If the Operations Console has been configured as the primary console,
the system will start the Operations Console.
If the Operations Console has not been configured, the primary console
is a workstation that is attached to the first IOP that is capable of supporting
workstations.
In addition to the primary console, the system can assign up to two alternative
consoles. The first alternative console can only be a TWINAX workstation that
is attached to the same IOP as the primary console. The second alternative
console is a workstation that is attached to the next IOP or Input/Output
Adaptor (IOA) that is capable of supporting workstations.
The IOP that supports the console must be on the first system bus (bus
1).
If a workstation is not correctly attached to the first IOP that is capable
of attaching workstations, then the system will not assign a primary console.
The system will display a reference code on the operator's panel. In addition,
if the IPL mode is set to Manual, the system will stop.
The following information is covered here:
- Primary console workstation requirements
- Find the primary console when the system is operational
- Find the primary console when the system power is off
Primary console workstation requirements
In
order to be the primary console, the workstation must be operational and have
the correct port and address. If the workstation is a PC, it must also have
an active emulation program on the workstation.
The workstation requirements
are:
- TWINAX workstation - Port 0 Address 0
- ASCII workstation - Port 0
- PC attached to ASCII IOP or IOA
- Port 0
- PC software to emulate a 316x or 3151 terminal
- PC attached to TWINAX IOP
- Port 0 Address 0
- 5250 emulator software active on PC
- PC attached to a LocalTalk IOA (6054)
- SNAps 5250 Version 1.2 (or above) application
- Console capable selected on MacIntosh (IOA converts to Port 0 Address
0)
- PC attached to a 2609, 2612, 2699, or 2721 communications IOA
- Client Access Console cable attached to the 2609 or 2612 P2 port (part
number 46G0450 or 46G0479), 2699 (part number 21H3779), or 2721 (part number
44H7504)
- Operations Console cable attached to the 2609 or 2612 (part number 97H7555),
2699 (part number 97H7556), or 2721 (part number 97H7557) - 5250 emulation
or Rumba active on PC
Find the primary console when the system
is operational
There are three methods that can be used to find
the primary console:
Find the primary console when the
system power is off
Use one of the following methods: