ibm-information-center/dist/eclipse/plugins/i5OS.ic.apis_5.4.0.1/qzdmostr.htm

227 lines
6.8 KiB
HTML

<!DOCTYPE html PUBLIC "-//W3C//DTD HTML 4.01 Transitional//EN">
<html>
<head>
<meta http-equiv="Content-Type" content="text/html; charset=utf-8">
<meta name="Copyright" content="Copyright (c) 2006 by IBM Corporation">
<title>Open Stream (QzdmOpenStream) API</title>
<!-- Begin Header Records ========================================== -->
<!-- All rights reserved. Licensed Materials Property of IBM -->
<!-- US Government Users Restricted Rights -->
<!-- Use, duplication or disclosure restricted by -->
<!-- GSA ADP Schedule Contract with IBM Corp. -->
<!-- COMM4 SCRIPT A converted by B2H R4.1 (346) (CMS) by V2DCIJB at -->
<!-- RCHVMW2 on 1 Jun 1999 at 17:32:50 -->
<!-- Change History: -->
<!-- YYMMDD USERID Change description -->
<!--File Edited December, 2001 =========================================== -->
<!--End Header Records ============================================== -->
<link rel="stylesheet" type="text/css" href="../rzahg/ic.css">
</head>
<body>
<a name="Top_Of_Page"></a>
<!-- Java sync-link ================================================= -->
<script type="text/javascript" language="Javascript" src="../rzahg/synch.js">
</script>
<h2>Open Stream (QzdmOpenStream) API</h2>
<div class="box" style="width: 60%;">
&nbsp;&nbsp;Required Parameter Group:<br>
<!-- iddvc RMBR -->
<br>
<table width="100%">
<tr>
<td align="center" valign="top" width="10%">1</td>
<td align="left" valign="top" width="50%">Receiver variable</td>
<td align="left" valign="top" width="20%">Output</td>
<td align="left" valign="top" width="20%">Char(*)</td>
</tr>
<tr>
<td align="center" valign="top">2</td>
<td align="left" valign="top">Length of receiver variable</td>
<td align="left" valign="top">Input</td>
<td align="left" valign="top">Binary(4)</td>
</tr>
<tr>
<td align="center" valign="top">3</td>
<td align="left" valign="top">Format name of receiver variable</td>
<td align="left" valign="top">Input</td>
<td align="left" valign="top">Char(8)</td>
</tr>
<tr>
<td align="center" valign="top">4</td>
<td align="left" valign="top">Error code</td>
<td align="left" valign="top">I/O</td>
<td align="left" valign="top">Char(*)</td>
</tr>
</table>
<br>
&nbsp;&nbsp;Library Name / Service Program: QSOC/QZDMMDTA<br>
<!-- iddvc RMBR -->
<br>
&nbsp;&nbsp;Default Public Authority: *EXCLUDE<br>
<!-- iddvc RMBR -->
<br>
&nbsp;&nbsp;Threadsafe: No<br>
<!-- iddvc RMBR -->
<br>
</div>
<p>The Open Stream (QzdmOpenStream) API is used to open an OptiConnect stream. The Open Stream (QzdmOpenStream) API returns a stream identifier, which is then required as input for subsequent OptiConnect APIs that require a stream identifier.</p>
<br>
<h3>Restrictions</h3>
<p>The following restrictions apply:</p>
<ul>
<li>The OptiConnect QSOC subsystem must be started on the local system prior to calling this API.<br><br></li>
<li>A maximum of 256 stream identifiers may be opened for a single job.</li>
</ul>
<br>
<h3>Authorities and Locks</h3>
<dl>
<dt><em>Service Program Authority</em></dt>
<dd>*EXECUTE</dd>
</dl>
<br>
<h3>Required Parameter Group</h3>
<dl>
<dt><strong>Receiver variable</strong></dt>
<dd>OUTPUT; CHAR(*)
<p>The receiver variable that is to receive the output control information from the Open Stream (QzdmOpenStream) API.</p>
</dd>
<dt><strong>Length of receiver variable</strong></dt>
<dd>INPUT; BINARY(4)
