<dd>2
|
|
</dd>
|
|
<dt><b>3196</b></dt>
|
|
<dd>A1, A2, B1, B2
|
|
</dd>
|
|
<dt><b>3197</b></dt>
|
|
<dd>C1, C2, D1, D2, W1, W2
|
|
</dd>
|
|
<dt><b>3277</b></dt>
|
|
<dd>0, *DHCF
|
|
</dd>
|
|
<dt><b>3278</b></dt>
|
|
<dd>0, 4, 5, *DHCF
|
|
</dd>
|
|
<dt><b>3279</b></dt>
|
|
<dd>0, 5, *DHCF
|
|
</dd>
|
|
<dt><b>3476</b></dt>
|
|
<dd>EA, EC
|
|
</dd>
|
|
<dt><b>3477</b></dt>
|
|
<dd>FA, FC, FD, FE, FG, FW
|
|
</dd>
|
|
<dt><b>3486</b></dt>
|
|
<dd>BA
|
|
</dd>
|
|
<dt><b>3487</b></dt>
|
|
<dd>HA, HC, HG, HW
|
|
</dd>
|
|
<dt><b>5150</b></dt>
|
|
<dd>1, 2, 3, 4, A1
|
|
</dd>
|
|
<dt><b>5251</b></dt>
|
|
<dd>11
|
|
</dd>
|
|
<dt><b>5291</b></dt>
|
|
<dd>1, 2
|
|
</dd>
|
|
<dt><b>5292</b></dt>
|
|
<dd>1, 2
|
|
</dd>
|
|
<dt><b>5555</b></dt>
|
|
<dd>B01, E01, C01, F01, G01, G02
|
|
</dd>
|
|
<dt><b>*NVT</b></dt>
|
|
<dd>0000
|
|
</dd>
|
|
</dl>
|
|
<p>For ASCII devices only:
|
|
</p>
|
|
<dl>
|
|
<dt><b>*ASCII</b></dt>
|
|
<dd>Specify this value if the model number cannot be easily determined for this display station. The system will assign a model number (if the device has a model number). The model number assigned by the system may not be the actual model number of your display station; see the following table to determine the model number which will be assigned by using *ASCII. It is recommended that you determine your display station's model number if at all possible, and enter that number.
|
|
<p>The possible choices are:
|
|
</p>
|
|
<dl>
|
|
<dt><b>TYPE</b></dt>
|
|
<dd><b> MODEL
|
|
</b></dd>
|
|
<dt><b>3101</b></dt>
|
|
<dd>23 (*ASCII)
|
|
</dd>
|
|
<dt><b>3151</b></dt>
|
|
<dd>11 (*ASCII), 31, 41
|
|
</dd>
|
|
<dt><b>3161</b></dt>
|
|
<dd>11 (*ASCII), 12
|
|
</dd>
|
|
<dt><b>3162</b></dt>
|
|
<dd>11 (*ASCII), 12, 31, 32
|
|
</dd>
|
|
<dt><b>3163</b></dt>
|
|
<dd>11 (*ASCII), 12
|
|
</dd>
|
|
<dt><b>3164</b></dt>
|
|
<dd>11 (*ASCII), 12
|
|
</dd>
|
|
<dt><b>*CALC</b></dt>
|
|
<dd>(*ASCII)
|
|
</dd>
|
|
</dl>
|
|
<p>The following devices are trademarks by Data General, TeleVideo, DEC, Wyse and must have a model number of *ASCII specified:
|
|
</p>
|
|
<dl>
|
|
<dt><b>TYPE</b></dt>
|
|
<dd><b> Description
|
|
</b></dd>
|
|
<dt><b>D220</b></dt>
|
|
<dd>Data General Dasher D220
|
|
</dd>
|
|
<dt><b>T910</b></dt>
|
|
<dd>TeleVideo 910
|
|
</dd>
|
|
<dt><b>T925</b></dt>
|
|
<dd>TeleVideo 925
|
|
</dd>
|
|
<dt><b>T955</b></dt>
|
|
<dd>TeleVideo 955
|
|
</dd>
|
|
<dt><b>V100</b></dt>
|
|
<dd>DEC VT-100
|
|
</dd>
|
|
<dt><b>V220</b></dt>
|
|
<dd>DEC VT-220
|
|
</dd>
|
|
<dt><b>W30</b></dt>
|
|
<dd>Wyse WY30
|
|
</dd>
|
|
<dt><b>W50</b></dt>
|
|
<dd>Wyse WY50
|
|
</dd>
|
|
<dt><b>W60</b></dt>
|
|
<dd>Wyse WY60
|
|
</dd>
|
|
</dl>
|
|
</dd>
|
|
</dl>
|
|
</div>
|
|
<table width="100%">
|
|
<tr><td align="right"><a href="#CRTDEVDSP.Top_Of_Page">Top</a></td></tr>
|
|
</table>
|
|
<div> <a name="CRTDEVDSP.EMLDEV"></a>
|
|
<h3>Emulated device (EMLDEV)</h3>
|
|
<p>Specifies the twinaxial device emulation to be used by an IBM 3151 or IBM 3162 display. The available emulations are 3196A2, which permits an 80-column display, and 3197D2, which permits a 132-column display.
|
|
</p>
|
|
<p>
|
|
<b>Note: </b>3197D2 emulation for an IBM 3151 model 31/41 requires the installation of a "cartridge for expansion" (part number 81X5575) in addition to the appropriate setting of this parameter.
|
|
</p>
|
|
<dl>
|
|
<dt><b><u>*TYPE</u></b></dt>
|
|
<dd>The default value for this parameter is 3196A2.
|
|
</dd>
|
|
<dt><b>3196A2</b></dt>
|
|
<dd>An 80-column display is used.
|
|
</dd>
|
|
<dt><b>3197D2</b></dt>
|
|
<dd>A 132-column display is used.
|
|
</dd>
|
|
</dl>
|
|
</div>
|
|
<table width="100%">
|
|
<tr><td align="right"><a href="#CRTDEVDSP.Top_Of_Page">Top</a></td></tr>
|
|
</table>
|
|
<div> <a name="CRTDEVDSP.PORT"></a>
|
|
<h3>Port number (PORT)</h3>
|
|
<p>Specifies the port number for local devices.
|
|
</p>
|
|
<p>For twinaxial devices: Possible values range from 0 through 7.
|
|
</p>
|
|
<p>For ASCII devices: Possible values range from 0 through 17 and indicate the port on the ASCII work station controller to which this device is attached. Without the 12-port expansion feature, ports 0 through 5 are valid. With the 12-port expansion feature, ports 6 through 17 are added.
|
|
</p>
|
|
</div>
|
|
<table width="100%">
|
|
<tr><td align="right"><a href="#CRTDEVDSP.Top_Of_Page">Top</a></td></tr>
|
|
</table>
|
|
<div> <a name="CRTDEVDSP.SWTSET"></a>
|
|
<h3>Switch setting (SWTSET)</h3>
|
|
<p>Specifies the switch setting for local twinaxial devices.
|
|
</p>
|
|
<p>Valid values range from 0 to 6.
|
|
</p>
|
|
</div>
|
|
<table width="100%">
|
|
<tr><td align="right"><a href="#CRTDEVDSP.Top_Of_Page">Top</a></td></tr>
|
|
</table>
|
|
<div> <a name="CRTDEVDSP.SHRSSNNBR"></a>
|
|
<h3>Shared session number (SHRSSNNBR)</h3>
|
|
<p>Specifies the shared session number for a twinaxial display station. This parameter is valid only for 3486 and 3487 configured device types.
|
|
</p>
|
|
<p>
|
|
<b>Note: </b>Displays that share session addresses can be attached only to the 2661, 6050, 9146, or the 915A local work station controllers, or to the 5494 remote work station controller.
|
|
</p>
|
|
<dl>
|
|
<dt><b><u>0</u></b></dt>
|
|
<dd>The shared session number is 0.
|
|
</dd>
|
|
<dt><b>1</b></dt>
|
|
<dd>The shared session number is 1.
|
|
</dd>
|
|
<dt><b>2</b></dt>
|
|
<dd>The shared session number is 2.
|
|
</dd>
|
|
<dt><b>3</b></dt>
|
|
<dd>The shared session number is 3.
|
|
</dd>
|
|
</dl>
|
|
</div>
|
|
<table width="100%">
|
|
<tr><td align="right"><a href="#CRTDEVDSP.Top_Of_Page">Top</a></td></tr>
|
|
</table>
|
|
<div> <a name="CRTDEVDSP.LOCADR"></a>
|
|
<h3>Local location address (LOCADR)</h3>
|
|
<p>Specifies the local location address for this device.
|
|
</p>
|
|
<p>The possible values range from 00 to FE. The type of controller to which the device is being attached determines which values are valid.
