Journal OptiConnect transactions

If journaling transactions across the OptiConnect link is required, the connection transactions can be journaled. The journal name comes from the connection journal field of the OptiConnect mode table. All DDM connections made with remote systems are logged in this journal.

To log connection transactions, specify the journal name in the OptiConnect mode table, then create the journal. The field names in the journal are as follows:

  1. Source fully qualified job name
  2. Source system name
  3. Target fully qualified job name
  4. Target system name
  5. Mode description
  6. Time stamp

The SOCAnnnnnn job on the target system logs this information.