Trace Exit Program for Trace TCP/IP Application command


  Required Parameter Group:

1 Trace option setting Input Char(10)
2 Application Input Char(10)
3 Error detected Output Char(10)
4 Comparison data1 Input Char(*)

  QSYSINC/H member name: ESCWCHT

Note 1: Valid only when watch for trace event facility is enabled (WCHMSG or WCHLICLOG parameters were specified)

The Trace TCP/IP Application (TRCTCPAPP) command has the capability to call a user-written program, if specified in the TRCPGM parameter. This user written program will be called in the following circumstances:

For SET(*ON), the trace program will be called:

For SET(*OFF), the trace program will be called:

For SET(*END), the trace program will be called:

Also, the Trace TCP/IP Application (TRCTCPAPP) command has the capability to watch for a specific event and end the trace when this event occurs. An event can be a message being sent to a specific message queue, history log or job log; or a LIClog. If specified in the TRCPGM parameter, the watch for trace event facility will call a user-written program at the moments specified in the Trace option setting parameter.

See the online help for more information on the TRCTCPAPP command.


Authorities and Locks

None.


Required Parameter Group

Trace option setting
INPUT; CHAR(10)

The reason indicating the moment at which the user-written program was called. The possible values are:

*ON - The collection of trace information is started, or 
- The watch for trace facility is starting1.
*OFF The collection of trace information is stopped and the trace information is written to spooled printer files of the user. 
*END Tracing is ended and all trace information is deleted. No trace information output is created.
*MSGID1 A match on a message id specified on WCHMSG parameter occurred.
*LICLOG1 A match on a LIC log specified on the WCHLICLOG parameter occurred.
*CMPDATA1 The major and minor code of a LIC log matched, but the comparison data did not.
*INTVAL1 The time interval specified on TRCPGMITV parameter is elapsed.
*WCHTIMO1 The length of time to watch specified on WCHTIMO is elapsed.

Application.
INPUT; CHAR(10)

The possible values for the "Application" parameter are the same as the values for the APP parameter on the TRCTCPAPP command. Ignored by watch for trace event facility.

Error detected
OUTPUT; CHAR(10)

Indicates if the trace event facility should stop or continue running, or if an error on the user-written program was found. The possible values are:


Comparison data
INPUT; CHAR(*)

The format of the trace information depends on the Trace option setting causing the exit program to be called. The format of the Comparison data is as follows if the Trace option setting is *MSGID:

Offset Type Field
Dec Hex
0 0 BINARY(4) Length of trace information
4 4 CHAR(7) Message ID
11 B CHAR(9) Reserved
20 14 BINARY(4) Offset to comparison data
24 18 BINARY(4) Length of comparison data
28 1C CHAR(*) Message comparison data

The format of the Comparison data is as follows if the Trace option setting is *LICLOG or *CMPDATA:

Offset Type Field
Dec Hex
0 0 BINARY(4) Length of trace information
4 4 CHAR(4) LIC Log major code
8 8 CHAR(4) LIC Log minor code
12 C CHAR(8) LIC Log identifier
20 14 BINARY(4) Offset to comparison data
24 18 BINARY(4) Length of comparison data
28 1C CHAR(*) LIC Log comparison data

The format of the Comparison data is as follows if the Trace option setting is *ON, *INTVAL or *WCHTIMO:

Offset Type Field
Dec Hex
0 0 BINARY(4) Length of trace information (always 4 at this time)

Field Descriptions

Length of trace information.  The length of the Comparison data parameter passed to the user-written exit program.

Length of comparison data.  The length of the user specified text to be compared against the event data.

LIC Log identifier. The LIC Log entry identifier of the LIC Log that occurred.

LIC Log major code. The major code of the LIC Log that occurred.

LIC Log minor code. The minor code of the LIC Log that occurred.

LIC Log comparison data. The user specified text string used to compare against the entry data of the watched for log entry.

Message ID.  The identifier of the message that occurred.

Message comparison data. The user specified text string used to compare against the entry data of the watched for message ID.

Offset to comparison data.  The offset to the field that holds the comparison data.


Related Information

See the Trace TCP/IP Application (TRCTCPAPP) command for more information.



Exit program introduced: V5R3 
Top | Communications APIs | APIs by category