|
|
</p>
|
|
<dl>
|
|
<dt><b>Controller</b></dt>
|
|
<dd><b> Valid Values
|
|
</b></dd>
|
|
<dt><b>5251</b></dt>
|
|
<dd>00, 02-09
|
|
</dd>
|
|
<dt><b>5294</b></dt>
|
|
<dd>00-1B
|
|
</dd>
|
|
<dt><b>5394</b></dt>
|
|
<dd>00-14
|
|
</dd>
|
|
<dt><b>5494</b></dt>
|
|
<dd>00-37
|
|
</dd>
|
|
<dt><b>3174</b></dt>
|
|
<dd>02-41
|
|
</dd>
|
|
<dt><b>3274</b></dt>
|
|
<dd>02-41
|
|
</dd>
|
|
<dt><b>SNA Host</b></dt>
|
|
<dd>01-FE
|
|
</dd>
|
|
<dt><b>4701</b></dt>
|
|
<dd>02-FE
|
|
</dd>
|
|
<dt><b>4702</b></dt>
|
|
<dd>02-FE
|
|
</dd>
|
|
<dt><b>4680</b></dt>
|
|
<dd>02-54
|
|
</dd>
|
|
<dt><b>4684</b></dt>
|
|
<dd>02-FE
|
|
</dd>
|
|
<dt><b>FBSS</b></dt>
|
|
<dd>02-FE
|
|
</dd>
|
|
</dl>
|
|
</div>
|
|
<table width="100%">
|
|
<tr><td align="right"><a href="#CRTDEVDSP.Top_Of_Page">Top</a></td></tr>
|
|
</table>
|
|
<div> <a name="CRTDEVDSP.EMLASCII"></a>
|
|
<h3>Emulating ASCII device (EMLASCII)</h3>
|
|
<p>Specifies, for ASCII devices, whether the device being configured is emulating a supported ASCII device type (TYPE parameter). When an ASCII device is configured, choices for the following parameters are restricted to the valid range for that device:
|
|
</p>
|
|
<ul>
|
|
<li>ATTACH (Physical attachment)
|
|
</li>
|
|
<li>LINESPEED (Line speed)
|
|
</li>
|
|
<li>WORDLEN (Word length)
|
|
</li>
|
|
<li>PARITY (Type of parity)
|
|
</li>
|
|
<li>STOPBITS (Stop bits)
|
|
</li>
|
|
</ul>
|
|
<p>For ASCII devices emulating supported ASCII device types, these restrictions may not be applicable (the emulating device might have a wider range of choices for these parameters than the emulated ASCII device does). When EMLASCII(*YES) is specified, these parameter restrictions are not enforced; the user is allowed to enter the full range of values for these parameters, but also is responsible for verifying that the values selected are valid for the device being configured.
|
|
</p>
|
|
<dl>
|
|
<dt><b><u>*NO</u></b></dt>
|
|
<dd>Specifies that the device being configured is one of the supported ASCII device types <b>Device type (TYPE)</b> parameter, and that the device-specific restrictions for the physical attachment, line speed, word length, type of parity, and stop bits parameters are to be enforced.
|
|
</dd>
|
|
<dt><b>*YES</b></dt>
|
|
<dd>Specifies that the device being configured is emulating one of the supported ASCII device types (TYPE parameter), and that the device-specific restrictions for the physical attachment, line speed, word length, type of parity, and stop bits parameters are not enforced.
|
|
</dd>
|
|
</dl>
|
|
</div>
|
|
<table width="100%">
|
|
<tr><td align="right"><a href="#CRTDEVDSP.Top_Of_Page">Top</a></td></tr>
|
|
</table>
|
|
<div> <a name="CRTDEVDSP.ATTACH"></a>
|
|
<h3>Physical attachment (ATTACH)</h3>
|
|
<p>Specifies, for ASCII display stations, the physical attachment of the display station to the ASCII work station controller.
|
|
</p>
|
|
<dl>
|
|
<dt><b>*EIA422</b></dt>
|
|
<dd>The EIA-422 attachment (valid only for models 3101, 3151, 3161, 3162, 3163, and 3164) is used.
|
|
</dd>
|
|
<dt><b>*DIRECT</b></dt>
|
|
<dd>Specifies EIA-232 Direct attachment.
|
|
</dd>
|
|
<dt><b>*MODEM</b></dt>
|
|
<dd>Specifies EIA-232 modem attachment.
|
|
</dd>
|
|
<dt><b>*PTT</b></dt>
|
|
<dd>Specifies Post Telephone and Telegraph (PTT) attachment.
|
|
</dd>
|
|
<dt><b>*WIRE3</b></dt>
|
|
<dd>Specifies EIA-232 3-wire attachment.
|
|
</dd>
|
|
<dt><b>*WIRE4</b></dt>
|
|
<dd>Specifies EIA-232 4-wire attachment.
|
|
</dd>
|
|
</dl>
|
|
</div>
|
|
<table width="100%">
|
|
<tr><td align="right"><a href="#CRTDEVDSP.Top_Of_Page">Top</a></td></tr>
|
|
</table>
|
|
<div> <a name="CRTDEVDSP.ONLINE"></a>
|
|
<h3>Online at IPL (ONLINE)</h3>
|
|
<p>Specifies whether this object is automatically varied on at initial program load (IPL).
|
|
</p>
|
|
<dl>
|
|
<dt><b><u>*YES</u></b></dt>
|
|
<dd>This device is varied on automatically at IPL.
|
|
</dd>
|
|
<dt><b>*NO</b></dt>
|
|
<dd>This device is not varied on automatically at IPL.
|
|
</dd>
|
|
</dl>
|
|
<p>
|
|
<b>Note: </b>This parameter is ignored when specified on the console or alternate console description.
|
|
</p>
|
|
</div>
|
|
<table width="100%">
|
|
<tr><td align="right"><a href="#CRTDEVDSP.Top_Of_Page">Top</a></td></tr>
|
|
</table>
|
|
<div> <a name="CRTDEVDSP.CTL"></a>
|
|
<h3>Attached controller (CTL)</h3>
|
|
<p>Specifies the name of the controller description to which this device is attached.
|
|
</p>
|
|
<p>
|
|
<b>Note: </b>To use this device for communicating with a remote location that resides on the same system as the local location, specify a controller description that was created with LINKTYPE (*LOCAL) specified.
|
|
</p>
|
|
</div>
|
|
<table width="100%">
|
|
<tr><td align="right"><a href="#CRTDEVDSP.Top_Of_Page">Top</a></td></tr>
|
|
</table>
|
|
<div> <a name="CRTDEVDSP.KBDTYPE"></a>
|
|
<h3>Keyboard language type (KBDTYPE)</h3>
|
|
<p>Specifies the country keyboard language identifier for this display station.
|
|
</p>
|
|
<p><b>NOTES:</b>
|
|
</p>
|
|
<ol>
|
|
<li>When DEVCLS(*RMT) is specified and when TYPE(3277), TYPE(3278), or TYPE(3279) is specified, the following values can be specified: *SYSVAL, AGI, ALI, BGB, BLI, CAI, CSB, DMI, FNI, FAI, HNB, IRB, ITI, JPB, MKB, NWI, PLB, PRI, RMB, RUB, SKB, SPI, SQB, SSI, SWI, TRB, USB, USI, or YGI. Otherwise, this parameter is not valid when DEVCLS(*RMT) is specified.
|
|
</li>
|
|
<li>When TYPE(3486) or TYPE(3487) is specified, the following values can be specified: *SYSVAL, AGB, AGI, ALI, BGB, BLI, CAB, CAI, CLB, CSB, DMB, DMI, FAB, FAI, FNB, FNI, GNB (or GKB), HNB, ICB, ICI, IRB, ITB, ITI, JPB, KAB, MKB, NCB, NEB, NEI, NWB, PLB, PRB, PRI, RMB, RUB, SFI, SGI, SKB, SPB, SPI, SQB, SSB, SSI, SWB, SWI, TKB, TRB, UKB, UKI, USB, USI, or YGI.
|
|
</li>
|
|
<li>This parameter is optional for the combination of DEVCLS(*LCL) and TYPE(5150).
|
|
</li>
|
|
</ol>
|
|
<dl>
|
|
<dt><b><u>*SYSVAL</u></b></dt>
|
|
<dd>Instructs the system to use the QKBDTYPE system value.
|
|
</dd>
|
|
<dt><b><i>keyboard language-type</i></b></dt>
|
|
<dd>Specify the 3-character country identifier (used for EBCDIC and ASCII) for this display station.
|
|
</dd>
|
|
</dl>
|
|
<p>The following two tables can be used to confirm the appropriate value for this parameter, or to determine which ASCII display devices can be used with a specified language.
|
|
</p>
|
|
<ul>
|
|
<li>The keyboard mapping table shows valid country identifiers, the language represented by each identifier, and the ASCII device groups, if applicable, for each language.
|
|
</li>
|
|
<li>The ASCII displays and device groups table shows the valid display devices and their associated ASCII device groups.
|
|
</li>
|
|
</ul>
|
|
<p>For example, assume a user wants to create a 3101 display device. The ASCII displays and device groups table shows that a 3101 display supports ASCII device group A. The Keyboard Mapping table shows that the valid language identifiers that can be used with device group A include AGB, AGI, CAB, CAI, FAB, FAI, ITB, ITI, UKB, UKI, USB, and USI.
|
|
</p>
|
|
<p>The following keyboards can be specified by ASCII displays only if a customizing object is also used: ALI, BGB, CSB, ESB, HNB, LTB, LVB, MKB, PKB, PLB, RMB, RUB, SKB, SQB, TRB, UAB, and YGI.
