Work with hardware resources (WRKHDWRSC)

The Work with Hardware Resources (WRKHDWRSC) command is used to display information on OptiConnect adapters. The adapters represent systems that are linked to this system through the shared bus or HSL environment. An adapter that is associated with this system is NOT shown.

To display the OptiConnect adapters, use the Work with Hardware Resources command. Enter the following:

WRKHDWRSC TYPE(*CSA)

WRKHDWRSC TYPE(*CSA) displays a resource for each remote system that had, at some point, an operational connection to the system on which you are entering the command.

The examples in the following sections demonstrate a four-system, dual-path configuration that shows SYSTEMA as the bus-owning system (Hub).

Figure 23. Work with Coupled Resources
                          Work with Coupled Resources
                                                             System:   SYSTEMA
Type options, press Enter.
   7=Display resource detail 
 Opt  Resource      Type-Model  Status                System     Text
      LB06                     Operational                     Host Bus
  7     SOC13        2685-000   Operational           SYSTEMB   Shared Bus Adapter
        SOC08        2683-000   Operational           SYSTEMC   Shared Bus Adap
        SOC07        2685-000   Operational           SYSTEMD   Shared Bus Adap
      LB07                     Operational                     Nonhost Bus
        SOC04        2682-000   Operational           SYSTEMD   Bus Adapter
        SOC02        2685-000   Operational           SYSTEMB   Shared Bus Adap
        SOC10        2683-000   Inoperative           SYSTEMC   Shared Bus Adap
 
                                                                   
                                                                       Bottom
       F3=Exit   F5=Refresh   F6=Print   F12=Cancel
 

Communication between two systems uses a pair of adapters: a source adapter, and a target adapter. The source adapter is the adapter to which a system is connected with optical cables. The target adapters are any remaining adapters on the shared bus that are connected to other systems. The WRKHDWRSC command does not display the source adapters to which you are optically connected. It displays the target adapters for other system adapters on the shared bus. These, in turn, represent systems to which you can communicate.

Note:
Virtual SPD adapters might also display on the Work with Coupled Resources screen. They will have an adapter type of 268B and a text description of Virtual Bus Adapter. HSL adapters will an adapter type of 268A and a text description of Nonhost Bus.

Some resources may have a status that is "Not detected". This is caused by:

Next, select option 7 to display resource details such as physical location and logical address. Fields are blank for cards that physically reside in a bus on another system. Serial numbers appear as zeros for these cards.

Figure 24. Displaying Resource Details
                            Display Resource Detail
                                                             System:   SYSTEMA
 Resource name  . . . . . . . :   SOC13
 Text . . . . . . . . . . . . :   Shared Bus Adapter
 Type-Model . . . . . . . . . :   2685-000
 Serial Number  . . . . . . . :   00-00000
 Part Number  . . . . . . . . :
 
 Physical location:
  Frame ID
  Card position
 Logical address:
  SPD bus:
   System bus                       6
   System board                     0
   System card                      1
 
 
 
 
                                                                   Bottom
 Press Enter to continue.
 
 F3=Exit   F5=Refresh   F6=Print   F12=Cancel