Note: You cannot install PTFs directly from an image catalog
with Management Central, but you can use the copy from media function to copy
PTFs into save files from an image catalog associated with a virtual optical
device. For instructions, see
Copy fixes from media.
To
install your fixes from an image catalog, do the following steps:
- Create a virtual optical device
It is possible
that you used an image catalog that is associated with a virtual optical device
to perform a software upgrade. If you did, you do not need to
perform this step. If you do not have a virtual optical device, you must create
one.
- Create an image catalog
Create an image catalog
for the set of PTFs that you want to install. The Create Image Catalog (CRTIMGCLG)
command associates an image catalog with a target directory where the preloaded
images are loaded.
CRTIMGCLG IMGCLG(ptfcatalog) DIR('/MYCATALOGDIRECTORY') CRTDIR(*YES) TEXT(text-description)
Note: A directory can be associated with only one image catalog.
- Add an image catalog entry
You can add an
image catalog entry for each physical media that you have. You can also add
an image catalog entry for fixes that you received using FTP, for example,
you downloaded fixes from Fix Central.
- Load the image catalog
This step associates
the virtual optical device to the image catalog. Only one image catalog can
be associated with a specific virtual optical device. Type the following command
to load the image catalog:
LODIMGCLG IMGCLG(ptfcatalog) DEV(OPTVRT01) OPTION(*LOAD)
- Verify that the images are in the correct order
VFYIMGCLG IMGCLG(ptfcatalog) TYPE(*PTF) SORT(*YES)
The system puts the images in the correct order. By default, the volume
with the lowest index is mounted; all the other volumes are loaded. Use the
Work with Catalog Entries (WRKIMGCLGE) command to see the order of the images.
Note: If
you are attempting to load individual PTFs with the Load PTF (LODPTF) command,
only the PTFs on the volume set that is mounted can be loaded.
- Install PTFs from virtual optical device
To
install PTFs from an image catalog associated with a virtual optical device,
see Install fixes from media or Install cumulative PTF packages.
For the device name, enter the name of the virtual optical device that is
associated with your image catalog. All the PTFs from the images that are
either mounted or loaded will be installed.
- Delete images from image catalog
Once you
have successfully installed the fixes, you should remove the images from the
catalog with the Remove Image Catalog Entries (RMVIMGCLGE) command. If you
continue to add new images to the same image catalog without removing the
old images, PTF install processing will attempt to install the fixes from
all of the loaded images in the catalog.