Configure and activate the communications protocol you have chosen
to use.
See the Supported communications protocols
for remote journals link below for more information.
After you have
configured the communications protocol, it must be active while you are using
the remote journal function. For example, if you are using the OptiConnect
for i5/OS® bus
transport method, then the OptiConnect for i5/OS subsystem, QSOC, must be active.
QSOC must be active for both the source system and the target system, and
the appropriate controllers and devices must be varied on. If you are using
a SNA communications transport, vary on the appropriate line, controller,
and devices and ensure subsystem QCMN is active on both systems. If you are
using TCP/IP, you must start TCP/IP by using the Start TCP/IP (STRTCP) command,
including the distributed data management (DDM) servers.
See the Networking
topic and OptiConnect for i5/OS for more detailed information.