You must match the iSeries™ configuration parameters with the configuration questions and sequence numbers to configure the 3174 controller. These parameters are described in the following table.
For more information about configuring the 3174 controllers, see these books:
To configure the iSeries server to a 3174 controller:
iSeries Prompt | iSeries Parameter | 3174 Configuration Questions | Notes |
---|---|---|---|
LAN remote adapter address1 | ADPTADR | 084, 106 | Ethernet Address
If the iSeries system uses an Ethernet line to connect to the 3174 controller, use table C-3 on page C-4 in "Appendix C: Local Area Network Addressing Considerations" of the Communications Configuration book to convert the value specified for question 084. Specify the converted address for the ADPTADR parameter on the CRTCTLRWS or CRTCTLAPPC command. Token-Ring Network Address of the 3174 If the iSeries server uses a Token-Ring network line to connect to the 3174 controller, values specified for question 106 and for the ADPTADR parameter on the CRTCTLRWS or CRTCTLAPPC command must match. If the iSeries server uses an Ethernet line through an 8209 LAN Bridge, see "Appendix C: Local Area Network Addressing Considerations" in the Communications Configuration book. |
Local adapter address | ADPTADR | 107 | Token-Ring Network Address
of the Gateway
If the iSeries server uses a Token-Ring network line to connect to the 3174 controller, values specified for question 107 and for the ADPTADR parameter on the CRTLINTRN command must match. If the iSeries server uses an Ethernet line through an 8209 LAN Bridge, see "Appendix C: Local Area Network Addressing Considerations" in the the Communications Configuration book, for information about specifying the ADPTADR parameter on the CRTLINETH command. |
Connection number | CNNNBR | 423 | Host DTE Address (HNAD)
For X.25 lines, the numbers specified on the CRTLINX25 command and in question 423 must match. |
368 | X.21 Switched Short-Hold
Mode Dial Number
For X.21 short-hold mode connections, the numbers specified on the CRTCTLRWS command and in question 368 must match. |
||
424 | 3174 DTE Address
For X.25 SVCs, the connection number specified on the CRTCTLRWS command and in question 424 must match. |
||
Destination service access point | DSAP | 940 | Ring Address Assignment
The value specified for the DSAP parameter on the CRTCTLRWS command must match the SAP@ specified for the 3174 on the Ring Address Assignment display. Used for token-ring only. |
Exchange identifier | EXCHID | 215 | Physical Unit Identification
For switched connections, the 5-digit hexadecimal value specified for question 215 must match the last 5 digits of the exchange identifier specified on the CRTCTLRWS command. |
Link type | LINKTYPE | 101 | Host Attachment (3174)
Values specified on the CRTCTLRWS command and for question 101 must match as follows:
|
Modem data rate select | MODEMRATE | 318 | Full- or Half-Speed Transmission
The values specified for the MODEMRATE parameter on the CRTLINSDLC and CRTLINX25 commands must match question 318 as follows:
|
Local network address | NETADR | 423 | Host DTE Address (HNAD)
For X.25 SVCs, the network address specified on the CRTLINX25 command and in question 423 must match. |
NRZI data encoding | NRZI | 313 | NRZ or NRZI Encoding
For SDLC lines only, the values specified on the CRTLINSDLC command and in question 313 must match as follows:
|
Source service access point | SSAP | 940 | Ring Address Assignment
The value specified for the SSAP parameter on the CRTCTLRWS command must match the SAP@ associated with the Ring@ (adapter address) of the iSeries system on the Ring Address Assignment display. Used for token-ring only. |
Short-hold mode | SHM | 367 | X.21 Switched Short-Hold
Mode
Values specified on the CRTCTLRWS command and in question 367 match as follows:
|
Station address | STNADR | 104 | Control Unit Address
Value specified for question 104 must match the STNADR specified on the CRTCTLRWS command. |
Switched connection | SWITCHED | 317 | Telecommunication Facilities
Values specified on the CRTLINSDLC command and in question 317 match as follows:
|
Note:
If you are using a 3174 Model 1L Gateway to connect an iSeries server to
a host server on a Token-Ring, the value specified for item 900 (Token-Ring Network Address of the Gateway) must match the value specified
for the ADPTADR parameter on the CRTCTLHOST command. |