Problem
If the current time zone (QTIMZON) system value observes daylight saving time (DST), the system automatically updates the system time for DST. If the system is also set to use other automatic adjustments for DST, more than 1 time adjustment might occur.
For example, if your time zone (QTIMZON) system value is set to Eastern Standard Time (EST), your system time will adjust 1 hour forward the first Sunday in April to observe Eastern Daylight Time (EDT). In addition, you can have the i5/OS™ job scheduler of iSeries™ Navigator set to automatically adjust the system time 1 hour forward on the first Sunday of April. With this environment, the system time adjusts a total of 2 hours forward on the first Sunday of April rather than 1 hour.
Recovery steps
If your system time was adjusted by other automatic methods (such as the i5/OS job scheduler), you need to disable the automatic adjustments and adjust the system time 1 hour to compensate for the additional hour. To do this, complete the following steps: