Create the line description A (Minneapolis to Chicago)
The line used in this example is an SDLC nonswitched line. The command
used to create the line is CRTLINSDLC. The parameters specified are:
- LIND(CHICAGOL)
- The name assigned to the line description is CHICAGOL.
- RSRCNAME(LIN022)
- Specifies that the physical communications port named LIN022 is being
defined.