Where allowed to run: All environments (*ALL) Threadsafe: No |
Parameters Examples Error messages |
The Create NetBIOS Description (CRTNTBD) command creates a NetBIOS configuration description. Configuration objects, such as network server descriptions, for IOPs that support NetBIOS can then refer to this object for their NetBIOS parameters.
More information about using this command is in the Communications Configuration book, SC41-5401 book.
Top |
Keyword | Description | Choices | Notes |
---|---|---|---|
NTBD | NetBIOS description | Name | Required, Positional 1 |
TEXT | Text 'description' | Character value, *BLANK | Optional |
FULLBUFDTG | Full buffer datagrams | *YES, *NO | Optional |
ADPWDWITV | Adaptive window interval | 0-65535, 1000 | Optional |
MAXWDWERR | Maximum window errors | 0-10, 0 | Optional |
MAXRCVDATA | Maximum receive data size | 512-16384, 4168 | Optional |
INACTTMR | Inactivity timer | 1000-65535, 30000 | Optional |
RSPTMR | Response timer | 50-65535, 500 | Optional |
ACKTMR | Acknowledgement timer | 50-65535, 200 | Optional |
MAXIN | Maximum outstanding receives | 1-127, 1 | Optional |
MAXOUT | Maximum outstanding transmits | 1-127, 1 | Optional |
QRYTMR | Query timeout | 500-10000, 500 | Optional |
NTBRTY | NetBIOS retry | 1-50, 8 | Optional |
ALWMULTACK | Allow multiple acknowledgement | *YES, *NO | Optional |
PREBLTPKT | Prebuilt message packets | 1-200, 5 | Optional |
PKTRESTART | Packet confirms for restart | 0-9999, 2 | Optional |
DLCRTY | DLC retries | 1-65535, 5 | Optional |
ETHSTD | Ethernet standard | *IEEE8023, *ETHV2 | Optional |
AUT | Authority | *CHANGE, *ALL, *USE, *EXCLUDE, *LIBCRTAUT | Optional |
Top |
Specifies the name of the NetBIOS configuration object being created.
This is a required parameter.
Top |
Specifies text that briefly describes the NetBIOS description.
Top |
Specifies whether to request the full transmit buffer size for datagrams.
Note: The size of the overhead is the sum of the sizes of the NetBIOS header (44 bytes), the LAN header (a maximum of 36 bytes), and the buffer hold overhead (a maximum of 6 bytes).
Top |
Specifies the time, in milliseconds, between runs of the adaptive window algorithm. For each link, this algorithm is used to change the values on the MAXIN and MAXOUT parameters to match the values set on the remote workstation using NetBIOS protocol. The algorithm considers the conditions of the link, including adapter receive buffers and transmission load, when changing the values.
Note: The value 0 disables the algorithm.
Top |
Specifies the number of dropped packets the adaptive window algorithm allows before decreasing the value on the MAXOUT parameter.
Top |
Specifies the maximum data size in any frame that can be received in a session. The partner in the transmission limits the size to the smaller of this specified size, or the size available in the partner's transmit buffer. NetBIOS takes into account the maximum size that is forwarded by bridges in the path.
Top |
Specifies the amount of time that a link can be inactive before the NetBIOS protocol driver checks to verify that the link is operational.
Top |
Specifies the amount of time to wait before again transmitting a link-level frame when no acknowledgement is received from the previous transmission.
Top |
Specifies the amount of time the NetBIOS protocol driver delays acknowledging a received frame, when the number of frames sent is less than the maximum specified on the MAXIN parameter.
Top |
Specifies the maximum number of NetBIOS messages packets that can be received before sending an acknowledgement.
Top |
Specifies the maximum number of NetBIOS messages packets that can be sent before expecting an acknowledgement.
Note: This parameter is used only when ADPWDWITV(0) is specified.
Top |
Specifies the time, in milliseconds, to wait between transmission retry attempts.
Top |
Specifies the number of transmission retries that are attempted at the NetBIOS level before assuming that the receiving party is not present.
Top |
Specifies whether acknowledgements for received data can be combined with requests for data.
Note: When the NetBIOS protocol driver sends and receives acknowledgements with incoming data, LAN performance is improved.
Note: Both parties to the transmission must support combining acknowledgements with data requests or this value is ignored.
Top |
Specifies the number of NetBIOS message packets that are prebuilt for each session.
Top |
Specifies the number of transmission confirmations that must be received before sending additional packets when an out-of-resource condition occurs. The NetBIOS protocol driver stops sending packets when an out-of-resource condition is received from a port.
Top |
Specifies the number of additional transmission attempts that will be made before assuming that the receiving data control link (DLC) layer is not responding.
Top |
Specifies the Ethernet standard frame type that is used for NetBIOS communication.
Top |
Specifies the authority you are giving to users who do not have specific authority for the object, who are not on an authorization list, and whose group profile or supplemental group profiles do not have specific authority for the object.
Top |
CRTNTBD NTBD(MYNETBIOS) ADPWDWITV(6000)
This command creates a NetBIOS description named MYNETBIOS specifying that the adapter window algorithm is to be run every 6000 milliseconds (6 seconds).
Top |
*ESCAPE Messages
Top |