Where allowed to run:
|
Parameters Examples Error messages |
The End CICS (ENDCICS) command will shut down a CICS control region and specifies what happens to active work being processed by that CICS control region.
All associated CICS shells (user or batch) must be shut down before the CICS control region can complete the shut down. The CICS user shells are informed of the involuntary shut down. Refer to the iSeries ENDCICSUSR CL command in order to shut down a CICS user shell without shutting down the CICS control region.
No new CICS shells can be started, that would be associated with the CICS control region being shut down, after this command is executed.
Top |
Keyword | Description | Choices | Notes |
---|---|---|---|
CTLRGN | Control region | Communications name, CICS | Optional, Positional 1 |
OPTION | How to end | *CNTRLD, *IMMED | Optional, Positional 2 |
DELAY | Delay time, if *CNTRLD | 1-99999, *NOLIMIT | Optional, Positional 3 |
Top |
The name of the CICS control region to be shut down. This can be obtained from your CICS System Administrator. The name of the CICS control region is also known as the CICS SYSID.
Top |
Identifies the method used to shut down the CICS control region.
The possible OPTION values are:
Top |
Indicates the amount of time (in seconds) that is allowed to complete the controlled CICS control region shut down. If this amount of time is exceeded and the CICS control region shut down is not complete, all associated CICS shells associated with the CICS control region are ended.
The possible DELAY values are:
Top |
Top |
Top |