Display OptiConnect link status (DSPOPCLNK)

To display the connection status information of the links between systems in the HSL or fiber-optic networks, use the Display OptiConnect Link Status (DSPOPCLNK) command. The Display OptiConnect Link Status screen will vary depending on your hardware configuration. If your hardware configuration includes HSL OptiConnect, the following screen will appear:

Figure 19. Display OptiConnect Link Status, Part 1
                        Display OptiConnect Link Status                         
                                                             System:   SYSTEMA  
 Type options, press Enter                                                      
   5=Display Loop Details   6=Display Connections Details                       
                                                                                
 Opt     Loop Number     Resource       HSL OptiConnect Status                  
  5         256          SB01            Active                                 
            257          SB02            Active                                 
            259          SB03            Active                                 
                                                                                
                                                                                
                                                                                
                                                                                
                                                                                
                                                                                
                                                                                
                                                                                
                                                                                
                                                                                
                                                                                
                                                                                
                                                                         Bottom 
 F3=Exit   F5=Refresh   F6=Display Optical Links   F12=Cancel                   
                                                                                
Note:
If your hardware configuration includes HSL OptiConnect, you can still access information relating to fiber-optic links by pressing the
F6=Display Optical Links
function key on the Display OptiConnect Link Status screen.

The Display Loop Details screen shows the status of a specific High Speed Link ring. It provides information on the bus adapter/port on each side of a system connection. To access this screen, type option 5:

5=Display Loop Details

in the Opt field.

Figure 20. Display Loop Details
                             Display Loop Details                              
                                                            System:   SYSTEMA  
Loop Number . :   256                                                          
                                                                               
--------From--------     ---------To---------                                  
Resource Name   Port     Resource Name   Port     Hardware Status              
BC02            C00      BC01            A01      Operational                  
BC01            A00      BC02            C01      Operational                  
                                                                               
                                                                               
                                                                               
                                                                               
                                                                               
                                                                               
                                                                               
                                                                               
                                                                               
                                                                               
                                                                               
                                                                               
                                                                               
                                                                        Bottom 
F3=Exit   F5=Refresh   F6=Display Connection Details   F12=Cancel              
                                                                               

You can also obtain information on the status of an HSL OptiConnect connection from the issuing system to another system by accessing the Display Connection Details screen. To view this screen, press the

F6=Display Connection Details

function key.

If your hardware configuration does not include HSL OptiConnect, the following screen will appear:

Figure 21. Display OptiConnect Link Status
                        Display OptiConnect Link Status
                                                             System:   SYSTEMA
                   ------Remote Optical Links-------
  System            Top         Bottom     Redundant        Remote    Connection
 Resource           Link        Link       Link             Bus           Status

  SYSTEMB
    SOC13           Active      Ready       Ready             4           Active
    SOC02           Ready       Active      Ready             5           Active
  SYSTEMC
    SOC08           Active      Ready       Down              2           Active
    SOC10           Unknown     Unknown     Unknown                       Failed
  SYSTEMD
    SOC07           Active      Ready       Ready             6           Active
    SOC04           Ready       Active      Ready             7           Active
                                                                     Bottom
 F3=Exit   F5=Refresh data   F11=Display local links   F12=Cancel
 

This Display OptiConnect Link Status screen above shows information related to remote optical links. Information can also be obtained on local optical links. To access this screen, press the:

F11=Display Local Links

function key.

Figure 22. Display OptiConnect Link Status
                        Display OptiConnect Link Status
                                                             System:   SYSTEMA
                   ------Local Optical Links-------
  System             Top         Bottom     Redundant       Remote     Connection
 Resource            Link        Link       Link            Bus           Status

  SYSTEMB
    SOC13           Active      Ready       Ready             6           Active
    SOC02           Ready       Active      Ready             7           Active
  SYSTEMC
    SOC08           Active      Ready       Down              6           Active
    SOC10           Unknown     Unknown     Unknown                       Failed
  SYSTEMD
    SOC07           Active      Ready       Ready             6           Active
    SOC04           Ready       Active      Ready             7           Active


                                                                    Bottom
 F3=Exit   F5=Refresh data   F11=Display bus owner   F12=Cancel
 

Information can also be obtained to indicate the bus owner. To access this Display OptiConnect Link Status, press the

F11=Display bus owner

function key.

The Display OptiConnect Link Status screens show the following:

You may receive a connection status message indicating some troubleshooting is required. Review the following to help with potential problems:

To print the entire Display OptiConnect Link Status screen use the Display OptiConnect Link Status DSPOPCLNK OUTPUT(*PRINT) command.