To change from an Operations Console with a local console directly
attached to a local console on a network (LAN), follow these steps on the
server using the existing console.
Note: If you need to add or move adapters to satisfy the hardware
requirements for Operations Console, do this work prior to starting these
steps.
- Access Dedicated
Service Tools (DST) or System Service Tools (SST). You must unlock
the SST option "Service tools device IDs" before it is usable.
- Select Work with System Partitions.
- Select Work with partition configuration.
- Choose Select Console Resource on the logical
partition.
- Press F9 to Change capability
filter.
- Select Any Console.
- To select the IOP that will support your intended console, do one
of the following:
- If the adapter to be used for the intended console is under the same
IOP as the previous console's adapter, the console IOP is already correctly
tagged. Go to step 8.
- If the adapter to be used for the intended console is under a different
IOP than the currently configured console, place a 1 in
front of the IOP to select it as the console IOP.
- Verify an adapter for Electronic Customer Support (ECS) and an
optional alternate console (twinaxial console only).
Note: The
selection of an alternate console only pertains when twinaxial workstations
are to be the alternate console and the console type is also twinaxial console.
The alternate console must be under a different IOP than the IOP tagged
for use by Operations Console. Operations Console cannot be used as an alternate
console.
- To verify the console IOP for ECS, perform the following steps:
Note: If you use Operations Console as your console type, you must also
tag the same IOP used for the console as the IOP for ECS.
- Press F12 until you arrive at the Work
with Partition Configuration window.
- Enter a 9 in front of the partition to
be tagged for ECS.
- Look at the symbols on the same line as the tagged console IOP
(the console tag is the < symbol) for the ECS symbol, which is the + (the
plus sign). If the + symbol is shown, the IOP is correctly tagged for ECS.
Go to step 9.
- To tag the console IOP for ECS, enter a 1 in front of
the IOP to be tagged for ECS.
Note: If you will be using Operation
Console as the intended console you should now see both a < and a + associated
with the console IOP.
- Press F3 to exit to the DST main menu.
- Select Work with DST environment.
- Select System Devices(skip this step if
using SST).
- Select Select Console.
- Select Operations Console (LAN):
- The Verify Operations Console Adapters window appears. This
is the resource found by the system to be used for your LAN connections. If
you receive the message No valid LAN adapter available you
did not satisfy the hardware requirements for Operations Console. If so, use F3 to
exit to the DST main menu, then, start this topic again at step 1.
- Press F11 to configure the adapter.
- Enter the appropriate network data.
- Press F7 to store the data.
- Press F14 to activate the adapter for
use by Operations Console.
- Press F3 until you return to the DST main
menu.
The system is now configured for use by Operations Console local
console on a network when an action is taken to search for a new console.
This could include an IPL, the native macro, or the console service
function (65+21). Do NOT take an action to switch to the new console until
you have satisfied any necessary PC configurations. If you do not plan to
use the local console directly attached configuration as a backup console,
you do not need to remove or move its adapter at this time. You may need it
to debug problems.
The iSeries system value QAUTOCFG must be set to ON.
Use one of the following to verify or set this system value on the iSeries
server:
- Use the WRKSYSVAL QAUTOCFG command.
- During a manual IPL, in the IPL Options window, select Y for Set
major system options. Then, for Enable automatic configuration,
select Y.
Continue with Configure
the PC to use the new console type when changing from a local console directly
attached to a local console on a network (LAN).