Use this topic to learn about error messages related to uninterruptible power supply.
Message ID | Message Text | Additional Information |
---|---|---|
CPF1816 | System utility power failed at &1; | |
CPF1817 | System power restored at &1; | The system power switched to the utility source. |
CPF1819 | System ending. Power failure message not monitored.
System ending for reason &3. Notes:
|
|
CPI0961 | Uninterruptible power supply no longer attached. | |
CPI0962 | The uninterruptible power supply is now attached. | |
CPI0963 | System on auxiliary power. | System is currently running on auxiliary power. |
CPI0964 | Weak-battery condition exists. | The external uninterruptible power supply or the internal battery indicates a weak-battery condition. If utility power fails during this condition, the system may begin an immediate shut down. See your uninterruptible power supply manual for more information. |
CPI0965 | Failure of battery backup feature in system unit. | There may be a failure of the battery or the battery charger for the battery backup feature in the system unit. Contact your service representative. |
CPI0966 | Failure of battery backup feature in expansion unit. | There may be a failure of the battery or the battery charger for the battery backup feature in the expansion unit. Contact your service representative. |
CPI0973 | Weak battery condition no longer exists. | The weak-battery condition for the external uninterruptible power supply or the internal battery no longer exists. See your uninterruptible power supply manual. |
CPI0974 | Uninterruptible power supply has been bypassed. | If a utility power failure occurs, the uninterruptible power supply cannot supply system power. The system will end abnormally. |
CPI0975 | Uninterruptible power supply no longer bypassed. | The uninterruptible power supply is no longer bypassed. |
CPI0976 | Notification of message &1; failed. | Unable to send &1; message to message queue &2; in library &3; specified in QUPSMSGQ system value. |
CPI0981 | Automatic IPL disabled. | Automatic IPL after utility power restored,
specified by system value QPWRRSTIPL, was disabled for one of the following
reasons:
|
CPI0994 | System power is restored. | The system power switched to the utility source at &1; The utility power failed for &2; seconds. During this time the system was not doing any application processing. If the utility power continues to fail, shut down the system (PWRDWNSYS command). |