Example details: iSeries server to iSeries server connection using one-way automatic dialing

This example shows the matching parameters between an iSeries™ server connecting to another iSeries server using the one-way automatic-dial function. The following table describes the relationships shown in Figure 7 between the local iSeries system values and the remote iSeries values. The values shown and described here are example values.

Table 9. Local iSeries system value relationships to remote iSeries system values
Local iSeries system (B20) parameter name and value iSeries parameter value description Remote iSeries (B40) system values
Line Description: ROLE = *NEG The value for this local iSeries parameter matches the value for the remote iSeries parameter ROLE. Line Description: ROLE = *NEG
Line Description: CNN = *SWTPP The value for this local iSeries parameter matches the value for the remote iSeries parameter CNN. Line Description: CNN = *SWTPP
Line Description: CHID = 056FFFFF The value for this local iSeries parameter matches the value for the remote iSeries parameter SWTLINLST. Controller Description: CHID = 056FFFFF
Line Description: LINESPEED = 2400 The value for this local iSeries parameter matches the value for the remote iSeries parameter LINESPEED. Line Description: LINESPEED
Line Description: SWTCNN = *DIAL The value for this local iSeries parameter is related to the value for the remote iSeries parameter SWTCNN. One of the systems values must be set to *DAIL and the other to *ANS. Line Description: SWTCNN = *ANS
Line Description: AUTOANS = *NO The value for this local iSeries parameter is related to the value for the remote iSeries parameter AUTOANS. Line Description: AUTOANS = *YES
Line Description: AUTODIAL = *YES The value for this local iSeries parameter is related to the value for the remote iSeries parameter AUTODIAL. Line Description: AUTODIAL = *NO
Line Description: STNADR = B1 The value for this local iSeries parameter matches the value for the remote iSeries parameter STNADR. Line Description: STNADR = B1
Controller Description: LINKTYPE = *SDLC The value for this local iSeries parameter matches the value for the remote iSeries parameter LINKTYPE. Controller Description: LINKTYPE = *SDLC
Controller Description: SWTICHED = *YES The value for this local iSeries parameter matches the value for the remote iSeries parameter SWITCHED. Controller Description: SWITCHED = *YES
Controller Description: APPN = *NO The value for this local iSeries parameter matches the value for the remote iSeries parameter APPN. Controller Description: APPN = *NO
Controller Description: HID = 056EEEEE The value for this local iSeries parameter matches the value for the remote iSeries parameter CHID. Line Description: CHID = 056EEEEE
Controller Description: ROLE = *NEG The value for this local iSeries parameter matches the value for the remote iSeries parameter ROLE. Controller Description: ROLE = *NEG
Controller Description: STNADR = B1 The value for this local iSeries parameter matches the value for the remote iSeries parameter STNADR. Controller Description: STNADR = B1
Device Description: RMTLOCNAME = AD400BU3 The value for this local iSeries parameter matches the value for the remote iSeries parameter LCLLOCNAME. Device Description: LCLLOCNAME = AD400BU3
Device Description: LCLLOCNAME = AD400BU4 The value for this local iSeries parameter matches the value for the remote iSeries parameter RMTLOCNAME. Device Description: RMTLOCNAME = AD400BU4
Device Description: MODE = BLANK The value for this local iSeries parameter matches the value for the remote iSeries parameter MODE. Device Description: MODE = BLANK
Device Description: APPN = *NO The value for this local iSeries parameter matches the value for the remote iSeries parameter APPN. Device Description: APPN = *NO
Note: The following iSeries system parameters are related.
  • The value for the CTL parameter under Device Description corresponds to the value for the CTLD parameter under Controller Description for both iSeries systems.
  • The value for the SWTLINLST parameter under Controller Description corresponds to the value for the LIND parameter under Line Description for both iSeries systems.