Change the network attributes (Chicago) in three-system network
The Change Network Attributes (CHGNETA) command sets the attributes for
the system within the network. The following attributes are defined for CHICAGO:
- LCLNETID(APPN)
- Specifies that the name of the local network is APPN. The remote locations
(NEWYORK and LOSANGEL in the example, systems A and B in Figure 6)
must specify this name as the remote network identifier (RMTNETID).
- LCLCPNAME(CHICAGO)
- Specifies that the name assigned to the local control point is CHICAGO.
The remote system specifies this name as the remote control point name (RMTCPNAME)
on the CRTCTLAPPC command.
- LCLLOCNAME(CHICAGO)
- The name of this location is CHICAGO. This name will be used for the
device description that is created by the APPN support.
- NODETYPE(*NETNODE)
- Specifies that the local system (CHICAGO) is a networking node in the
APPN network.