|
|
</p>
|
|
<dl>
|
|
<dt><b>Identifier</b></dt>
|
|
<dd><b> Language(Country) - ASCII Device Groups
|
|
</b></dd>
|
|
<dt><b>ALI</b></dt>
|
|
<dd>Albania
|
|
</dd>
|
|
<dt><b>ALM</b></dt>
|
|
<dd>Albania Euro Currency
|
|
</dd>
|
|
<dt><b>CLB</b></dt>
|
|
<dd>Arabic X/Basic - D*
|
|
</dd>
|
|
<dt><b>CLE</b></dt>
|
|
<dd>Arabic X/Basic Euro Currency
|
|
</dd>
|
|
<dt><b>AGB</b></dt>
|
|
<dd>Austria/Germany - A, B
|
|
</dd>
|
|
<dt><b>AGE</b></dt>
|
|
<dd>Austria/Germany Euro Currency
|
|
</dd>
|
|
<dt><b>AGI</b></dt>
|
|
<dd>Austria/Germany Multinational - A, B
|
|
</dd>
|
|
<dt><b>AGM</b></dt>
|
|
<dd>Austria/Germany Multinational Euro Currency
|
|
</dd>
|
|
<dt><b>BLI</b></dt>
|
|
<dd>Belgium Multinational - B
|
|
</dd>
|
|
<dt><b>BLM</b></dt>
|
|
<dd>Belgium Multinational Euro Currency
|
|
</dd>
|
|
<dt><b>BRB</b></dt>
|
|
<dd>Brazilian Portuguese
|
|
</dd>
|
|
<dt><b>BRE</b></dt>
|
|
<dd>Brazilian Portuguese Euro Currency
|
|
</dd>
|
|
<dt><b>BGB</b></dt>
|
|
<dd>Bulgaria
|
|
</dd>
|
|
<dt><b>BGE</b></dt>
|
|
<dd>Bulgaria Euro Currency
|
|
</dd>
|
|
<dt><b>CAB</b></dt>
|
|
<dd>Canadian French - A, B
|
|
</dd>
|
|
<dt><b>CAE</b></dt>
|
|
<dd>Canadian French Euro Currency
|
|
</dd>
|
|
<dt><b>CAI</b></dt>
|
|
<dd>Canadian French Multinational - A, B
|
|
</dd>
|
|
<dt><b>CAM</b></dt>
|
|
<dd>Canadian French Multinational Euro Currency
|
|
</dd>
|
|
<dt><b>SPB</b></dt>
|
|
<dd>Catalan
|
|
</dd>
|
|
<dt><b>RCB</b></dt>
|
|
<dd>Chinese (Simplified)
|
|
</dd>
|
|
<dt><b>TAB</b></dt>
|
|
<dd>Chinese (Traditional)
|
|
</dd>
|
|
<dt><b>YGI</b></dt>
|
|
<dd>Croatia
|
|
</dd>
|
|
<dt><b>YGM</b></dt>
|
|
<dd>Croatia Euro Currency
|
|
</dd>
|
|
<dt><b>CYB</b></dt>
|
|
<dd>Cyrillic
|
|
</dd>
|
|
<dt><b>CSB</b></dt>
|
|
<dd>Czech Republic
|
|
</dd>
|
|
<dt><b>CSE</b></dt>
|
|
<dd>Czech Republic Euro Currency
|
|
</dd>
|
|
<dt><b>DMB</b></dt>
|
|
<dd>Denmark - B
|
|
</dd>
|
|
<dt><b>DME</b></dt>
|
|
<dd>Denmark Euro Currency
|
|
</dd>
|
|
<dt><b>DMI</b></dt>
|
|
<dd>Denmark Multinational - B
|
|
</dd>
|
|
<dt><b>DMM</b></dt>
|
|
<dd>Denmark Multinational Euro Currency
|
|
</dd>
|
|
<dt><b>ESB</b></dt>
|
|
<dd>Estonia
|
|
</dd>
|
|
<dt><b>FNB</b></dt>
|
|
<dd>Finland/Sweden - B
|
|
</dd>
|
|
<dt><b>FNE</b></dt>
|
|
<dd>Finland/Sweden Euro Currency
|
|
</dd>
|
|
<dt><b>FNI</b></dt>
|
|
<dd>Finland/Sweden Multinational - B
|
|
</dd>
|
|
<dt><b>FNM</b></dt>
|
|
<dd>Finland/Sweden Multinational Euro Currency
|
|
</dd>
|
|
<dt><b>FAB</b></dt>
|
|
<dd>France (Azerty) - A, B
|
|
</dd>
|
|
<dt><b>FAE</b></dt>
|
|
<dd>France (Azerty) Euro Currency
|
|
</dd>
|
|
<dt><b>FAI</b></dt>
|
|
<dd>France (Azerty) Multinational - A, B
|
|
</dd>
|
|
<dt><b>FAM</b></dt>
|
|
<dd>France (Azerty) Multinational Euro Currency
|
|
</dd>
|
|
<dt><b>FQB</b></dt>
|
|
<dd>France (Qwerty)
|
|
</dd>
|
|
<dt><b>FQI</b></dt>
|
|
<dd>France (Qwerty) International
|
|
</dd>
|
|
<dt><b>GNB</b></dt>
|
|
<dd>Greek (see note)
|
|
</dd>
|
|
<dt><b>GNE</b></dt>
|
|
<dd>Greek Euro Currency
|
|
</dd>
|
|
<dt><b>NCB</b></dt>
|
|
<dd>Hebrew - D*
|
|
</dd>
|
|
<dt><b>NCE</b></dt>
|
|
<dd>Hebrew Euro Currency
|
|
</dd>
|
|
<dt><b>HIB</b></dt>
|
|
<dd>Hindi
|
|
</dd>
|
|
<dt><b>HNB</b></dt>
|
|
<dd>Hungary
|
|
</dd>
|
|
<dt><b>HNE</b></dt>
|
|
<dd>Hungary Euro Currency
|
|
</dd>
|
|
<dt><b>ICB</b></dt>
|
|
<dd>Iceland
|
|
</dd>
|
|
<dt><b>ICE</b></dt>
|
|
<dd>Iceland Euro Currency
|
|
</dd>
|
|
<dt><b>ICI</b></dt>
|
|
<dd>Iceland Multinational
|
|
</dd>
|
|
<dt><b>ICM</b></dt>
|
|
<dd>Iceland Multinational Euro Currency
|
|
</dd>
|
|
<dt><b>INB</b></dt>
|
|
<dd>International
|
|
</dd>
|
|
<dt><b>INI</b></dt>
|
|
<dd>International Multinational
|
|
</dd>
|
|
<dt><b>IRB</b></dt>
|
|
<dd>Iran (Farsi)
|
|
</dd>
|
|
<dt><b>ITB</b></dt>
|
|
<dd>Italy - A, B
|
|
</dd>
|
|
<dt><b>ITE</b></dt>
|
|
<dd>Italy Euro Currency
|
|
</dd>
|
|
<dt><b>ITI</b></dt>
|
|
<dd>Italy Multinational - A, B
|
|
</dd>
|
|
<dt><b>ITM</b></dt>
|
|
<dd>Italy Multinational Euro Currency
|
|
</dd>
|
|
<dt><b>JEB</b></dt>
|
|
<dd>Japan English
|
|
</dd>
|
|
<dt><b>JEI</b></dt>
|
|
<dd>Japan English Multinational
|
|
</dd>
|
|
<dt><b>JKB</b></dt>
|
|
<dd>Japan Kanji
|
|
</dd>
|
|
<dt><b>JPB</b></dt>
|
|
<dd>Japan Latin Extended
|
|
</dd>
|
|
<dt><b>JPE</b></dt>
|
|
<dd>Japan Latin Extended Euro Currency
|
|
</dd>
|
|
<dt><b>JUB</b></dt>
|
|
<dd>Japan U.S. Basic
|
|
</dd>
|
|
<dt><b>KAB</b></dt>
|
|
<dd>Japan Katakana
|
|
</dd>
|
|
<dt><b>KOB</b></dt>
|
|
<dd>Korea
|
|
</dd>
|
|
<dt><b>LAB</b></dt>
|
|
<dd>Lao People's Democratic Republic
|
|
</dd>
|
|
<dt><b>LAE</b></dt>
|
|
<dd>Lao People's Democratic Republic Euro Currency
|
|
</dd>
|
|
<dt><b>ROB</b></dt>
|
|
<dd>Latin-2/ROECE
|
|
</dd>
|
|
<dt><b>ROE</b></dt>
|
|
<dd>Latin-2/ROECE Euro Currency
|
|
</dd>
|
|
<dt><b>LVB</b></dt>
|
|
<dd>Latvia
|
|
</dd>
|
|
<dt><b>LTB</b></dt>
|
|
<dd>Lithuania
|
|
</dd>
|
|
<dt><b>MKB</b></dt>
|
|
<dd>FYR Macedonia (Former Yugoslav Republic)
|
|
</dd>
|
|
<dt><b>MKE</b></dt>
|
|
<dd>FYR Macedonia Euro Currency
|
|
</dd>
|
|
<dt><b>NEB</b></dt>
|
|
<dd>Netherlands
|
|
</dd>
|
|
<dt><b>NEE</b></dt>
|
|
<dd>Netherlands Euro Currency
|
|
</dd>
|
|
<dt><b>NEI</b></dt>
|
|
<dd>Netherlands Multinational
|
|
</dd>
|
|
<dt><b>NEM</b></dt>
|
|
<dd>Netherlands Multinational Euro Currency
|
|
</dd>
|
|
<dt><b>NWB</b></dt>
|
|
<dd>Norway - B
|
|
</dd>
|
|
<dt><b>NWE</b></dt>
|
|
<dd>Norway Euro Currency
|
|
</dd>
|
|
<dt><b>NWI</b></dt>
|
|
<dd>Norway Multinational - B
|
|
</dd>
|
|
<dt><b>NWM</b></dt>
|
|
<dd>Norway Multinational Euro Currency
|
|
</dd>
|
|
<dt><b>PLB</b></dt>
|
|
<dd>Poland
|
|
</dd>
|
|
<dt><b>PLE</b></dt>
|
|
<dd>Poland Euro Currency
|
|
</dd>
|
|
<dt><b>PRB</b></dt>
|
|
<dd>Portugal - B
|
|
</dd>
|
|
<dt><b>PRE</b></dt>
|
|
<dd>Portugal Euro Currency
|
|
</dd>
|
|
<dt><b>PRI</b></dt>
|
|
<dd>Portugal Multinational - B
|
|
</dd>
|
|
<dt><b>PRM</b></dt>
|
|
<dd>Portugal Multinational Euro Currency
|
|
</dd>
|
|
<dt><b>RMB</b></dt>
|
|
<dd>Romania
|
|
</dd>
|
|
<dt><b>RME</b></dt>
|
|
<dd>Romania Euro Currency
|
|
</dd>
|
|
<dt><b>RUB</b></dt>
|
|
<dd>Russia
|
|
</dd>
|
|
<dt><b>RUE</b></dt>
|
|
<dd>Russia Euro Currency
|
|
</dd>
|
|
<dt><b>SQB</b></dt>
|
|
<dd>Serbia (Cyrillic)
|
|
</dd>
|
|
<dt><b>SQE</b></dt>
|
|
<dd>Serbia (Cyrillic) Euro Currency
|
|
</dd>
|
|
<dt><b>YGI</b></dt>
|
|
<dd>Serbia (Latin)
|
|
</dd>
|
|
<dt><b>YGM</b></dt>
|
|
<dd>Serbia (Latin) Euro Currency
|
|
</dd>
|
|
<dt><b>SKB</b></dt>
|
|
<dd>Slovakia
|
|
</dd>
|
|
<dt><b>SKE</b></dt>
|
|
<dd>Slovakia Euro Currency
|
|
</dd>
|
|
<dt><b>YGI</b></dt>
|
|
<dd>Slovenia
|
|
</dd>
|
|
