Stop OptiConnect

Because OptiConnect runs under the QSOC subsystem, you can end OptiConnect by shutting down QSOC. Before you end the OptiConnect subsystem on a particular system, you should make sure that there are no OptiConnect application programs that use the connection. See Tips: How to start and stop your system with OptiConnect.

If you are using remote journaling over OptiConnect on this system, end it before ending the QSOC subsystem. Remote journal jobs do not get displayed with the Work with Active Jobs (WRKACTJOB) command.

To end OptiConnect, enter the following command:

  ENDSBS QSOC *IMMED

After the ENDSBS command is issued, the time required to end the OptiConnect manager varies with the number of agent jobs to end in the subsystem. See Tips: How to start and stop your system with OptiConnect for more information on starting and stopping agent jobs. During this time, the QSOC subsystem cannot be restarted.

Note:
Ending OptiConnect on one system does not affect OptiConnect activity between other systems on the same bus.