The automatic installation process replaces all of the products that are currently installed and have been refreshed.
To add new products, either use the Work with Licensed Programs menu (type GO LICPGM) option 5 (Prepare for Install) before you perform these automatic installation procedures or use LICPGM menu option 11 (Install Licensed Programs) after the automatic installation. You might need to delete some products that you do not want after the installation has finished.
As you perform these steps, reference codes (also known as system reference codes or SRCs) appear on the data display of the control panel or virtual control panel of the primary partition or HMC. When the system attention light is on and a reference code starting with A6 appears, the system is waiting for you respond to a message or make a device ready. When this information lists a reference code with xx (such as A6xx 6001), it means that any combination of characters can occur where the xx appears. The console can also display reference codes during the installation of Licensed Internal Code. For more details about reference codes, refer to Reference codes for software installation.
Before you upgrade, it is required that you use the Prepare for Install options to accept online software agreements for those licensed programs (including Licensed Internal Code and the i5/OS™ operating system) that you plan to install. You must also allocate additional space for Licensed Internal Code. These tasks are described in Required: Accepting software agreements and Required: Allocating additional space for Licensed Internal Code. If these steps are not completed, the upgrade will not be completed.
If you are using image catalogs, you need to have completed steps 1 through 5 in the topic Preparing to upgrade or replace software using an image catalog. Then return to this topic. Ignore the following steps that refer to loading volumes.
To verify the image catalog entries are sorted in the correct sequence and to validate that all your images are in loaded status, enter the following command:
WRKIMGCLGE IMGCLG(catalog-name)
Ensure your catalog is in ready status and that all image catalog entries are in loaded or mounted status. To sort and verify your image catalog for installation, press PF7 to prompt for the VFYIMGCLG command. Enter *UPGRADE for the type and *YES for the sort field.
Another method to sort and verify your image catalog is to enter the following command to put the images in the correct order. By default, the volume with the lowest index is mounted. Then all the other volumes are loaded.
VFYIMGCLG IMGCLG(catalog-name) TYPE(*UPGRADE) SORT(*YES)After you ensure that your images are in loaded status, continue with step 3.
Keep the following installation media available for later use:
For descriptions of the optical media, refer to Media labels and their contents.
For logical partitions only |
---|
Use the virtual control panel (Work with
Partition Status display on your primary partition or partition status on
systems with HMC) to set the mode to Normal. Also, make sure that you
have already selected the alternate IPL device before performing the initial
program load (IPL) in step 8. Notes:
|
If you are using an image catalog to perform your upgrade and you performed the IPL in this step, you need to perform step 5 in Scenario: Preparing to upgrade or replace software using an image catalog and then return here to the next step.
After you have loaded and applied either of these PTFs, type the following:
PWRDWNSYS OPTION(*IMMED) RESTART(*YES) IPLSRC(*IMGCLG) IMGCLG(catalog-name)
PWRDWNSYS OPTION(*IMMED) RESTART(*YES) IPLSRC(D)
Press Enter. Powering down could take approximately 15 minutes or more for this step. The data display area of the control panel continues to display reference codes.
Press F12 (Cancel). Reference code B608 1105 appears on the control panel. Use the Common reference codes for software installation to determine how to continue.
Install Licensed Internal Code - Status Install of the Licensed Internal Code in progress. +-------------------------------------------------------+ Percent | XX % | complete +-------------------------------------------------------+ Elapsed time in minutes . . . . . . . . : x.x Please wait.
If you are using an image catalog (virtual optical device) for the upgrade, you will see status messages that indicate the progress of the Licensed Internal Code installation:
If you are using an image catalog for the upgrade and an error occurs, see Image catalog recovery for the recovery actions.
After a period of time (when the installation process starts to install the operating system), some displays appear on the console. One of the displays is called Licensed Internal Code IPL in Progress. Some of the IPL steps could take a long time (up to two hours or longer), depending on how much data recovery is required for your system. The last message shown on the IPL in Progress display should be Start the Operating System.
You might be prompted for the next volume several times during the installation process.
If you receive a message that refers to device QINDEV, first make the device ready. Then press Enter to continue.
Message ID. . . : CPI2070 i5/OS Installation Status +---------------------------------------------------+ Stage 2 | XX % | +---------------------------------------------------+ Installation Objects Stage Completed Restored 1 Creating needed profiles and libraries . . . . : X >> 2 Restoring programs to library QSYS . . . . . . : XXXXX 3 Restoring language objects to library QSYS . . : 4 Updating program table . . . . . . . . . . . . : 5 Installing database files. . . . . . . . . . . : 6 Completing i5/OS installation . . . . . . . . : i5/OS is a trademark of IBM in the United States and other countries.
Installing Licensed Programs System: XXXX Licensed programs processed . . . . . . . . . . : 0 of XXX Licensed program install in progress
The following display is an example of the display that appears during the installation process.
Installing Licensed Programs System: XXXX Licensed programs processed . . . . . . . . . . : X of XXX Licensed Program Option Description Type 5722SS1 2 Online Information 2924
This display shows which licensed programs and optional parts of licensed programs are being processed. After the *PGM objects and *LNG objects are processed, the display shows the total number of licensed programs processed.
Display Messages System: XXXX Queue . . . . . : QSYSOPR Program . . . . : *DSPMSG Library . . . : QSYS Library . . . : Severity . . . . : 95 Delivery . . . : *BREAK Type reply (if required), press Enter. Load a valid volume containing licensed programs in optical device OPT01 (X G). Reply . . . . G
Load the next media volume that contains licensed programs and continue the installation. Occasionally, you will be prompted to load the next volume after a short time has passed. This event usually happens when the licensed programs on the media are at the same level as the licensed programs already installed on your machine.
Type G and press Enter. After you load each volume, type G and press Enter. If there are no more volumes to load that contain licensed programs, or if you want to end the loading process, type X and press Enter.
If you receive the message Automatic installation not complete, sign on using QSECOFR for your user ID and go to Troubleshooting software installation problems to determine the problem.