<dt><b>YGM</b></dt>
|
|
<dd>Slovenia Euro Currency
|
|
</dd>
|
|
<dt><b>SPB</b></dt>
|
|
<dd>Spain - B
|
|
</dd>
|
|
<dt><b>SPE</b></dt>
|
|
<dd>Spain Euro Currency
|
|
</dd>
|
|
<dt><b>SPI</b></dt>
|
|
<dd>Spain Multinational - B
|
|
</dd>
|
|
<dt><b>SPM</b></dt>
|
|
<dd>Spain Multinational Euro Currency
|
|
</dd>
|
|
<dt><b>SSB</b></dt>
|
|
<dd>Spanish Speaking - B
|
|
</dd>
|
|
<dt><b>SSE</b></dt>
|
|
<dd>Spanish Speaking Euro Currency
|
|
</dd>
|
|
<dt><b>SSI</b></dt>
|
|
<dd>Spanish Speaking Multinational - B
|
|
</dd>
|
|
<dt><b>SSM</b></dt>
|
|
<dd>Spanish Speaking Multinational Euro Currency
|
|
</dd>
|
|
<dt><b>SWB</b></dt>
|
|
<dd>Sweden - B
|
|
</dd>
|
|
<dt><b>SWE</b></dt>
|
|
<dd>Sweden Euro Currency
|
|
</dd>
|
|
<dt><b>SWI</b></dt>
|
|
<dd>Sweden Multinational - B
|
|
</dd>
|
|
<dt><b>SWM</b></dt>
|
|
<dd>Sweden Multinational Euro Currency
|
|
</dd>
|
|
<dt><b>SFI</b></dt>
|
|
<dd>Switzerland/France Multinational - B
|
|
</dd>
|
|
<dt><b>SFM</b></dt>
|
|
<dd>Switzerland/France Multinational Euro Currency
|
|
</dd>
|
|
<dt><b>SGI</b></dt>
|
|
<dd>Switzerland/Germany Multinational - B
|
|
</dd>
|
|
<dt><b>THB</b></dt>
|
|
<dd>Thailand
|
|
</dd>
|
|
<dt><b>THE</b></dt>
|
|
<dd>Thailand Euro Currency
|
|
</dd>
|
|
<dt><b>TKB</b></dt>
|
|
<dd>Turkey (Qwerty)
|
|
</dd>
|
|
<dt><b>TKE</b></dt>
|
|
<dd>Turkey (Qwerty) Euro Currency
|
|
</dd>
|
|
<dt><b>TRB</b></dt>
|
|
<dd>Turkey (F)
|
|
</dd>
|
|
<dt><b>TRE</b></dt>
|
|
<dd>Turkey (F) Euro Currency
|
|
</dd>
|
|
<dt><b>UAB</b></dt>
|
|
<dd>Ukraine
|
|
</dd>
|
|
<dt><b>UAE</b></dt>
|
|
<dd>Ukraine Euro Currency
|
|
</dd>
|
|
<dt><b>UKB</b></dt>
|
|
<dd>United Kingdom - A, B
|
|
</dd>
|
|
<dt><b>UKE</b></dt>
|
|
<dd>United Kingdom Euro Currency
|
|
</dd>
|
|
<dt><b>UKI</b></dt>
|
|
<dd>United Kingdom Multinational - A, B
|
|
</dd>
|
|
<dt><b>UKM</b></dt>
|
|
<dd>United Kingdom Multinational Euro Currency
|
|
</dd>
|
|
<dt><b>USB</b></dt>
|
|
<dd>United States/Canada - A, B, C
|
|
</dd>
|
|
<dt><b>USE</b></dt>
|
|
<dd>United States/Canada Euro Currency
|
|
</dd>
|
|
<dt><b>USI</b></dt>
|
|
<dd>United States/Canada Multinational - A, B, C
|
|
</dd>
|
|
<dt><b>USM</b></dt>
|
|
<dd>United States/Canada Multinational Euro Currency
|
|
</dd>
|
|
<dt><b>PKB</b></dt>
|
|
<dd>Urdu
|
|
</dd>
|
|
<dt><b>PKE</b></dt>
|
|
<dd>Urdu Euro Currency
|
|
</dd>
|
|
<dt><b>VNB</b></dt>
|
|
<dd>Vietnam
|
|
</dd>
|
|
<dt><b>VNE</b></dt>
|
|
<dd>Vietnam Euro Currency
|
|
</dd>
|
|
<dt><b>YGI</b></dt>
|
|
<dd>Languages of the former Yugoslavia
|
|
</dd>
|
|
<dt><b>YGM</b></dt>
|
|
<dd>Languages of the former Yugoslavia Euro Currency
|
|
</dd>
|
|
</dl>
|
|
<p>
|
|
<b>Note: </b>The GNB code is the current identifier for Greece. The GKB code was used prior to V2R1, and continues to be supported, but provides fewer characters than the recommended GNB code.
|
|
</p>
|
|
<p><b>ASCII Displays and Devices Groups</b>
|
|
</p>
|
|
<dl>
|
|
<dt><b>Display</b></dt>
|
|
<dd><b> ASCII Device Group
|
|
</b></dd>
|
|
<dt><b>3101</b></dt>
|
|
<dd>A
|
|
</dd>
|
|
<dt><b>3151</b></dt>
|
|
<dd>B
|
|
</dd>
|
|
<dt><b>3161</b></dt>
|
|
<dd>B
|
|
</dd>
|
|
<dt><b>3162</b></dt>
|
|
<dd>B
|
|
</dd>
|
|
<dt><b>3163</b></dt>
|
|
<dd>B
|
|
</dd>
|
|
<dt><b>3164</b></dt>
|
|
<dd>B
|
|
</dd>
|
|
</dl>
|
|
<p>The following devices are trademarks by TeleVideo, DEC, or Wyse, and must only specify languages in ASCII Device Group C or D:
|
|
</p>
|
|
<dl>
|
|
<dt><b>Display</b></dt>
|
|
<dd><b> Description
|
|
</b></dd>
|
|
<dt><b>D220</b></dt>
|
|
<dd>Data General Dasher D220
|
|
</dd>
|
|
<dt><b>T910</b></dt>
|
|
<dd>TeleVideo 910
|
|
</dd>
|
|
<dt><b>T925</b></dt>
|
|
<dd>TeleVideo 925
|
|
</dd>
|
|
<dt><b>T955</b></dt>
|
|
<dd>TeleVideo 955
|
|
</dd>
|
|
<dt><b>V100</b></dt>
|
|
<dd>DEC VT-100
|
|
</dd>
|
|
<dt><b>V220</b></dt>
|
|
<dd>DEC VT-220 (supports ASCII Device Group D and C)
|
|
</dd>
|
|
<dt><b>W30</b></dt>
|
|
<dd>Wyse WY30
|
|
</dd>
|
|
<dt><b>W50</b></dt>
|
|
<dd>Wyse WY50
|
|
</dd>
|
|
<dt><b>W60</b></dt>
|
|
<dd>Wyse WY60
|
|
</dd>
|
|
</dl>
|
|
</div>
|
|
<table width="100%">
|
|
<tr><td align="right"><a href="#CRTDEVDSP.Top_Of_Page">Top</a></td></tr>
|
|
</table>
|
|
<div> <a name="CRTDEVDSP.DROP"></a>
|
|
<h3>Drop line at signoff (DROP)</h3>
|
|
<p>Specifies, for remote display stations, whether the line is disconnected by the system when all devices on the line are no longer in use.
|
|
</p>
|
|
<p>The value specified in the device description can be overridden by a user signing off at the device if the user specifies the <b>Drop line at signoff (DROP)</b> parameter on the SIGNOFF command.
|
|
</p>
|
|
<dl>
|
|
<dt><b><u>*YES</u></b></dt>
|
|
<dd>The switched line to the controller to which this device is attached is disconnected when this device and all other attached devices are no longer in use.
|
|
</dd>
|
|
<dt><b>*NO</b></dt>
|
|
<dd>The switched line is not disconnected from the controller when all of its attached devices are no longer in use.
|
|
</dd>
|
|
</dl>
|
|
</div>
|
|
<table width="100%">
|
|
<tr><td align="right"><a href="#CRTDEVDSP.Top_Of_Page">Top</a></td></tr>
|
|
</table>
|
|
<div> <a name="CRTDEVDSP.ALWBLN"></a>
|
|
<h3>Allow blinking cursor (ALWBLN)</h3>
|
|
<p>Specifies whether the (program controlled) blinking cursor is suppressed.
|
|
</p>
|
|
<p>
|
|
<b>Note: </b>The value specified for this parameter can be overridden by display stations that have a keyboard setup capability that allows the blinking cursor attribute to be changed.
|
|
</p>
|
|
<dl>
|
|
<dt><b><u>*YES</u></b></dt>
|
|
<dd>Allows the cursor to blink for the 3179, 3180, 3196, 3197, 3476, 3477, 3486, 3487, 5251, 5291, and 5292 display devices.
|
|
</dd>
|
|
<dt><b>*NO</b></dt>
|
|
<dd>The blinking cursor is suppressed.
|
|
</dd>
|
|
</dl>
|
|
</div>
|
|
<table width="100%">
|
|
<tr><td align="right"><a href="#CRTDEVDSP.Top_Of_Page">Top</a></td></tr>
|
|
</table>
|
|
<div> <a name="CRTDEVDSP.AUXDEV"></a>
|
|
<h3>Auxiliary device (AUXDEV)</h3>
|
|
<p>Specifies the device type and address of an additional device (if any) that is attached to the IEEE-488 port on the 5292 Model 2 device. Up to 31 plotters can be attached to the same IEEE-488 AUXDEV port on the 5292 Model 2, but at different IEEE-488 addresses. The valid additional device types are: 7371 (IBM 7371 Plotter), the 7372 (IBM 7372 Plotter), the 6180 (IBM 6180 Plotter), the 6182 (IBM 6182 Plotter), the 6184 (IBM 6184 Plotter), the 6185 (IBM 6185 Plotter), the 6186M1 (IBM 6186M1 Plotter), and the 6186M2 (IBM 6186M2 Plotter). The valid additional device address is a number from 1 to 31.
