Use this field-level keyword to specify the precision of a floating-point field.
FLTPCN(*SINGLE | *DOUBLE)
The valid parameters are *SINGLE (single precision) and *DOUBLE (double precision). This keyword is valid for floating-point fields only (data type F).
A single precision field can be up to 9 digits; a double precision field can be up to 17 digits. If you specify a field length greater than 9 (single precision) or 17 (double precision), an error message appears and the file is not created.
Option indicators are not valid for this keyword.
The following example shows how to specify the FLTPCN keyword.
|...+....1....+....2....+....3....+....4....+....5....+....6....+....7....+....8 00090A FIELDA 17F 4 1 5FLTPCN(*DOUBLE) A
FIELDA is a floating-point field with double precision.