<p>The length of the receiver variable, in bytes. The length of the receiver variable must be at least equal to or greater than the length of the output format.</p>
</dd>
<dt><strong>Format name of receiver variable</strong></dt>
<dd>INPUT; CHAR(8)
<p>The format of the information that is returned from the Open Stream (QzdmOpenStream) API. The OSTR0100 format is used by this API for the receiver variable. See <a href="#HDROPST100">OSTR0100 Format</a> for more information on the OSTR0100 format.</p>
</dd>
<dt><strong>Error code</strong></dt>
<dd>I/O; CHAR(*)
<p>The structure in which to return error information. For the format of the structure, see <a href="../apiref/error.htm#hdrerrcod">Error Code Parameter</a>.</p>
</dd>
</dl>
<br>
<h3><a name="HDROPST100">OSTR0100 Format</a></h3>
<p>The following table defines the information returned for Format OSTR0100.</p>
<table border width="80%">
<tr>
<th align="center" valign="bottom" colspan="2">Offset</th>
<th align="left" valign="bottom" rowspan="2">Type</th>
<th align="left" valign="bottom" rowspan="2">Field</th>
</tr>
<tr>
<th align="center" valign="bottom">Dec</th>
<th align="center" valign="bottom">Hex</th>
</tr>
<tr>
<td align="center" valign="top" width="10%">0</td>
<td align="center" valign="top" width="10%">0</td>
<td align="left" valign="top" width="20%">CHAR(16)</td>
<td align="left" valign="top" width="60%">Stream identifier</td>
</tr>
</table>
<br><br>
<h3><a name="HDROPSTFLD">Field Descriptions</a></h3>
<p><strong>Stream identifier.</strong> The OptiConnect stream that is to be used for communications. This field is provided as output with the Open Stream (QzdmOpenStream) API. This field must then be provided as input on all subsequent OptiConnect API requests that require a stream identifier.</p>
<br>
<h3>Error Messages</h3>
<table width="100%" cellpadding="3">
<tr>
<th align="left" valign="top">Message ID</th>
<th align="left" valign="top">Error Message Text</th>
</tr>
<tr>
<td align="left" valign="top">CPF24B4 E</td>
<td valign="top">Severe error while addressing parameter list.</td>
</tr>
<tr>
<td align="left" valign="top">CPF3C1D E</td>
<td valign="top">Length specified in parameter &amp;1 not valid.</td>
</tr>
<tr>
<td align="left" valign="top">CPF3C21 E</td>
<td valign="top">Format name &amp;1 is not valid.</td>
</tr>
<tr>
<td align="left" valign="top">CPF3C90 E</td>
<td valign="top">Literal value cannot be changed.</td>
</tr>
<tr>
<td align="left" valign="top">CPF3CF1 E</td>
<td valign="top">Error code parameter not valid.</td>
</tr>
<tr>
<td align="left" valign="top">CPF9872 E</td>
<td valign="top">Program or service program &amp;1 in library &amp;2 ended. Reason code &amp;3.</td>
</tr>
<tr>
<td align="left" valign="top">CPFADF0 E</td>
<td valign="top">The OptiConnect QSOC subsystem must be active.</td>
</tr>
<tr>
<td align="left" valign="top">CPFADF1 E</td>
<td valign="top">OptiConnect communication error.</td>
</tr>
<tr>
<td align="left" valign="top">CPFADF5 E</td>
<td valign="top">OptiConnect API internal error, function code &amp;1, return code &amp;2.</td>
</tr>
</table>
<br>
<hr>
API introduced: V3R7
<hr>
<center>
<table cellpadding="2" cellspacing="2">
<tr align="center">
<td valign="middle" align="center"><a href="#Top_Of_Page">Top</a> |
<a href="comm.htm">Communications APIs</a> | <a href="aplist.htm">APIs by
category</a></td>
</tr>
</table>
</center>
</body>
</html>