|
|
</p>
|
|
<p>You can enter multiple values for this parameter.
|
|
</p>
|
|
</div>
|
|
<table width="100%">
|
|
<tr><td align="right"><a href="#CRTDEVDSP.Top_Of_Page">Top</a></td></tr>
|
|
</table>
|
|
<div> <a name="CRTDEVDSP.PRINTER"></a>
|
|
<h3>Printer (PRINTER)</h3>
|
|
<p>Specifies, for a remote display station, the device name of the printer associated with the display device. The device description of the work station printer named in this parameter must have already been created and must currently exist on the system. Both the printer and the display device must be attached to the same controller.
|
|
</p>
|
|
</div>
|
|
<table width="100%">
|
|
<tr><td align="right"><a href="#CRTDEVDSP.Top_Of_Page">Top</a></td></tr>
|
|
</table>
|
|
<div> <a name="CRTDEVDSP.MAXLENRU"></a>
|
|
<h3>Maximum length of request unit (MAXLENRU)</h3>
|
|
<p>Specifies, for remote display stations and printers, the maximum request unit (RU) length (in bytes) allowed.
|
|
</p>
|
|
<dl>
|
|
<dt><b><u>*CALC</u></b></dt>
|
|
<dd>The system determines the best value to use. A value of *CALC must be specified for those devices not attached to an X.25 network. *CALC may be specified for devices attached to an X.25 network. In all instances, *CALC is the recommended value.
|
|
</dd>
|
|
<dt><b><i>maximum-length-request-unit</i></b></dt>
|
|
<dd>Specify 241 or 247. These values are valid only for devices attached to X.25 networks. If the recommended value of *CALC is not specified, it is recommended that 241 be used for ELLC and 247 be used for QLLC. The values 245 and 256 can be specified, but the result is the same as specifying *CALC.
|
|
</dd>
|
|
</dl>
|
|
</div>
|
|
<table width="100%">
|
|
<tr><td align="right"><a href="#CRTDEVDSP.Top_Of_Page">Top</a></td></tr>
|
|
</table>
|
|
<div> <a name="CRTDEVDSP.APPTYPE"></a>
|
|
<h3>Application type (APPTYPE)</h3>
|
|
<p>Specifies the application type used by this device.
|
|
</p>
|
|
<dl>
|
|
<dt><b><u>*NONE</u></b></dt>
|
|
<dd>The device is not used for any application.
|
|
</dd>
|
|
<dt><b>*NRF</b></dt>
|
|
<dd>The device is used for the Network Routing Facility application.
|
|
</dd>
|
|
<dt><b>*CTLSSN</b></dt>
|
|
<dd>The device controls the sessions with *DEVINIT devices.
|
|
</dd>
|
|
<dt><b>*DEVINIT</b></dt>
|
|
<dd>The device starts (initiates) the session.
|
|
</dd>
|
|
<dt><b>*APPINIT</b></dt>
|
|
<dd>The application program starts (initiates) the session.
|
|
</dd>
|
|
</dl>
|
|
</div>
|
|
<table width="100%">
|
|
<tr><td align="right"><a href="#CRTDEVDSP.Top_Of_Page">Top</a></td></tr>
|
|
</table>
|
|
<div> <a name="CRTDEVDSP.ACTTMR"></a>
|
|
<h3>Activation timer (ACTTMR)</h3>
|
|
<p>Specifies, for switched connections, the amount of time (in seconds) that the SNA pass-through support waits for the device to respond to the activation request from the host iSeries system. If the device does not respond within this time, it is considered not available.
|
|
</p>
|
|
<p>This parameter is valid only when *SNPT is specified for the DEVCLS parameter.
|
|
</p>
|
|
<dl>
|
|
<dt><b><u>170</u></b></dt>
|
|
<dd>Specifies the activate time of 170 seconds.
|
|
</dd>
|
|
<dt><b><i>activate-time</i></b></dt>
|
|
<dd>Specify a number ranging from 1 through 2550 indicating the number of seconds before the device is considered not available.
|
|
</dd>
|
|
</dl>
|
|
</div>
|
|
<table width="100%">
|
|
<tr><td align="right"><a href="#CRTDEVDSP.Top_Of_Page">Top</a></td></tr>
|
|
</table>
|
|
<div> <a name="CRTDEVDSP.INACTTMR"></a>
|
|
<h3>Inactivity timer (INACTTMR)</h3>
|
|
<p>Specifies an inactivity timer (time-out) value for display devices. This parameter also specifies what happens when the time-out value is exceeded, dependent on other attributes of the device:
|
|
</p>
|
|
<ul>
|
|
<li>For display stations attached to an ASCII work station controller, the user's job is canceled when the display station is inactive (no data is sent or received) for a period of time that exceeds the time-out value. The display station is automatically varied off and on again, resulting in a new sign-on display.
|
|
</li>
|
|
<li>For display devices connected using SNA pass-through (SNPT) support, the user is informed by a message to QSYSOPR and the session is ended when the amount of time that the device is not bound to a host application exceeds the time-out value. The user must reestablish the connection and session.
|
|
</li>
|
|
<li>For display devices with an application type value of *APPINIT, *DEVINIT, or *NRF, the session is ended when the device is inactive (the file opened against the device is closed and no additional requests to open files are received for the device) for a period of time that exceeds the time-out value.
|
|
</li>
|
|
</ul>
|
|
<p>
|
|
<b>Note: </b>This timer is not used by devices allocated to a subsystem (normal interactive use) because the subsystem always has a file open for the device. The timer is used by batch jobs that open and close files for the device.
|
|
</p>
|
|
<p>For a connection using SNA pass-through (*SNPT) device class support, the default of *ATTACH maps to *NOMAX.
|
|
</p>
|
|
<p>For a device with an application type value of *APPINIT, *CLTSSN, *DEVINIT, or *NRF, the default of *ATTACH maps to 1 minute.
|
|
</p>
|
|
<p>For Post Telephone and Telegraph (*PTT) attachment, valid inactivity timer values are *SEC15 (15 seconds), *SEC30 (30 seconds), and 1 to 10 minutes. The default of *ATTACH maps to *SEC30 (30 seconds).
|
|
</p>
|
|
<p>For all other attachments, valid inactivity timer values are 1 to 30 minutes and *NOMAX. The default of *ATTACH maps to *NOMAX for these attachments.
|
|
</p>
|
|
<dl>
|
|
<dt><b><u>*ATTACH</u></b></dt>
|
|
<dd>This value varies by the value specified on the <b>Physical attachment (ATTACH)</b> parameter and certain values on the <b>Application type (APPTYPE)</b> parameter and <b>Device class (DEVCLS)</b> parameter.
|
|
</dd>
|
|
<dt><b>*NOMAX</b></dt>
|
|
<dd>No maximum inactivity time is tracked (no inactivity timer is to be enforced).
|
|
</dd>
|
|
<dt><b>*SEC15</b></dt>
|
|
<dd>A 15-second time-out period is used.
|
|
</dd>
|
|
<dt><b>*SEC30</b></dt>
|
|
<dd>A 30-second time-out period is used.
|
|
</dd>
|
|
<dt><b><i>inactivity-timer</i></b></dt>
|
|
<dd>Specifies a time-out value in minutes.
|
|
</dd>
|
|
</dl>
|
|
</div>
|
|
<table width="100%">
|
|
<tr><td align="right"><a href="#CRTDEVDSP.Top_Of_Page">Top</a></td></tr>
|
|
</table>
|
|
<div> <a name="CRTDEVDSP.SNPTDEV"></a>
|
|
<h3>SNA pass-through device desc (SNPTDEV)</h3>
|
|
<p>Specifies the name of the associated SNA pass-through device that is attached to a host or advanced program-to-program communications (APPC) controller.
|
|
</p>
|
|
<dl>
|
|
<dt><b><u>*NONE</u></b></dt>
|
|
<dd>No name is specified.
|
|
</dd>
|
|
<dt><b><i>associated-device-name</i></b></dt>
|
|
<dd>Specify the name of a device that is attached to a host or an APPC controller that is associated with this device.
|
|
</dd>
|
|
</dl>
|
|
</div>
|
|
<table width="100%">
|
|
<tr><td align="right"><a href="#CRTDEVDSP.Top_Of_Page">Top</a></td></tr>
|
|
</table>
|
|
<div> <a name="CRTDEVDSP.SNPTGRP"></a>
|
|
<h3>SNA pass-through group name (SNPTGRP)</h3>
|
|
<p>Specifies the name configured for a group of host devices in a configuration list. This indicates that this device is associated with any one of the devices in that group which is available.
|
|
</p>
|
|
<dl>
|
|
<dt><b><u>*NONE</u></b></dt>
|
|
<dd>No name is specified.
|
|
</dd>
|
|
<dt><b><i>group-name</i></b></dt>
|
|
<dd>Specify the name configured for a group of host devices that must be associated with this device.
|
|
</dd>
|
|
</dl>
|
|
</div>
|
|
<table width="100%">
|
|
<tr><td align="right"><a href="#CRTDEVDSP.Top_Of_Page">Top</a></td></tr>
|
|
</table>
|
|
<div> <a name="CRTDEVDSP.LOGON"></a>
|
|
<h3>Host signon/logon command (LOGON)</h3>
|
|
<p>Specifies the sign-on (logon) text. This parameter is allowed when DEVCLS(*SNPT) or APPTYPE(*NRF) is specified. APPTYPE(*NRF) specifies the logon string that is sent to the host system when a request is made to establish a session. DEVCLS(*SNPT) specifies the sign-on (logon) text that is sent to the host system after starting SNA pass-through support.
|
|
</p>
|
|
<p>This parameter also specifies the logon string that is sent to the system services control point (SSCP) on the host network when the file is opened for *NRF.
|
|
</p>
|
|
<dl>
|
|
<dt><b><u>*NONE</u></b></dt>
|
|
<dd>No text is sent to the host system.
|
|
</dd>
|
|
<dt><b><i>host-logon-command</i></b></dt>
|
|
<dd>Specify text that is sent to the host system. The text must be enclosed in apostrophes if it contains blanks or other special characters. All apostrophes within the text must be represented by two apostrophes. A maximum of 256 characters can be specified.
|
|
</dd>
|
|
</dl>
|
|
</div>
|
|
<table width="100%">
|
|
<tr><td align="right"><a href="#CRTDEVDSP.Top_Of_Page">Top</a></td></tr>
|
|
</table>
|
|
<div> <a name="CRTDEVDSP.LINESPEED"></a>
|
|
<h3>Line speed (LINESPEED)</h3>
|
|
<p>Specifies the line speed in bits per second (bps).
|
|
</p>
|
|
<dl>
|
|
<dt><b><u>*TYPE</u></b></dt>
|
|
<dd>The system uses the suggested setting for this device type. *TYPE selects 19200 bits per second for all display stations except the 3101 display station for which 9600 bits per second is selected. For a 5150 A1 device or a device type of *CALC, *TYPE selects 1200 bits per second.
|
|
</dd>
|
|
<dt><b>*CALC</b></dt>
|
|
<dd>The system automatically calculates the line speed for displays attached to this port. If *CALC is specified, it must also be specified on the <b>Type of parity (PARITY)</b> parameter and the <b>Word length (WORDLEN)</b> parameter.
|
|
<p>
|
|
<b>Note: </b>Specifying *CALC allows port sharing for ASCII devices. ASCII port sharing allows different device types, using different physical parameters, to use the same port (at different times) without needing to manually reconfigure the port.
|
|
</p>
|
|
<p>More information on ASCII port sharing is in the Local Device Configuration book, SC41-5121 book or the ASCII Work Station Reference, SA41-3130.
|
|
</p>
|
|
</dd>
|
|
<dt><b><i>line-speed</i></b></dt>
|
|
<dd>Specify the line speed. Valid values are: 150, 300, 600, 1200, 1800, 2400, 3600, 4800, 7200, 9600, 19200, or 38400.
|
|
</dd>
|
|
</dl>
|
|
</div>
|
|
<table width="100%">
|
|
<tr><td align="right"><a href="#CRTDEVDSP.Top_Of_Page">Top</a></td></tr>
|
|
</table>
|
|
<div> <a name="CRTDEVDSP.WORDLEN"></a>
|
|
<h3>Word length (WORDLEN)</h3>
|
|
<p>Specifies, for ASCII devices, the word length (bits per character) used to communicate over the attachment between the ASCII work station controller and the device. For modem and Post Telephone and Telegraph (PTT) attachments, the word length must be the same as the word length selected for the modem. For auxiliary printers connected to the auxiliary port of a display station, the word length must be the same as the word length specified for the display's device description.
|
|
</p>
|
|
<p>Some devices do not support all word lengths; verify that your device supports the word length you intend to use.
|
|
</p>
|
|
<dl>
|
|
</dl>
|
|
<dl>
|
|
<dt><b><u>*TYPE</u></b></dt>
|
|
<dd>The system uses the suggested setting for this device type. *TYPE selects 8 bit word lengths for all display stations except the 3101 and D220 display stations which select 7 bit word lengths.
|
|
</dd>
|
|
</dl>
|
|
<dl>
|
|
<dt><b>7</b></dt>
|
|
<dd>Specifies 7 bit word lengths.
|
|
</dd>
|
|
<dt><b>8</b></dt>
|
|
<dd>Specifies 8 bit word lengths.
|
|
</dd>
|
|
<dt><b>*CALC</b></dt>
|
|
<dd>Specifies port sharing. If *CALC is specified, the system automatically calculates the word lengths for displays attached to this port.
|
|
<p>More information on ASCII port sharing is in the Local Device Configuration book, SC41-5121 book or the ASCII Work Station Reference, SA41-3130.
|
|
</p>
|
|
</dd>
|
|
</dl>
|
|
</div>
|
|
<table width="100%">
|
|
<tr><td align="right"><a href="#CRTDEVDSP.Top_Of_Page">Top</a></td></tr>
|
|
</table>
|
|
<div> <a name="CRTDEVDSP.PARITY"></a>
|
|
<h3>Type of parity (PARITY)</h3>
|
|
<p>Specifies, for ASCII devices, the type of parity used to communicate over the attachment between the ASCII work station controller and the device. For modem and Post Telephone and Telegraph (PTT) attachments, the type of parity must be the same as the type of parity selected for the modem. For auxiliary printers connected to the auxiliary port of a display station, the type of parity must be the same as the type of parity specified for the display's device description.
|
|
</p>
|
|
<p>Some devices do not support all types of parity; verify that your device supports the type of parity you intend to use.
|
|
</p>
|
|
<dl>
|
|
<dt><b><u>*TYPE</u></b></dt>
|
|
<dd>The system uses the suggested setting for this device type. *TYPE selects *EVEN (Even parity) for all display stations except for the D220 which selects *MARK. For a 5150 A1 device, *TYPE selects *NONE for an 8 bit word length and *EVEN for a 7 bit word length. If *CALC is specified for the <b>Device type (TYPE)</b> parameter, *TYPE selects *NONE.
|
|
</dd>
|
|
<dt><b>*CALC</b></dt>
|
|
<dd>Specifies port sharing. If *CALC is specified, the system automatically calculates the parity for displays attached to this port.
|
|
</dd>
|
|
<dt><b>*EVEN</b></dt>
|
|
<dd>Even parity is used.
|
|
</dd>
|
|
<dt><b>*ODD</b></dt>
|
|
<dd>Odd parity is used.
|
|
</dd>
|
|
<dt><b>*NONE</b></dt>
|
|
<dd>Specifies that no parity bit is used.
|
|
</dd>
|
|
<dt><b>*MARK</b></dt>
|
|
<dd>Mark parity (1 is used for the parity) is used.
|
|
</dd>
|
|
<dt><b>*SPACE</b></dt>
|
|
<dd>Space parity (0 is used for the parity) is used.
|
|
<p>More information on ASCII port sharing is in the Local Device Configuration book, SC41-5121 book and the ASCII Work Station Reference, SA41-3130.
|
|
</p>
|
|
</dd>
|
|
</dl>
|
|
</div>
|
|
<table width="100%">
|
|
<tr><td align="right"><a href="#CRTDEVDSP.Top_Of_Page">Top</a></td></tr>
|
|
</table>
|
|
<div> <a name="CRTDEVDSP.STOPBITS"></a>
|
|
<h3>Stop bits (STOPBITS)</h3>
|
|
<p>Specifies, for ASCII devices, the number of stop bits used to communicate over the attachment between the ASCII work station controller and the device. For modem and Post Telephone and Telegraph (PTT) attachments, the number of stop bits must be the same as the number of stop bits selected for the modem. For auxiliary printers connected to the auxiliary port of a display station, the number of stop bits must be the same as the number of stop bits specified for the display's device description.
|
|
</p>
|
|
<p>Some devices do not support all numbers of stop bits; verify that your device supports the number of stop bits you intend to use.
|
|
</p>
|
|
<dl>
|
|
<dt><b><u>*TYPE</u></b></dt>
|
|
<dd>The system uses the suggested setting for this device type. *TYPE selects 1 stop bit for all displays except the DEC VT-100 display station, for which a setting of 2 stop bits is selected.
|
|
</dd>
|
|
<dt><b>1</b></dt>
|
|
<dd>Specifies 1 stop bit.
|
|
</dd>
|
|
<dt><b>2</b></dt>
|
|
<dd>Specifies 2 stop bits.
|
|
</dd>
|
|
</dl>
|
|
</div>
|
|
<table width="100%">
|
|
<tr><td align="right"><a href="#CRTDEVDSP.Top_Of_Page">Top</a></td></tr>
|
|
</table>
|
|
<div> <a name="CRTDEVDSP.MAXOUT"></a>
|
|
<h3>Maximum outstanding frames (MAXOUT)</h3>
|
|
<p>Specifies the maximum number of frames that are sent sequentially to a remote system before the remote system (the 5150 work station) must respond. The maximum number of frames must be between 1 and 7. This parameter is valid only if 5150 is specified for the <b>Device type (TYPE)</b> parameter and A1 is specified for the <b>Device model (MODEL)</b> parameter or if ASCII port sharing is being used.
|
|
</p>
|
|
<dl>
|
|
<dt><b><u>7</u></b></dt>
|
|
<dd>The default number of frames sent is 7.
|
|
</dd>
|
|
<dt><b><i>maximum-outstanding-frames</i></b></dt>
|
|
<dd>Specify a value from 1 to 7 for the number of frames.
|
|
</dd>
|
|
</dl>
|
|
</div>
|
|
<table width="100%">
|
|
<tr><td align="right"><a href="#CRTDEVDSP.Top_Of_Page">Top</a></td></tr>
|
|
</table>
|
|
<div> <a name="CRTDEVDSP.IDLTMR"></a>
|
|
<h3>Idle timer (IDLTMR)</h3>
|
|
<p>Specifies the time (in 0.1 second intervals) that the system waits for a response. If no response is received in the specified amount of time, then error recovery procedures are started. This parameter is valid only if the number is between 10 and 250, and if 5150 is specified for the <b>Device type (TYPE)</b> parameter and A1 is specified for the <b>Device model (MODEL)</b> parameter, or if ASCII port sharing is being used.
|
|
</p>
|
|
<dl>
|
|
<dt><b><u>40</u></b></dt>
|
|
<dd>The default is 4.0 seconds.
|
|
</dd>
|
|
<dt><b><i>idle-timer</i></b></dt>
|
|
<dd>Specify a value from 10 to 250 in 0.1 second intervals.
|
|
</dd>
|
|
</dl>
|
|
</div>
|
|
<table width="100%">
|
|
<tr><td align="right"><a href="#CRTDEVDSP.Top_Of_Page">Top</a></td></tr>
|
|
</table>
|
|
<div> <a name="CRTDEVDSP.NRMPOLLTMR"></a>
|
|
<h3>NRM poll timer (NRMPOLLTMR)</h3>
|
|
<p>Specifies the interval (in 0.1 second intervals) for polling this device when it is in normal response mode (NRM). This parameter is valid only if 5150 is specified for the <b>Device type (TYPE)</b> parameter and A1 is specified for the <b>Device model (MODEL)</b> parameter or if ASCII port sharing is being used.
|
|
</p>
|
|
<dl>
|
|
<dt><b><u>3</u></b></dt>
|
|
<dd>The default is 0.3 seconds.
|
|
</dd>
|
|
<dt><b><i>NRM-poll-timer</i></b></dt>
|
|
<dd>Specify a value from 2 to 100 in 0.1 second intervals.
|
|
</dd>
|
|
</dl>
|
|
</div>
|
|
<table width="100%">
|
|
<tr><td align="right"><a href="#CRTDEVDSP.Top_Of_Page">Top</a></td></tr>
|
|
</table>
|
|
<div> <a name="CRTDEVDSP.FRAMERTY"></a>
|
|
<h3>Frame retry (FRAMERTY)</h3>
|
|
<p>Specifies the number of retries for an unanswered command frame or unacknowledged information frame. This parameter is valid only if 5150 is specified for the <b>Device type (TYPE)</b> parameter and A1 is specified for the <b>Device model (MODEL)</b> parameter or if ASCII port sharing is being used.
|
|
</p>
|
|
<dl>
|
|
<dt><b><u>15</u></b></dt>
|
|
<dd>The default value is 15 retries.
|
|
</dd>
|
|
<dt><b><i>frame-retry</i></b></dt>
|
|
<dd>Specify a value from 5 to 64 for the number of retries.
|
|
</dd>
|
|
</dl>
|
|
</div>
|
|
<table width="100%">
|
|
<tr><td align="right"><a href="#CRTDEVDSP.Top_Of_Page">Top</a></td></tr>
|
|
</table>
|
|
<div> <a name="CRTDEVDSP.RMTLOCNAME"></a>
|
|
<h3>Remote location (RMTLOCNAME)</h3>
|
|
<p>Specifies the remote location name of the system with which this object communicates.
|
|
</p>
|
|
<p>
|
|
<b>Note: </b>This parameter is required for APPTYPE(*APPINIT) devices. The remote location name for APPTYPE(*APPINIT) devices is the VTAM/NCP (Virtual Telecommunications Access Method/Network Control Program) name of the physical device.
|
|
</p>
|
|
</div>
|
|
<table width="100%">
|
|
<tr><td align="right"><a href="#CRTDEVDSP.Top_Of_Page">Top</a></td></tr>
|
|
</table>
|
|
<div> <a name="CRTDEVDSP.LCLLOCNAME"></a>
|
|
<h3>Local location (LCLLOCNAME)</h3>
|
|
<p>Specifies the local location name. When this parameter is specified with APPTYPE(*CTLSSN) or APPTYPE(*APPINIT), the remote location name is the name of the independent logical unit (LU) in the network control program (NCP).
|
|
</p>
|
|
<dl>
|
|
<dt><b><u>*NETATR</u></b></dt>
|
|
<dd>The LCLLOCNAME value specified in the system network attributes is used.
|
|
</dd>
|
|
<dt><b><i>local-location-name</i></b></dt>
|
|
<dd>Specify the local location name.
|
|
</dd>
|
|
</dl>
|
|
</div>
|
|
<table width="100%">
|
|
<tr><td align="right"><a href="#CRTDEVDSP.Top_Of_Page">Top</a></td></tr>
|
|
</table>
|
|
<div> <a name="CRTDEVDSP.RMTNETID"></a>
|
|
<h3>Remote network identifier (RMTNETID)</h3>
|
|
<p>Specifies the name of the remote network identifier (ID). This parameter can be specified for APPTYPE(*APPINIT) devices.
|
|
</p>
|
|
<dl>
|
|
<dt><b><u>*NETATR</u></b></dt>
|
|
<dd>The RMTNETID value specified in the system network attributes is used.
|
|
</dd>
|
|
<dt><b>*NONE</b></dt>
|
|
<dd>No remote network identifier (ID) is used.
|
|
</dd>
|
|
<dt><b><i>remote-network-ID</i></b></dt>
|
|
<dd>Specify the name of the remote network identifier.
|
|
</dd>
|
|
</dl>
|
|
</div>
|
|
<table width="100%">
|
|
<tr><td align="right"><a href="#CRTDEVDSP.Top_Of_Page">Top</a></td></tr>
|
|
</table>
|
|
<div> <a name="CRTDEVDSP.IGCFEAT"></a>
|
|
<h3>DBCS feature (IGCFEAT)</h3>
|
|
<p>Specifies which double-byte character set (DBCS) table is used in DBCS feature code format expressing device features and the last code point value. The table at the end of this parameter description shows valid device features and last code point values for DBCS-capable devices.
|
|
</p>
|
|
<p>
|
|
<b>Note: </b>This parameter is valid for DBCS-capable devices only.
|
|
</p>
|
|
<p><b>Element 1: Features of the DBCS-Capable Devices</b>
|
|
</p>
|
|
<dl>
|
|
<dt><b><i>device-features</i></b></dt>
|
|
<dd>Specify the device character resolution, language, and relative buffer size device features using the format SSSSLR, where:
|
|
<dl>
|
|
<dt><b>SSSS =</b></dt>
|
|
<dd>The resolution (number of matrix points used to create) of the character. For example, 2424 would be 24 matrix points of height and 24 matrix points of width available to formulate the character.
|
|
</dd>
|
|
<dt><b>L =</b></dt>
|
|
<dd>The language code. The 4 language codes currently supported are:
|
|
<ul>
|
|
<li>J = Japanese
|
|
</li>
|
|
<li>K = Korean
|
|
</li>
|
|
<li>C = Traditional Chinese
|
|
</li>
|
|
<li>S = Simplified Chinese
|
|
</li>
|
|
</ul>
|
|
</dd>
|
|
<dt><b>R =</b></dt>
|
|
<dd>The relative buffer size. The valid values are: 0, 1, 2, and 4.
|
|
</dd>
|
|
</dl>
|
|
</dd>
|
|
</dl>
|
|
<p><b>Element 2: Last Code Point</b>
|
|
</p>
|
|
<dl>
|
|
<dt><b><i>last-code-point</i></b></dt>
|
|
<dd>Specify the 4-digit code point of the last double-byte character. This value can be blank.
|
|
</dd>
|
|
</dl>
|
|
</div>
|
|
<table width="100%">
|
|
<tr><td align="right"><a href="#CRTDEVDSP.Top_Of_Page">Top</a></td></tr>
|
|
</table>
|
|
<div> <a name="CRTDEVDSP.TEXT"></a>
|
|
<h3>Text 'description' (TEXT)</h3>
|
|
<p>Specifies the text that briefly describes the object.
|
|
</p>
|
|
<dl>
|
|
<dt><b>*BLANK</b></dt>
|
|
<dd>No text is specified.
|
|
</dd>
|
|
<dt><b><i>character-value</i></b></dt>
|
|
<dd>Specify no more than 50 characters of text, enclosed in apostrophes.
|
|
</dd>
|
|
</dl>
|
|
</div>
|
|
<table width="100%">
|
|
<tr><td align="right"><a href="#CRTDEVDSP.Top_Of_Page">Top</a></td></tr>
|
|
</table>
|
|
<div> <a name="CRTDEVDSP.DEPLOCNAME"></a>
|
|
<h3>Dependent location name (DEPLOCNAME)</h3>
|
|
<p>Specifies the dependent local location name used for Dependent LU Requester (DLUR), providing additional security for the connection. If this name is filled in, an activation request (SNA ACTLU) from a Dependent LU Server (DLUS) node must reference this name or it is rejected.
|
|
</p>
|
|
<p>Remote DLUS nodes may optionally accept unsolicited reply PSIDs (Product Set IDs) from the iSeries for auto-definition of LUs at the DLUS node. If so, then this name will be sent to the DLUS node in the reply PSID and it will be returned on the ACTLU request.
|
|
</p>
|
|
<p>If unsolicited reply PSIDs are not supported by the DLUS node, then there will have to be close coordination of the PU name definitions on both systems.
|
|
</p>
|
|
<dl>
|
|
<dt><b>*NONE</b></dt>
|
|
<dd>No location name is defined.
|
|
</dd>
|
|
<dt><b><i>dependent-location-name</i></b></dt>
|
|
<dd>Specify the dependent location name used for DLUR applications.
|
|
</dd>
|
|
</dl>
|
|
</div>
|
|
<table width="100%">
|
|
<tr><td align="right"><a href="#CRTDEVDSP.Top_Of_Page">Top</a></td></tr>
|
|
</table>
|
|
<div> <a name="CRTDEVDSP.CHRID"></a>
|
|
<h3>Character identifier (CHRID)</h3>
|
|
<p>Specifies the character identifier (graphic character set and code page) that a work station display device supports.
|
|
</p>
|
|
<dl>
|
|
<dt><b><u>*KBDTYPE</u></b></dt>
|
|
<dd>The system determines the graphic character set and code page value that corresponds to the country keyboard language identifier value specified for the <b>Keyboard language type (KBDTYPE)</b> parameter.
|
|
</dd>
|
|
</dl>
|
|
<dl>
|
|
<dt><b><u>*SYSVAL</u></b></dt>
|
|
<dd>The system determines the graphic character set and code page values for the command parameters from the QCHRID system value.
|
|
</dd>
|
|
</dl>
|
|
<dl>
|
|
<dt><b><i>graphic-character-set code-page</i></b></dt>
|
|
<dd>Specify the graphic character set and code page values that match the attributes of this display device. The graphic character set and code page values must be numbers in the range of 1 through 32767.
