The QAUDFRCLVL system value allows you to set the number of journal
entries written to the auditing journal before the journals entry data moves
to auxiliary storage.
- Name in the character-based interface: QAUDFRCLVL
- Name in the iSeries™ Navigator
interface: maximum journal entries before writing to auxiliary storage
- Description: This system value allows you to set
the number of journal entries written to the auditing journal before the journals
entry data moves to auxiliary storage. This system value controls the amount
of auditing data that might be lost if the system ends abnormally.
- Recommended Values: *SYS provides the best auditing
performance. However, if your installation requires that no audit entries
be lost when your system ends abnormally, you must specify 1.
Specifying 1 might slow performance.
Table 1. Possible values for
the QAUDFRCLVL System ValueQAUDFRCLVL System Value |
Possible value |
*SYS |
The system determines when journal entries are written
to auxiliary storage based on internal system performance. |
number-of- records |
Specify a number between 1 and 100 to determine how
many audit entries can accumulate in memory before they are written to auxiliary
storage. The smaller the number, the greater the impact on system performance. |
Note: This system value is a restricted value. See Chapter 3:
"Security
System Values" in the Security Reference information for details
on how to restrict changes to security system values and a complete list of
the restricted system values. Also see the
System Value Finder for more information.