Instructions are given for applying Licensed Internal
Code fixes at the next unattended IPL.
To apply Licensed Internal Code that is currently operating on the
A storage area, the Licensed Internal Code fixes can be applied immediately.
- Make sure the system is in the Normal mode.
- If you are not running on the correct storage area, type the following
on any command line and press Enter:
PWRDWNSYS *IMMED RESTART(*YES)
IPLSRC(B)
- Type the following commands on any command line and press Enter
after each one:
APYPTF LICPGM(5722999) APY(*TEMP) DELAYED(*YES)
PWRDWNSYS *IMMED RESTART(*YES) IPLSRC(B)
Note: While applying Licensed Internal Code fixes, it may
be necessary for the system to reorganize a portion of the Licensed Internal
Code storage. This reorganization can take up to 1 hour. While this reorganization
is taking place, reference codes C600 434B and C600 435B are displayed.