If the PC will not be used for Operations Console, follow these
steps:
Important: Perform these steps only
after you are sure there are no problems with the twinaxial console.
- Disconnect the current console connection. To disconnect, do the
following:
- Select the configuration name (under iSeries Connection). This
is the name that Operations Console uses to refer to a specific server.
- From the Connection menu, click Disconnect.
The connection status shows Disconnecting.
- Wait for the status to show Disconnected.
- Cable the twinaxial console to the server and power on the twinaxial
console and the server.
- Perform an initial program load (IPL) to ensure there are no errors.
Then, at a later time, remove or move any hardware you planned for. When you are satisfied with your new console delete the current configuration
if you will not be using the cabled connection as a backup console. To delete
the configuration, do the following:
- Select the configuration name (under iSeries Connection).
- From the Connection menu, click Delete.
- Click Yes to confirm the deletion.
- Uninstall iSeries Access for Windows.
Power off the PC and remove any hardware and cables no longer
needed at this time. It is recommended that you power down the iSeries before
removing any cables or adapters from the iSeries.
Note: If the new console
fails to work in i5/OS™ you
may need to use another workstation to manually delete the controller and
device description associated with the old console device.