This topic provides information about the polling interval (POLLITV)
and full inquiry interval (FULLINQITV) parameters.
The POLLITV and FULLINQITV parameters control the
exchange of information over the local management interface (LMI).
- The POLLITV parameter represents the frame-relay T391
timer. It sets the interval at which the terminal equipment (TE) sends a status
inquiry message to the frame handler (FH). You can set the POLLITV parameter
to any value between 5 and 30 seconds. The default value is 10 seconds.
- The FULLINQITV parameter represents the frame-relay N391 count. The FULLINQITV
parameter sets the interval at which the TE requests full status from the
FH. You can set the FULLINQITV parameter to any value between 1 and 255 cycles.
The default value is 6 cycles.