|
|
</dd>
|
|
</dl>
|
|
</div>
|
|
<table width="100%">
|
|
<tr><td align="right"><a href="#CRTDEVDSP.Top_Of_Page">Top</a></td></tr>
|
|
</table>
|
|
<div> <a name="CRTDEVDSP.PRTDEV"></a>
|
|
<h3>Print device (PRTDEV)</h3>
|
|
<p>Specifies the qualified name of the default printer device for this workstation. If the printer file being used to create the output specifies to spool the file, the spooled file is placed on the device's output queue, which is named the same as the device.
|
|
</p>
|
|
<p>
|
|
<b>Note: </b>This assumes the defaults are specified on the OUTQ parameter for the printer file, job description, user profile and workstation.
|
|
</p>
|
|
<dl>
|
|
<dt><b><u>*SYSVAL</u></b></dt>
|
|
<dd>The default system printer specified in the system value QPRTDEV is used.
|
|
</dd>
|
|
<dt><b><i>printer-device-name</i></b></dt>
|
|
<dd>Specify the name of a printer that is used to print the output.
|
|
</dd>
|
|
</dl>
|
|
</div>
|
|
<table width="100%">
|
|
<tr><td align="right"><a href="#CRTDEVDSP.Top_Of_Page">Top</a></td></tr>
|
|
</table>
|
|
<div> <a name="CRTDEVDSP.OUTQ"></a>
|
|
<h3>Output queue (OUTQ)</h3>
|
|
<p>Specifies the output queue (*OUTQ) object.
|
|
</p>
|
|
<p>The possible <b>output queue name</b> values are:
|
|
</p>
|
|
<dl>
|
|
<dt><b><u>*DEV</u></b></dt>
|
|
<dd>The output queue associated with the printer specified on the DEV parameter of the printer file is used. The output queue has the same name as the printer. (The printer file DEV parameter is determined by the CRTPRTF, CHGPRTF, or the OVRPRTF command).
|
|
<p>
|
|
<b>Note: </b>This assumes the defaults were specified on the OUTQ parameter for the printer file, job description, user profile, and workstation.
|
|
</p>
|
|
</dd>
|
|
<dt><b><i>output-queue-name</i></b></dt>
|
|
<dd>Specify the name of the output queue.
|
|
</dd>
|
|
</dl>
|
|
<p>The possible library values are:
|
|
</p>
|
|
<dl>
|
|
<dt><b><u>*LIBL</u></b></dt>
|
|
<dd>All libraries in the library list for the current thread are searched until the first match is found.
|
|
</dd>
|
|
</dl>
|
|
<dl>
|
|
<dt><b>*CURLIB</b></dt>
|
|
<dd>The current library is used to locate the output queue. If no current library entry exists in the library list, QGPL is used.
|
|
</dd>
|
|
<dt><b><i>library-name</i></b></dt>
|
|
<dd>Specify the name of the library where the output queue is located.
|
|
</dd>
|
|
</dl>
|
|
</div>
|
|
<table width="100%">
|
|
<tr><td align="right"><a href="#CRTDEVDSP.Top_Of_Page">Top</a></td></tr>
|
|
</table>
|
|
<div> <a name="CRTDEVDSP.PRTFILE"></a>
|
|
<h3>Printer file (PRTFILE)</h3>
|
|
<p>Specifies an alternative printer device file to be used for processing the Print key on this display station.
|
|
</p>
|
|
<p>The printer file is specified by its qualified name (library-name/print-file-name).
|
|
</p>
|
|
<p>The possible library values are:
|
|
</p>
|
|
<dl>
|
|
<dt><b><u>*LIBL</u></b></dt>
|
|
<dd>All libraries in the library list for the current thread are searched until the first match is found.
|
|
</dd>
|
|
</dl>
|
|
<dl>
|
|
<dt><b>*CURLIB</b></dt>
|
|
<dd>The current library for the thread is searched. If no library is specified as the current library for the thread, the QGPL library is searched.
|
|
</dd>
|
|
</dl>
|
|
<dl>
|
|
<dt><b><i>library-name</i></b></dt>
|
|
<dd>Specify the library where the object is located.
|
|
</dd>
|
|
</dl>
|
|
</div>
|
|
<table width="100%">
|
|
<tr><td align="right"><a href="#CRTDEVDSP.Top_Of_Page">Top</a></td></tr>
|
|
</table>
|
|
<div> <a name="CRTDEVDSP.WSCST"></a>
|
|
<h3>Workstation customizing object (WSCST)</h3>
|
|
<p>Specifies the qualified name of a work station customizing object to be created.
|
|
</p>
|
|
<dl>
|
|
<dt><b><u>*NONE</u></b></dt>
|
|
<dd>No work station customizing object is specified.
|
|
</dd>
|
|
<dt><b><i>work-station-customizing-object</i></b></dt>
|
|
<dd>Specify the work station customizing object.
|
|
<p>
|
|
<b>Note: </b>If a work station customizing object is specified for the WSCST parameter, all country keyboard identifiers are valid for ASCII devices except for the following: FQB, FQI, INB, INI, JEB, JEI, JKB, JUB, KAB, KOB, RCB, and TAB.
|
|
</p>
|
|
</dd>
|
|
</dl>
|
|
<p>The possible library values are:
|
|
</p>
|
|
<dl>
|
|
<dt><b><u>*LIBL</u></b></dt>
|
|
<dd>All libraries in the library list for the current thread are searched until the first match is found.
|
|
</dd>
|
|
</dl>
|
|
<dl>
|
|
<dt><b>*CURLIB</b></dt>
|
|
<dd>The current library for the thread is searched. If no library is specified as the current library for the thread, the QGPL library is searched.
|
|
</dd>
|
|
</dl>
|
|
<dl>
|
|
<dt><b><i>library-name</i></b></dt>
|
|
<dd>Specify the library where the object is located.
|
|
</dd>
|
|
</dl>
|
|
</div>
|
|
<table width="100%">
|
|
<tr><td align="right"><a href="#CRTDEVDSP.Top_Of_Page">Top</a></td></tr>
|
|
</table>
|
|
<div> <a name="CRTDEVDSP.AUT"></a>
|
|
<h3>Authority (AUT)</h3>
|
|
<p>Specifies the authority you are giving to users who do not have specific authority for the object, who are not on an authorization list, and whose group profile or supplemental group profiles do not have specific authority for the object.
|
|
</p>
|
|
<dl>
|
|
<dt><b><u>*CHANGE</u></b></dt>
|
|
<dd>The user can perform all operations on the object except those limited to the owner or controlled by object existence (*OBJEXIST) and object management (*OBJMGT) authorities. The user can change and perform basic functions on the object. *CHANGE authority provides object operational (*OBJOPR) authority and all data authority. If the object is an authorization list, the user cannot add, change, or remove users.
|
|
</dd>
|
|
</dl>
|
|
<dl>
|
|
<dt><b>*ALL</b></dt>
|
|
<dd>The user can perform all operations except those limited to the owner or controlled by authorization list management (*AUTLMGT) authority. The user can control the object's existence, specify the security for the object, change the object, and perform basic functions on the object. The user also can change ownership of the object.
|
|
</dd>
|
|
</dl>
|
|
<dl>
|
|
<dt><b>*USE</b></dt>
|
|
<dd>The user can perform basic operations on the object, such as running a program or reading a file. The user cannot change the object. Use (*USE) authority provides object operational (*OBJOPR), read (*READ), and execute (*EXECUTE) authorities.
|
|
</dd>
|
|
</dl>
|
|
<dl>
|
|
<dt><b>*EXCLUDE</b></dt>
|
|
<dd>The user cannot access the object.
|
|
</dd>
|
|
</dl>
|
|
<dl>
|
|
<dt><b>*LIBCRTAUT</b></dt>
|
|
<dd>The system determines the authority for the object by using the value specified for the <b>Create authority (CRTAUT)</b> parameter on the Create Library (CRTLIB) command for the library containing the object to be created. If the value specified for the CRTAUT parameter is changed, the new value will not affect any existing objects.
|
|
</dd>
|
|
</dl>
|
|
<dl>
|
|
<dt><b><i>name</i></b></dt>
|
|
<dd>Specify the name of an authorization list to be used for authority to the object. Users included in the authorization list are granted authority to the object as specified in the list. The authorization list must exist when the object is created.
|
|
</dd>
|
|
</dl>
|
|
</div>
|
|
<table width="100%">
|
|
<tr><td align="right"><a href="#CRTDEVDSP.Top_Of_Page">Top</a></td></tr>
|
|
</table>
|
|
<hr size="2" width="100%">
|
|
<div><h3><a name="CRTDEVDSP.COMMAND.EXAMPLES">Examples</a> </h3>
|
|
<p>
|
|
<pre>
|
|
CRTDEVDSP DEVD(DSP4) TYPE(3180) MODEL(2)
|
|
DEVCLS(*LCL) PORT(0)
|
|
SWTSET(4) CTL(CTL01) KBDTYPE(USB)
|
|
</pre>
|
|
</p>
|
|
<p>This command creates a 3180 Model 2 local device description called DSP4. The display station is located on port 0 of the local work station controller CTL01. The device has an address of 4, with a United States/Canadian keyboard.
|
|
</p>
|
|
</div>
|
|
<table width="100%">
|
|
<tr><td align="right"><a href="#CRTDEVDSP.Top_Of_Page">Top</a></td></tr>
|
|
</table>
|
|
<hr size="2" width="100%">
|
|
<div><h3><a name="CRTDEVDSP.ERROR.MESSAGES">Error messages</a> </h3>
|
|
<p><b><u>*ESCAPE Messages</u></b>
|
|
</p>
|
|
<dl>
|
|
<dt><b>CPF261A</b></dt>
|
|
<dd>Device description &1 not created due to errors.
|
|
</dd>
|
|
<dt><b>CPF2631</b></dt>
|
|
<dd>Device type &2 not valid.
|
|
</dd>
|
|
</dl>
|
|